| 2 | SUPPLY AND INSTALLATION OF SPLIT TYPE ROOM AIR CONDITIONING MACHINE OF FOLLOWING TONNAGE CAPACITY 3 STAR RATING FITTED WITH ROTARY COMPRESSER AND COOLING CAPACITY MIN. 6000KCAL/HR.,MINIMUM DISCHARGE AIR FLOW 800 CUM MTR,800 EER(W/W) 2.7-2.89. (RATES ARE INCLUSIVE OF EXTRA REFRIGERANT PIPE DRAIN PIPE CONNECTING CABLE) UPTO THE SATISFACTION OF EIC.2.0 TON (MAKE:HITACHI/VOLTAS/BLUE-STAR/DAIKIN OF 3 STAR NON-INVERTER TYPE.[SCHD:I&W DEPARTMENT,(M&E, DIRECTORATE), GOVT. OF WEST BENGAL, W.E.F. 10TH MAY, 2022, PG-118, ITEM NO.5.3 H.8.0.6]. |
| 3 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch brand(approved by EIC) fixed on Modular GI switch board with topcover plate flushed in wall incl. mending good damages to original finish [PVC casingcapping on surface and Switch board concealed]Average run 6 mtr |
| 4 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP |
| 5 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 63 A TPN |
| 6 | Supplying and fixing double door Horizontal TPN MCB Distributionboard with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision FOR earthing attachment Legrand 8 WAY ENCLOSURE (607716) |
| 7 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 8 | SCHEDULE OF RATES FOR EARTHINGINSTALLATIONS.Earthing with 50 mm dia GI pipe 3.64 mm thick x3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(b)By TATA(Medium GI pipe |
| 9 | SUPPLY,INSTALLATION,TESTING & COMMISSIONING OF SUCTION / DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0 / 1.5 / 2.0 / 3.0 TON CAPACITY INCLUDING BRAZING , NITRILE RUBBER INSULATION 6/9 MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED, COPPER TUBE-5/8\\".[SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3 H.4.4]. |
| 10 | SUPPLY,INSTALLATION,TESTING & COMMISSIONING OF SUCTION / DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0 / 1.5 / 2.0 / 3.0 TON CAPACITY INCLUDING BRAZING , NITRILE RUBBER INSULATION 6/9 MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED, COPPER TUBE-3/8\\".[SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3 H.4.2]. |
| 11 | GAS CHARGING (R410A/ECO FRIENDLY GREEN GAS) OFWINDOW / SPLIT AIR CONDITIONING UNIT INCLUDING FLUSHING OF COOLING & CONDENSING UNITS WITH NITROGEN GAS & RECTIFICATION OF LEAKAGE, REPLACEMENT OF FILTER, FLAIR NUT ETC OF 2.0 TR. [SCHD : I & W DEPARTMENT, (M & E) DIRECTORATE, W.E.F. 10TH MAY, 2022, GOVT. OF WEST BENGAL, PAGE-117, ITEM NO.-5.3 H.5.3]. |
| 12 | PROVIDING & FIXING OF ISI MARKED (IS:15778-2007) RIGIDCPVC DRAIN WATER PIPING 6 KG/SQ CM WITH FITTINGS LIKE ELBOW,SOCKET,TEE ETC & SUPPORT WITH MS HANGER ON CEILING OR RECESSED IN WALL WITH CHASING & PLASTERING WITH 6MM THICK CLOSED CELL ELASTOMERIC NITRILE RUBBER INSULATION COMPLETE IN ALL RESPECT, 25 MM DIA.[SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3 H.2(B)]. |
| 13 | ERECTION AND INSTALLATION OF BOTH COOLING ANDCONDENSING UNIT FOR 1.5 TON SAC AT RESPECTIVE LOCATION ON WALL ALONG WITH TERMINATION OF REFRIGERANT LINE AS PER DIRECTION OF EIC MENDING GOOD DAMAGED TO ORIGINAL FINISH, |
| 14 | SUPPLY, DELIVERY AND INSTALLATION OF M.S. ANGLE IRONSTRUCTURE TO PROVIDE ADEQUATE MECHANICAL SUPPORT FOR ODU AS PER DIRECTION OF EIC MENDING GOOD DAMAGE TO ORIGINAL FINISH, |
| 15 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 3 x 36/0.3 (2.5 sqmm) + 2 x 22/0.3 (1.5 sqmm) ECC |
| 16 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular typestarter brand(approved by EIC) with 25A Modular switch type DP MCB(c-curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. Please Enable Macros to View BoQ information |