| 1 | Earth work in excavation by mechanical means (hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by engineer in charge |
| 2 | Removal of excavated soil exec 1.5 km and n exc 5.0 Km and deposition where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 3 | M & L For Moorum/red bajri filling in floors or pavings, laid in layers properly Compacted in layers by Vibrator Compactor exc. 15 cm thick, spread, levelled and watered Complete all as specified and directed by Engr in charge. |
| 4 | M & L for Hardcore of gauge n exc. 63 mm Broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed |
| 5 | Supply and application of Artificial Turf used for Multi Sports, 15MM Turf. Structure: Monofilament/Curly. Dtex: 5500 Dtex: N/A ,Tape thickness: 100µm~140µm Tape thickness: N/A, Tape width: 0.7mm~0.9mm. Pile height: 15mm±1mm, Gauge: 3/16inch. Number of strands per tuft: 12 strands, Stitches per 10cm: 33±1.Stitches per m2, 69300±10% Total yarn weight: 1298g/sqm ±10%. Primary backing:PP + polyester fiber short-staple + Mesh scrim inlay. Weight:250g/sqm±10%.Secondary backing:latex backing.Weight:850g/sqm ±10% Total carpet, weight:2398g/sqm ±10% all as specified and as directed by the manufracturer and Engr in chanrge. |
| 6 | S&F VOLLEYBALL POST, Exact size - 2.54 m, Pipe size - 100 mm, Pipe shape - Round, Pipe thickness - 2.5-3.2 mm, Gauge of steel - 10 to 8 gz,all as specified and directed by the manufracturer and Engr in chanrge. |
| 7 | M&L for 125mm thick cement concrete 1:4:8 type D-2 as in sub base etc complete all as directed. |
| 8 | M&L RCC M20 ( Design Mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as directed. |
| 9 | M&L for Mild Steel TMT bars 8 mm and above dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 10 | M&L for sand filling under floor or in foundation including watering and consolidation etc complete all as directed. |
| 11 | M&L PCC 1:2:4 type C1 using 20mm graded stone aggregate as in coping including weathering throating and necessary formwork complete all as specified. |
| 12 | M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade etc complete all as directed. |
| 13 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 14 | Factorymade precast saucer drain of usefull drainage depth of 100mm. The height of drain will be made to match the side of the court along the toe-wall. This drain will channelize water till one corner of the court. |
| 15 | M&L for brick with fly ash brick old size straight of curved on plan exc 6 m mean adius built in CM 1:6 complete all as specified and as directed. |
| 16 | M & L for rendering 15 mm thick on concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement all as specified & directed |
| 17 | M & L for cement concrete type B-2, 1:2:4 as in foundation, filling and mass concrete (Using 40mm graded stone aggregate complete all as directed. |
| 18 | M&L, MS work as in post and struts in fencing including cutting top to shape as directed railing holes notching for wire etc and similar work conforming to Fe-290 Gde E 165 complete all as specified and directed. |
| 19 | S&F Plates (plain and chequered) channels square cut or notched ( ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment etc complete all as specified |
| 20 | Butt hinges of 75 mm, heavy weight, cold rolled mild steel and fixed |
| 21 | Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.Note: Weight of chain link fencing shall be assessed through a BOO convened by GE, once the material reach the site. |
| 22 | Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire. Complete all as specified and directed. |
| 23 | M&L for preparation of newly steel surface exc 10 cm and apply two coat of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed. |
| 24 | Material & labour for applying two coat of 100% premium acrylic emulsion paint having VOC Less than50gm/ltr and UV resistance as per IS 15489:2004 alkali and fugal resistance dirt resistance exterior paint of required shade (company Depot tinted) with silicon additives @1.43 Itr/sqm over and including priming coat of exterior primer applied @0,9 ltr/10 sqm over new surface and including preparationof surface complete all as specified and directed |
| 25 | Mild steel Screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with one washer and one hexagonal nut, n exc 50mm long and 5mm, complete all as specified and as directed. |
| 26 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35 Sqmm 3.5 core including testing after laid and jointed all as specified and as directed Note:- Excavation and earth work, cable protection shall be measured and paid separetely. |
| 27 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 Sqmm 4 core including testing after laid and jointed all as specified and as directed Note:- Excavation and earth work, cable protection shall be measured and paid separetely. |
| 28 | Excavation in trenches in any type of soft soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed. |
| 29 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed. |
| 30 | M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches, ducts for cable protection incliding levellling and consodilation complete all as specified and directed.Note : Punned thickness shall be measured. |
| 31 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type- 1 flat, size 250mm x 140mm x 40mm, complete all as specified and directed. |
| 32 | Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed. |
| 33 | Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete, including three core copper flexible wire of size 1.50 Sqmm for connection from street light fitting to OH line or junction box, including suitable angle / bracket for hanging of flood light, including connectors, complete all as specified and directed by Engineer -in -charge. |
| 34 | Supply and fix thermoplastic cable entry junction boxes of size 250 x 200 x 105 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 6-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed. |
| 35 | Supply, erecting & fixing of steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etc type 410 SP-31 (9.00 meters long) swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and Numbering of poles as directed including excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of size 600x600x1500mm height upto ground level and using PCC 1:2:4 B-1 for coping with size 450x450x300mm including necessary formwork complete all as specified and as directed. |
| 36 | Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including GI wire 4.0 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 32 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (a) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. |
| 37 | Supply, fixing and testing of Automatic Street light Timer Switch using combination of NATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable SMC enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 66 protection of capacity 8 KW 3 phase, current range 20 Amps per phase, 4 wire (3 separate power contactor) including all accessories and fixing arrangement all as specified and directed. |
| 38 | M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe/GI pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. (NOTE : (i) Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc). (ii) Equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor without any extra cost to the Govt. |
| 39 | Supplying and fixing in replacement of HDPE Pipe, 90 mm bore (PN 10), suitable for insertion in horizontal boring for protection of cable / croossing of cable, complete all as specified and directed. |
| 40 | Material and labour for cable route indicator made out of PCC (1:2:4) type B1 of size 60cm x 15cm x 5cm thick grouted in PCC (1:2:4) type B1 pillar fo size 30 cm x 30 x 45 cm in ground with and including necessary foam work and making on board MES 1100 Volt LT Cable with arrow indicating cable path (marking shall be engraved and colour painted), complete all as specified and directed. |
| 41 | M&L for PCC 1:4:8 type D2 (40 mm graded aggregate) for foundation work / plinth / hardstanding etc, complete all as specified and directed. |
| 42 | Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 25 x 4 mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40mm bore, light grade 7.5m long as applicable and as per plate No. 5 of SSR 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore, medium grade & copper lug etc. (f) 40mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion. |
| 43 | Supply and installation, testing & commissioning self-supporting totally enclosed factory fabricated LT bus, Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neoprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, accommodate and consisting of the following items :-(i) Aluminium bus-bar 300 Amps, supported with suitable size Porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB with Adjustable type release, 4 pole, 100Amps, 25 KA, 415 Volts, 50 Hz - 01 No. (as incomer) |
| 44 | Supply, Install, testing and commissioning of LED Display Screen (Volleyball / Basket ball Score board), P6, Outdoor type, Single Colour, score board size in foot 4 ft height x 6 ft length, display size 1280mm height x 1920mm length approx, variable character height, mannually communication, operation voltage-230V AC, Single side display board, including UPS backup minimum 45 minutes backup, complete all as specified and directed by Engr -in- Charge. Score board containing the following details :-(a) Volleyball Scoreboard (continue displaed at top of the screen).(b) Display real-time and date.(c) Display name of both Team (as per desired)(d) Display score of both team.(e) Display serving team symbol.(f) Display Nos. of set win by each team . |
| 45 | Material and labour for point wiring (Power point 15 Amps ) 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 2.5 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 2.5 sqmm modular boxes sunk on wall for mounting of any type modular switches, switch socket etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for power point controlled by one, one way switch, complete all as specifed and directed.Note :- Cost of cable provided from sub main DB to respective switch board in rooms/area shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 46 | Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the size 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm, complete all as specified and directed.Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same Make. |
| 47 | Supply and fixing for Legrand Plexo Box 3 module IP 65 Waterproof Enclosure with 16 Amp Switch and Socket (Combi Box) suitable for 16 amp 3 pin 250 volts AC suitable for modular switch boxes, complete all as specified and directed. Please Enable Macros to View BoQ information |