| 1 | Ground Development works - RR protection wall, Construction of mud Football and Badminton court |
| 2 | 2.28.1Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 3 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 4 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | 60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
| 6 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 9 | 5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 10 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 11 | 10.25.2 Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 12 | 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 13 | OD101983/2025-2026 Filling with contractor's own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every 3rd and top most layer with power roller of minimum 8 tonnes, for all leads including all lifts involved, all cost of materials, labour charges, hire charges for machineries, conveyance, etc.complete as per the direction of Engineer-in-charge. |
| 14 | OD101990/2025-2026 Supplying and stacking for measurement sieved red earth at site including royalty and carriage upto 5 k.m. lead,all labour charges for stacking, loading and unloading etc complete.(Based on CPWD 30.2.2 & 30.2.4.3) |
| 15 | OD101989/2025-2026 Supplying and stacking for measurement sieved sand at site including cost of sand and carriage upto 5 k.m. lead,all labour charges for stacking,loading and unloading etc complete.(Based on CPWD 30.2.2 & 30.2.4.3). |
| 16 | OD101988/2025-2026 Mixing departmentally supplied earth and sand in the required proportion specified or directed by the officer - in- charge including all cost of labour charges, hire charges of machineries etc. complete.(Based on CPWD 30.2.9) |
| 17 | OD101987/2025-2026 Spreading of departmentally supplied earth and sand in the required thickness as per direction of officer - in- charge including all cost of labour charges, hire charges of machineries etc. complete.(cost of earth and sand to be paid separately).(Based on CPWD 30.2.8) |
| 18 | OD101986/2025-2026 Consolidation of subgrade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc.including all cost of labour charges, hire charges ,fuel,oil etc. complete.(Based on CPWD 16.1) |
| 19 | OD102063/2025-2026 BADMINTON POST : Supply and installation of heavy duty badminton post in aluminium and steel uprights option with built in weights and floor protection pads. Base,uprights and back supports can be detached. Rate also includes wheels for easy movement, steel uprights (comes in a pair), badminton net etc. Approval shall be taken prior to supply of item. |
| 20 | OD102065/2025-2026 Supply and Installation of Fixed type 7's Football Goal Post (3.65m x 1.80m x 1.20m) made of pipe 10cm dia G.I. pipe with nylon net as per the direction of Engineer in Charge including all cost of materilas, labour charges, conveyance, etc. complete. |
| 21 | OD103364/2025-2026 Providing and laying of Interlock concrete block pavements having thickness 60mm (M35) as per drawings and technical specification clause 1504 confirming to IS 15658 and laid in required colour and pattern over and including 50 mm thick compacted bed of 6 mm metal including edge concreting for 300mm width and 150mm depth with CM35( @ 0.045 m3/m) |
| 22 | Construction of Collection pit |
| 23 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 24 | 2.26.1 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 25 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 26 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 27 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 28 | 5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 29 | OD15174/2025-2026 Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness ontop of drain in position including all labour charges and miscellaneous expenses etc complete. ( Based onMoRTH 55.25) |
| 30 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 31 | Fencing (9m height) |
| 32 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 33 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 34 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 36 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 37 | OD15095/2025-2026 Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete(Rate based on CPWD 50.10.2) |
| 38 | 16.70.1 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm |
| 39 | OD15096/2025-2026 Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the direction of Engineer in charge.(rate based on DAR 26.81) |
| 40 | 13.50.3 Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works |
| 41 | 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 42 | 24.2 Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: -( 1) The evaluational area of the scaffolding shall be measured for payment purpose,(2) The payment will be made once only for execution of all items of such works. |
| 43 | Renovation of existing Infrastructure facilities |
| 44 | 14.1.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 45 | Engaging Coolie. |
| 46 | OD102676/2025-2026 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (Rate based on DAR item no.14.46) |
| 47 | OD102679/2025-2026Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade: One or more coats on old work (Rate based on DAR item no.14.54.1) |
| 48 | Electrification Works |
| 49 | 90.15.4.11 Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 50 | 90.15.2.2 Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters |
| 51 | 90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 52 | 2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole |
| 53 | 2.10.4 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Triple pole |
| 54 | 2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 55 | 2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 56 | 90.12.10.3 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size |
| 57 | 90.12.5.39 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm |
| 58 | 90.12.5.40 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 59 | 90.12.5.42 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm |
| 60 | 90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 61 | 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 62 | 90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 63 | 9.1.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 64 | 9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 65 | 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 66 | OD19521/2025-2026 SKF OD: Supply and fixing SINTEX Box (150mmx150mmx100mm) or nearest size including MCB Rail or Connectors for giving connections including all accessories complete as required |
| 67 | OD19307/2025-2026 SKF OD : Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, with providing masonry enclosure with cover plate / FRP Earth Pit Chamber. ( but without charcoal/ coke and salt ) etc as required |
| 68 | 90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 69 | OD19577/2025-2026 SKF OD : Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type IP65/IP55, totally enclosed, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. The work shall be completed with all other accessories as per approved SLD. The firm should have CPRI Certification.INCOMER 63 A/40A, FP,18kA MCCB - 1 No.63 Amp TPN bus barsINSTRUMENTS; Surge protection device -Type 1+2 Voltage protection level should not be less than 1.5 kV , 40A 4P MCB (incoming side of SPD), 4A, C curve SP MCB- 3 Nos, RYB indication lamp.OUTGOINGS 6A to 32 A, 'C'; Curve SP MCB - 32 Nos (arranged by 4X8). |
| 70 | OD19578/2025-2026 SKF OD: Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 40 A/63A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber, inter connections, provision for CT chamber, 63 A SFU-1 no and separate cabin shall be provided in outdoor panel to accommodate VDB/DB(Min. 6Way) as per the requirement etc. as required, and including necessary supports of floor or wall mounting as required, and the panel fabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window for energy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required, The firm should have CPRI Certification. Please Enable Macros to View BoQ information |