| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 8 way , Double door |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 8 | b) Single pole and neutral |
| 9 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 125 A, 16 KA,TPMCCB |
| 10 | Supplying, installation, testing & commissioning of following LED highbay fixture with IP 66 & IK 07 protection pressure die cast aluminium housing capable of delivering following nominal system lumens output with a minimum 120 lumens /watt and a CRI greater than 70 . The luminaire shall have a life class of 50000 hours @L70 for a design ambient of 35 deg C . The inbuilt electronic driver shall operate at power factor > .95 of CCT 5700K minimum internal surge protection of 10 KV with toughened glass /polycarbonated cover LM 79/80 certification to be provided by the manufacturer for LED luminaire /LED chip complete with all accessories i/c dismantling the existing fitting etc. complete with all accessories etc. directly on existing pole including making connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. complete as required at site.a) Minimum 9600 lumen |
| 11 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 12 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 13 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.a) 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 14 | Supplying and Installation of heavy duty exhaust fan of 300 mm sweep 900 rpm with louvers/shutters in the existing opening i/c making the hole suitable the size of the above fan making good the damage, connection testing commisioning with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd. |
| 15 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 70 watt |
| 16 | Provision for pole/wall mounted box (300×200×105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing and fixing of following accessories on existing pole/wall with suitable arrangement as required. a) 32 Amp 5 Way connector with bakelite base. b) 6 Amp SP MCB \\"C\\" Curve (10KA)- 1 No. c)Earth Studs - 2 sets. d) 40 ×5 mm clamp with 2 Nos. 3/8\\" Nut & Bolts-1 Set as required. e) Push & Clip handle to close/open-1 No. |
| 17 | Supply of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 kV grade confirming to IS 7098 (Part-I) 1988 of following size etc. complete as required.a) 3.5x150 sq.mm |
| 18 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Above 95 sq. mm and upto 185 sq. mm |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.a) Above 95 sq. mm and upto 185 sq. mm |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.a) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 21 | Fabrication, Supplying and installation of outdoor type cubical feeder pillar of suitable size not less than 300mm deep and 0.75 mtr × 0.75 mtr made out of M.s. sheet 2mm thick duly compartmentalised having 4 strip busbars of 300Amp capacity double door with two nos. godown locking (inter lock in panel ) arrangement for protection from theft & duly fixed on M.S. angle iron frame work of size 35 mm × 35 mm × 5 mm (NS) having 45cm long legs out of which 30 cm duly grouted in cement concrete 1:2:4(1 cement :2 sand: 4 stone aggregate 20mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminium busbar & thimbles, earthing with aluminium strip & two nos. earth studs & duly painted with one coat of red oxide & two coat of suoerior quality enamel paint complete etc. as reqd i/c Supplying & Fixing of following aceessories in the cubical panel board/feeder pillar including connection testing etc. as reqd. a) 150A, 36KA, TPMCCB with spreader link ( Thermal magnetic release)- 1 No. as incomerb) 100A, 16KA TPMCCB with spreader link (Thermo magnetic release)- 1 No. as outgoingc) 63A, TP&N MCB - 2 Nos.d) Voltmeter(0-500 volt) with selector switch.e) Ammeter(0-100 Amp) with selector switch & 100/5 Amp ratio CTs.f) Indication lamps - 05 Nosg) Power contactor : 3 pole , 40 A, 415 volt (MNX-40)h) Danger notice plate- 01 No.etc. complete as required. |
| 22 | Supplying ,installation Testing & commissioning of Powder Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683: ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: -30°C to + 60°C, complete in all respect etc. complete as reqd. |
| 23 | Supplying, installation Testing & commissioning of CO2 type Fire Extinguisher ISI marked conforming to IS: 15683. Capacity 4.5 Kg. Complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature:- 30°C to +60°C, complete in all respect etc. as reqd. Please Enable Macros to View BoQ information |