| 1 | Repairing of Field Switch unit, Make-Electrotecnica, Sr. No. VCB10404 |
| 2 | Providing and fixing of test terminal block 3 phase, 4 wire as per requirement |
| 3 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 4 | Providing and fixing cable tie |
| 5 | CT, PT ratio polarity test. |
| 6 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 7 | Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 8 | Repairing of starter of auto transformer, Sr. No.- SAHAT 2320, 6.6KV, 500W, CTR-60/5 |
| 9 | Providing and fixing of glass fuse (2 Amp) |
| 10 | Providing and fixing of 16sqmm single core HT copper cable including lugs with ferrule |
| 11 | Providing and fixing of 16SQMM Copper Lug |
| 12 | CT, PT ratio polarity test. |
| 13 | Charge for overhauling and commissioning of above items including roof top cover repairing and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 14 | Painting of Starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 15 | Repairing and maintenance of panels installed at 2X750 KVA workshop Substation & Connected Feeder |
| 16 | Repairing & maintenance of Main Islolator and operated earth switch |
| 17 | Repairing and maintenance of 200 KVAR APFC Panel |
| 18 | Providing and fixing of Isolator Drive Box with fixing in both isolator handle with locking arrangement |
| 19 | Providing & fixing of 5/6 core 2.5 Sqmm copper cable with Laying in cable trench for isolator interlocking to V.C.B 50 Mt.X2 |
| 20 | Providing and fixing of Indicating Lamp 220 V AC (30 Nos. Red, 30 Nos. green, 20 Nos. Blue and 20 nos. yellow ) |
| 21 | 4 way panel at 10 MVA Main Substation |
| 22 | Providing and fixing of IDMT Relay (Make-JVS) |
| 23 | Providing and fixing of test terminal block 3 phase, 4 wire as per requirement |
| 24 | Providing and fixing of MCB 2P,10 Amp. |
| 25 | LT Breaker of Transformer-1, Make-Schneider Electric |
| 26 | Dismantling and rewiring of control circuit wiring of VCB with 2.5 Sqmm copper cable |
| 27 | Providing and fixing Voltmeter, 0-600 Volt, Analog |
| 28 | Providing and fixing of copper Lug 2.5 Sqmm |
| 29 | Providing and fixing of cable tie |
| 30 | CT, PT ratio polarity test. |
| 31 | Repairing and Maintenance of field switch unit, Make- Meditron, Sr. No. EDO722 |
| 32 | Supply and fixing of single phase failure relay |
| 33 | Providing and fixing of fibre glass sheet |
| 34 | Providing and fixing pannel window glass |
| 35 | Providing and fixing copper Lug 2.5 Sqmm |
| 36 | Providing and fixing cable tie |
| 37 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 38 | Dismantling and rewiring of control circuit wiring of V.C.B |
| 39 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 40 | Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 41 | CT, PT ratio polarity test. |
| 42 | Repairing and Maintenance of field switch unit, Make- Electrotecnica, Sr. No. VCB2883 |
| 43 | Providing and fixing of test terminal block 3 phase, 4 wire as per requirement |
| 44 | Supply and fixing of single phase failure relay |
| 45 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 46 | Providing and fixing cable tie |
| 47 | CT, PT ratio polarity test. |
| 48 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 49 | Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 50 | Repairing of starter of HT auto transformer, Sr. No.- EN/73, CTR-50/5, Make- Electroteknica |
| 51 | Providing and fixing of Amp. meter (CTR-50/5, scale 10-200 Amp) |
| 52 | Providing and fixing of Ammeter selector switch |
| 53 | Dismantling and rewiring of control circuit wiring of starter |
| 54 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 55 | Providing and fixing cable tie |
| 56 | CT, PT ratio polarity test. |
| 57 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 58 | Painting of Starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 59 | Repairing of HT DOL starter, Volt-6.6 KV, 180 W, Sr. No.- SA2040, CTR-30/5 |
| 60 | Dismantling and rewiring of control circuit wiring of starter |
| 61 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 62 | Providing and fixing copper Lug 2.5 Sqmm |
| 63 | Providing and fixing Auxiliary relay 220 V, A.C (Make-Schinder Electic ) |
| 64 | CT, PT ratio polarity test. |
| 65 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 66 | Painting of Starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 67 | Repairing and Maintenance field switch unit, make- Meditron, Sr No.- EDO721 |
| 68 | Providing and fixing of high voltage insulation tape,11 KV grade for busbar as per required color red, yellow, blue etc. |
| 69 | Supply and fixing of single phase failure relay |
| 70 | Providing and fixing of fibre glass sheet |
| 71 | Providing and fixing pannel window glass |
| 72 | Providing and fixing copper Lug 2.5 Sqmm |
| 73 | Providing and fixing cable tie |
| 74 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 75 | Dismantling and rewiring of control circuit wiring of V.C.B with spring charging motor connection. |
| 76 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 77 | Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 78 | CT, PT ratio polarity test. |
| 79 | Repairing of HT DOL starter, Volt-6.6 KV, 180 W, Sr. No.- SA2038, CTR-30/5 |
| 80 | Dismantling and rewiring of control circuit wiring of starter |
| 81 | Providing and fixing PVC copper cable 2.5 sqmm as per required color |
| 82 | Providing and fixing copper Lug 2.5 Sqmm |
| 83 | Providing and fixing of Earth leakage Relay make- Sait Mine Line (100MSec.-1000MSec.) |
| 84 | Providing and fixing Auxiliary relay 220 V, A.C (Make-Schinder Electic ) |
| 85 | CT, PT ratio polarity test. |
| 86 | Charge for overhauling and commissioning of above items and if any other installation of item required will be provided by NCL as per instruction of EIC.) |
| 87 | Painting of Starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 88 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |