|
| 1 | SITC of 12 mtr HighMast Light with 6*200W LED Flood Lights at Chekuthan MukkuJn. in Pallivasal Grama Panchayath ,Adimali Block under MLASDF 2023-24 of Adv.ARaja MLA |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 3 | 2.26.1Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stackedmaterials.All kinds of soil |
| 4 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size) |
| 5 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 7 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost ofcentering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarsesand :3 graded stone aggregate 20 mm nominal size |
| 8 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 9 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 mand lift up to 1.5 m. |
| 10 | 90.15.2.3Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/twosections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mmmm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension systemwith steel wire rope 5mm dia double drum winching system w and including round arm galvanizedluminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box andlighting spikes with single phase operation power tool installed inside the base compartment includingconnector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12Meters |
| 11 | 90.15.4.11Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factorgreater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer) |
| 12 | od182286/2024_2025Supply and installation of Twin unit aviation LED obstruction light with stand yellow-painted die-castaluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LEDlamp |
| 13 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using1.6mm CRCA sheet, powder coated (excluding base frame) |
| 14 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beedingsuitable for 1.60/ 2.00 mm sheet |
| 15 | od182287/2024_2025Supply and fixing of 25 A 2 Pole AC 1 rated power contactor,25 A connector, Digital Timer, suitablecopper socket,2.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO bettermann makesV25-B+C/1+ NPE (switching/lighting protection) for single phase protection |
| 16 | od182288/2024_2025Supply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switch for motorcontrol, supply and fixing flush head push button NO-NC, 1.5 sq. mm ISI marked FRLS PVCinsulated single core copper conductor cable and 2.5 sq. mm ISI marked FRLS PVC insulated singlecore copper conductor cable |
| 17 | od182289/2024_2025Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32 A 2-Way neutral linksmounted on DMC/SMC base and 2.5 sq.mm ISI marked FRLS PVC insulated single core copperconductor cable. |
| 18 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panelboard |
| 19 | 1.21.5Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.50mm |
| 20 | 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.25 amps |
| 21 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 22 | 2.10.3Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Double pole |
| 23 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 24 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 Vgrade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm |
| 25 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andprovidingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.(but without charcoal/ coke and salt ) as required. |
| 26 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray usingclamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clampsnot exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3mm GI strip |
| 27 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) |
| 28 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.3.15 mm (10 SWG) |
| 29 | 90.12.5.2Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe asrequired.2 core 6 sq mm |
| 30 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out ofHDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with allrequired accessories in ground in the existing trench50/38 mm or nearest size |
| 31 | 9.1.2Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.2 X 10 sq. mm (19mm) |
| 32 | FABRICATION,SUPPLY, CONVEYANCE AND INSTALLATION OF GRANITE BOARD INDICATING THE COST INVOLVED,COMMENCEMENT,COMPLETION AND INAUGURATION |
| 33 | ACP Sheet Name Board |
| 34 | Connection charges - KSEB |
| 35 | SITC of 8mtr Minimast Light with 6 nos.of150W LED Flood Lights at Kunjithanni Service Co operative Bank Jn. , Pallivasal GP in Adimaly Block Panchayath under MLA SDF2023-24 of Adv. A Raja MLA |
| 36 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 37 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 38 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 39 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 40 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size |
| 41 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 42 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 43 | od181106/2024_2025Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut & Bolt |
| 44 | 90.15.1.1Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mmsuitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriagesuitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4nos existing RCC foundation and junction box etc, complete 8 Meters |
| 45 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factorgreater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer) |
| 46 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using1.6mm CRCA sheet, powder coated (excluding base frame) |
| 47 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU'section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 48 | od181107/2024_2025Supply and fixing of 1 nos. of 25A 2 Pole AC 1 rated power contactor, 25A Connector, 1 nos. of Digitaltimer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductorcable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable needed. |
| 49 | od181108/2024_2025Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mountedon DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 50 | od181109/2024_2025Supply Conveyance and Installation of Surge protector device of IP 20 Mounting type : Screw, Voltage proctection level (UP), Nominal voltage : 230V, UOC: 10KV, L-N:7 KV , L-PE:7 KV,N-PE:7 KV, Nominaldischarge current (8/20): 10KA, Tottal discharge current (8/20): 60 KA, Response time: <35 ns, Ta: -10-55 |
| 51 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panelboard |
| 52 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCM DB complete with connections, testing, and commissioning etc.. as required 40 amps |
| 53 | 2.10.3Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Double pole |
| 54 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 55 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 56 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 Vgrade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm |
| 57 | 90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 Vgrade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sqmm |
| 58 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andprovidingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.(but without charcoal/ coke and salt ) as required |
| 59 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray usingclamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clampsnot exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3mm GI strip |
| 60 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required 3.15 mm copper conductor (10 SWG) |
| 61 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.3.15 mm (10 SWG) |
| 62 | 90.12.1.12Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refillingthe trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core4 sq mm |
| 63 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out ofHDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with allrequired accessories in ground in the existing trench50/38 mm or nearest size |
| 64 | od181555/2024_2025Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired. 3 X 4 sq mm (19mm) |
| 65 | 3 Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, thecommencement, completion and inauguration date etc |
| 66 | Charges for KSEB connection including all laison works (Actual Amount paid on production ofreceipt Please Enable Macros to View BoQ information |