| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All works up to plinth level: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 5 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 6 | Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 7 | Steel Modular confirming structure confirming to IS2062 Standards consisting of pillars and modules complet to the entire satisfaction of EIC. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and Medium Tensile steel bars. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Supplying and filling sand in sides of berms including carriage etc. complete in all respects to the entire satisfaction of the EIC. |
| 11 | Providing and fixing of water proofing treatment with mak poly plates regular grade 2104 waiting 1.75 kg sqm over etc. complete in all respects. As per satisfaction of EIC. |
| 12 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat : With common burnt clay F.P.S.(non modular) brick tile of class designation |
| 13 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing. |
| 14 | Providing&fixing tile facing with(0-9''x0-3'') tiles laid in cement sand mortar 1:4 in first storey upto 4 Mtr. Above plinth level complete in all respects. |
| 15 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase |
| 16 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. |
| 17 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketted pipes.110 mm diameter |
| 18 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm bend |
| 19 | 12 mm thick cement plaster 1:4. |
| 20 | 12 mm thick cement plaster 1:6. |
| 21 | Preparation of plastered surfaces for oil bound distemper including sand papering the surface, applying one coat of linseed oil and filling with approved quality filler, consisting of white lead, linseed oil varnish and chalk Mitti finishing the surface to the entire satisfaction of EIC |
| 22 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by EIC in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm i/c pointing in white cement mixed with pigment of matching shade complete. |
| 23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 24 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)For outside walls of Toilet |
| 25 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm Granite of any colour and shade. Area of slab over 0.50 sqm |
| 26 | Steel doors made up of 0.6mm thick sheet , door leaf 44mm thick, door frame of 1mm thick with honey comb. |
| 27 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern,including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 28 | Extra for P/F in position best Indian make (to the approval of the EIC) 1.25” i/d CP Flush valve (Jaquar), cp jet complete in all respects in place of low level cistern, flush pipe as mentioned in DSR 17.2.1 |
| 29 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. |
| 30 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore. |
| 31 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 32 | Providing and fixing soil, waste and vent pipes :100 mm dia Sand cast iron S & S pipe as per IS: 1729 |
| 33 | 75 mm dia Sand cast iron S & S pipe as per IS: 1729 100 mm . Sand cast iron S & S pipe as per IS: 1729 |
| 34 | Providing and fixing plain bend of required degree: |
| 35 | Providing and fixing collar :100 mm Sand cast iron S & S pipe as per IS: 1729 |
| 36 | 75 mm Sand cast iron S & S pipe as per IS: 1729 |
| 37 | cowl 100 mm Sand cast iron S & S pipe as per IS: 1729 |
| 38 | Providing and fixing drip seal joint including the cost of yarn for 100mm HCI pipes complete in all respects |
| 39 | Providing and fixing drip seal joint including the cost of yarn for 75mm hci pipes complete in all respects |
| 40 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 75 mm outlet Sand Cast Iron S&S as per IS- 1729. |
| 41 | Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :100 x 100 mm size P type With F.P.S. Bricks class designation 75 |
| 42 | Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia. |
| 43 | P/F G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work – Exposed on wall.15 mm dia. nominal bore |
| 44 | P/F G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work – Exposed on wall.25 mm dia. nominal bore |
| 45 | P/F G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work – Exposed on wall.32 mm dia. nominal bore |
| 46 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 47 | Cutting holes up to 30x30 cm in walls including making good the same: With F.P.S. Bricks |
| 48 | Cutting holes up to 15x15cm in R.C.C. floors and roofs for passingdrain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 49 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :25 mm nominal bore. |
| 50 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :32 mm nominal bore. |
| 51 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x 610 mm and 45 cm deep for single pipe line With F.P.S bricks. |
| 52 | Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With F.P.S bricks |
| 53 | Extra for depth beyond 45 cm of brick masonry chamber :For 455x610 mm size With F.P.S. Bricks |
| 54 | For 600x850 mm size With F.P.S. Bricks |
| 55 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter |
| 56 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 150 mm diameter S.W. Pipe |
| 57 | Extra for providing & fixing Mini Sensortronic concealed type flushing valve for urinal complete with installation box (jaquar) make, DC operated, CP connection complete in place of 10 ltr. Capacity automatic flushing cistern as per item DSR 17.4.3 sencor |
| 58 | P/F in position best Indian make (to the approval of the EIC) 15MM c.p. Brass extension nipple including the cost of cp flange complete in all respects. |
| 59 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support |
| 60 | P/F in position best Indian make (to the approval of the E.I.C.) Gunmetal ISI peat valve complete in all respects:- (a) Peat valve 1¼”. |
| 61 | P/F in position best Indian make (to the approval of the E.I.C.) Gunmetal ISI peat valve complete in all respects:- (a) Peat valve 1”. |
| 62 | Making water connection ½” size inc. the cot of ferrule gunmetal heavy duty ISI marked excavation, drilling, threading complete in all respects. |
| 63 | Provding and fixing water meter cover made out of M.S. Angle Frame 25mmx25mm shutter 20mmx20mm, 5mm thick M.S. sheet gauge complete. |
| 64 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 65 | Point wiring in PVC conduit, with modular type switch wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc as required.Group B(a) wiring light point 1.5mm2 |
| 66 | Point wiring in PVC conduit, with modular type switch wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc as required(b)wiring 3 pin 5A Socket in 1.5mm2 cable |
| 67 | Point wiring in PVC conduit, with modular type switch wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc as required(c) wiring FAN point 1.5mm2 |
| 68 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 69 | Double pole and neutral |
| 70 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way |
| 71 | Prov. & Fixing exhaust fan 12\\" of reputed make s.a. CROMPTON/BAJAJ heavy duty complete as per satisfaction of E.I.C. |
| 72 | Prov. & Fixing tube light fitting 4' ,1x40watt mirtola type USHA/ Havells / PHILIPS make complete in all respects as per satisfaction of E.I.C. |
| 73 | Earthing of sheet metal/ iron clad switchews and metalic cases etc. with no. 8 SWG (4mm dia) G.I. Wire in 15mm dia GI pipe partly recessed and partly on surface compete 135cm long 50mm dia G.I. earth pipe with necessary charcoal salt mixture upto 9 mtr. (i/c boring and refilling). |
| 74 | Making suitable size wall niche including cement plastering from inside of niche for sheet metal, iron clad switch gear : |
| 75 | Providing and Fixing of flip up stainless steel grab bar rails Hand support for handicapped person including all fitting accessories complete in all respect. |
| 76 | Providing and fixing of Anti Skid Toilet Mat| of standard size. |
| 77 | Providing and fixing aluminum 16 gauge (minimum anodic coating of grade AC.15) revolving doors of standard size including cost of chowkat and including the cost of fittings handles stopper, glass complete in all respects. As per satisfaction of EIC |
| 78 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories& stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Please Enable Macros to View BoQ information |