| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Executive Engineer(E) PWD M-253 Name of Work:- RMO of Electrical & Mechanical installations of different GNCTD offices under EMD M-253:Sub-Div M-2535, Delhi (SH:-Day to day running maintenance of all E&M installations) NIT No.:121/EE(E)/PWD M-253/2025-26 Estimated Cost:-30,67,451/- Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Sub Head Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | SH-I: Maintenance of EIDay to day Maintenance of all internal and external electrical and mechanical installation at various location by attending all types of day to day complaints i/c preventive maintenance, breakdown maintenance, replacement of all consumables etc. by deputing following qualified & experienced staff on all working days of the month excluding sunday & Holidays etc complete as per direction of Engineer-in-Charge.a) 01No. wireman in general shift b) 01 No khallasi in general shift |
| 3 | Supply of following material / accessories to match with existing installation for replacement under day to day maintenance by using existing manpower as per item No. 1 etc. as required. (Record of physical consumption shall be maintained by the contractor in requisit proforma)5/6 amps switch Piano type |
| 4 | 3 pin 5/6 A socket outlet Piano type |
| 5 | 15/16 A switch Piano type |
| 6 | 6 pin 15/16 A socket outlet Piano type |
| 7 | 5/6 A switch Modular type |
| 8 | 3 pin 5/6 A socket outlet Modular type |
| 9 | 15/16 A switch Modular type |
| 10 | 6 pin 15/16 A socket outlet Modular type |
| 11 | 2 Module Stepped type Modular Fan regulator |
| 12 | 5 A to 32 A SP MCB, 240 V, 10 kA, “C” curve |
| 13 | 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable |
| 14 | 4 sq. mm FRLS PVC insulated copper conductor, single core cable |
| 15 | 2.5 Mfd Ceiling Fan Capacitor |
| 16 | 63A SPN MCB 240 V, 10 kA, “C” curve |
| 17 | 63A TPN MCB 415 V, 10 kA, “C” curve |
| 18 | 100A, 16KA, TPMCCB |
| 19 | 200 A, 25 KA,TPMCCB |
| 20 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of Powder coated die cast /Extruded aluminium Body (Thickness > 1.20mm) 36 watt |
| 21 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of CRCA Sheet Body (Thickness > 0.50 mm)36 Watt |
| 22 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) of following body materials.50 Watt |
| 23 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) of following body materials.100 Watt |
| 24 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) of following body materials.100 Watt |
| 25 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) of following body materials.150 Watt |
| 26 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) of following body materials.200 Watt |
| 27 | Ceiling fan with Brush Less Direct Current (BLDC) Motor, 1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 28 | 300mm Sweep, 1400 rpm, single phase 230 Volt heavy duty exhaust fan |
| 29 | 230mm Sweep, single phase fresh air fan |
| 30 | SH-II: Misc. E & M worksWiring for light point/ fan point/ exhaust fan point/ call ell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 31 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 32 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 33 | 3 x 4 sq. mm |
| 34 | 3 x 6 sq. mm |
| 35 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 36 | 6 Module |
| 37 | 12 Module |
| 38 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm) |
| 39 | 6 Module (200mmX75mm) |
| 40 | 12 Module (200mmX150mm) |
| 41 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 42 | 25 mm |
| 43 | Supplying & fixing of 1 HP Domestic Water motor pump set 0.75 kW, Pipe size 25 x 25 mm, 3000 RPM (Sync), 6-55 mtrs. head Range, 4280-700 Discharge Range (LPH), Single Phase with connection etc. completer as reqd. |
| 44 | Providing & laying of the following size PVC insulated PVC sheathed copper conductor flat submersible cable with the existing pipe of submersible pump etc complete as reqd.3 core X 6 Sq.mm. |
| 45 | Providing & fixing of 6mm thick PVC coated steel wire rope with the existing pipe of submersible pump etc complete as reqd. |
| 46 | Supplying and laying of Al. armoured cable one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.2 X 10 sq. mm |
| 47 | Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering3½ X 70 sq. mm |
| 48 | SH-III: AC UnitsDay-to-day maintenance of Window type AC's, Split type AC's, Water coolers / Dispensor units of different capacities (Aprox. 59 Nos.) on all working day of month excluding sundays & holidays and attending day to day complaints including servicing, rectification of defect, replacement of defective parts/components like fan blade & blower, capacitors, connectors, relay, thermostat, selector switch, wire, lugs, filters etc. (excluding compressor, PCB, coils & charging of refrigerent, cleaning of filters), repairing of PCB, as per requirement at site etc. complete as required.(March to October) |
| 49 | Supplying & replacement of following capacity reciprocating / rottery type hermetically sealed compressor complete in the existing WTAC / STAC unit i/c repairing / rejoining of copper pipes, replacement of capillary tube & strainer i/c credit for old dismentle material under buy back etc. complete as reqd.1.5 TR capacity |
| 50 | Supplying & charging Refrigerent R-22 / R-410a in the following type/capacity AC units i/c leakage testing, repairing the leakage, pressure testing, flushing the complete system, vacuumising etc complete as required.Split/Window type AC 1.5-2 TR / Watercooler/ Dispensor |
| 51 | Supplying & replacement of following defective parts / cpmponents in the existing WTAC / STAC unit / Water coolers i/c credit for old dismentle material under buy back etc. complete as reqd.Normal PCB |
| 52 | Inverter PCB |
| 53 | Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature).(a) 1.5 TR with Inverter 5 Star BEE rating |
| 54 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). (a) Inverter Type - Cooling only: 1.5 TR with 5 Star BEE Rating |
| 55 | AMC of RO cum water cooler of 50-60/80-120LPH nominal capacity i/c quaterly service, preventive maintenance, breakdown maintenance, attending day-to-day complaints, repair / replacement of all electrical & electronic spare parts, all filters excluding membrane, replacement of compressor excluding gas charging etc. complete as required. (Total- 14 Nos) |
| 56 | Supplying & replacement of following spares in the existing RO system during servicing / maintenance i/c credit for wornout filters & membranes under buy back etc complete as reqd.RO Membrane 75GPD |
| 57 | Supplying & Charging of refrigarent in the existing RO cum water cooler of 50-60/120LPH nominal capacity etc. complete as required. |
| 58 | SH-III: Credit Items under buy backCredit for dismantle of following materials i/c dismantling the same and making good the damages etc. complete as required.5/15 A switch / Socket, Regulator, fan capacitor Assorted |
| 59 | Single Pole MCB Assorted |
| 60 | SPN / DP / TP / TPN MCB / RCCB Assorted |
| 61 | 100 to 400 A TP MCCB Assorted |
| 62 | Ceiling fan /Ex Fan Assorted |
| 63 | LED Batten 2x2 fitting Assorted |
| 64 | Street light & flood light Assorted |
| 65 | 1.5/4/6 sq. mm copper conductor, single core cable |
| 66 | Window / Split AC assorted Total in Figures 3067451.0 17280.0 Thirty Lakh Sixty Seven Thousand Four Hundred & Fifty One Only Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |