| 1 | Dismantling concreteReinforced cement concrete |
| 2 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead |
| 3 | Disposal of Malba outside the premises loading/ unloading including all leads as desired by Engineer-in- charge |
| 4 | Credit of Steel Received from RCC due to Dismantling |
| 5 | Credit of GI barbed wire |
| 6 | 1.8 Meter High G.I. Barbed Wire Fencing 1.8meter highG.I. barbed wire fencing with 2.4 meter angle iron posts 50x50x6mm placed every 3 meters centre to centre 0.6 meter below ground level, every 15th post, end post, corner post suitably strutted and provided with 12 horizontal line sand two diagonals inter woven with horizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75m for each post complete as per technical clause 808 of MORT&H specifications |
| 7 | Chain Link Fence, 6 ft Height, 50 ft Length, 2.0 mm Diameter, Silver, Industrial Style, Steel Material, Ideal for Fencing (Weight- 30 kg) |
| 8 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 9 | Main Gate |
| 10 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres |
| 11 | Cement concrete 1:8:16 With stone aggregates 40mm gauge |
| 12 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and Plinth. |
| 13 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 14 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 15 | 20mm thick cement plaster 1:5 in two coat work |
| 16 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 17 | Iron grated doors, including pintle hinges & arrangements |
| 18 | Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position |
| 19 | Applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 20 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 21 | Providing & Supplying of Name Board Shown as \\"HI-TECH TECHNICAL DISSEMINATION CENTRE MALSIAN\\" Consisting of 5 mm thick Sun Board with Vinyl Printing complete as per specifications & drawings as per directions of Engineer-in-Charge. |
| 22 | Installation of only Name Boards at HWC with necessary screws, gatties etc,complete in all respects & as per satisfaction of Engineer-in-charge Please Enable Macros to View BoQ information |