| 1 | Excavation in foundations,trenches etc., in earth work in all type of soil involving pick work, jumperwork,blasting work etc and stacking the excavated soil not more than 3 mts clear from the edge of the excavation & then returning the stacked soil in 15 cm layers,when required into plinths sides of foundation etc,consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated earth as dierected within all leads & lifts as per entire satisfaction of Engineer in charge. |
| 2 | Removal of slips/debris/silt in all kind of soil(including saturated soil excluding bolders and rocky portion requiring blasting) in all leads and lifts as per the direction of Engineer-in-charge |
| 3 | Hiring of JCB for diversion of flood/flow by trenching, pits and or extracting of pipes buried under debris/slipsincluding cost of operator and POL in all leads and lifts as per the direction of Engineer-in-charge |
| 4 | Brickwork Providing second class burnt brick masonary with conventional/IS type Bricks in Cement mortar1:6 in plinth and super structure complete in all respects in all leads and lifts as per direction of Engineer-in-Charge |
| 5 | Cement plaster, 15 mm thick, in single coat of brick/concrete/stone walls for plastering upto floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth. Cement mortar 1:3 (1 Cement : 3 sand) including all carriage of materials upto all leads and lifts complete in all respects. |
| 6 | Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 40mm nominal size) excluding cost of centring & shuttering in. |
| 7 | Removal of sand, aggregate etc. from filter tank including stacking of servicable and unserviceable materials seperatly upto a lead of 20 m and lift upto 3 meters and placing back usable filter media after grading and washing complete in all respects. |
| 8 | Replacementt of filter media Providing and placing in horizontal layers filtering media duly graded, screened, washed and cleaned as specified by the Engineer-in-charge. |
| 9 | Top layer: P/L fine sand filling 750 mm thick |
| 10 | Second Layer: P/L Course Sand: under floor 150 mm thick. |
| 11 | Third layer: P/L 50 mm Bajri 6 mm to 20 mm: under floor |
| 12 | Fourth layer P/L 100 mm Bajri 20 mm to 25 mm size under floor. |
| 13 | Fifth layer: P/L 150 mm broken stones 50mm to 75 mm size: under floor: Side units |
| 14 | Cutting of G.I pipe with gas cutter complete in all respect with prop[er finish in all leads and lifts as per the satisfaction of E-in-charge. |
| 15 | 65mm dia |
| 16 | 80mm dia |
| 17 | 100mm dia |
| 18 | 125 mm dia |
| 19 | 150mm dia |
| 20 | 200 mm dia |
| 21 | 250 mm dia |
| 22 | 300 mm dia |
| 23 | Welding of GMS/MSERW pipe with circumferential butt welding joint welded sockets at both end with triple layer as per IS 816-1965(according to wall thickness of pipes with proper finish) The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts and rates shall be inclusive of all consumables, accessories etc |
| 24 | 65mm dia |
| 25 | 80mm dia |
| 26 | 100mm dia |
| 27 | 125 mm dia |
| 28 | 150mm dia |
| 29 | 200 mm dia |
| 30 | 250 mm dia |
| 31 | 300 mm dia |
| 32 | Replacement of damaged GI Pipes by laying, jointing and testing in trenches GI/MSERW pipe confirming to ISI specification i/c commissioning complete in all respect of following dia in distriabution (earth work in trenches shall be measured and paid for separately) including all leads and lifts as per the direction & satisfaction of E-in-charge. |
| 33 | 15 mm dia |
| 34 | 20 mm dia |
| 35 | 25 mm dia |
| 36 | 32mm dia |
| 37 | 40 mm dia |
| 38 | 50 mm dia |
| 39 | 65mm dia |
| 40 | 80mm dia |
| 41 | Replacement of damaged DI Pipes by Laying, jointing and testing in trenches DI pipe confirming to ISI specification i/c commissioning complete in all respect of 150 mm dia in sewerage network (earth work in trenches shall be measured and paid for separately) including all leads and lifts as per the direction & satisfaction of E-in-charge. |
| 42 | Replacement of damaged HDPEPipes by Providing,Laying, jointing and testing in trenches HDPE pipe confirming to ISI specification i/c commissioning complete in all respect of various dia in distribution network (earth work in trenches shall be measured and paid for separately) including all leads and lifts as per the direction & satisfaction of E-in-charge. |
| 43 | 40 mm dia OD PE 63 PN4 |
| 44 | 50 mm dia OD PE 63 PN4 |
| 45 | Replacement of damaged UPVC by providing, Laying, jointing and testing in trenches u-PVC pipe confirming to ISI specification i/c commissioning complete in all respect of 150 mm dia in sewerage network (earth work in trenches shall be measured and paid for separately) including all leads and lifts as per the direction & satisfaction of E-in-charge. |
| 46 | Replacement of damaged GI Union by providing & fixing of GI union heavy duty ISI marked of various dia complete in all respect i/c all leads and lifts as per satisfacation of E-in-charge. |
| 47 | 15mm dia |
| 48 | 20mm dia |
| 49 | 25mm dia |
| 50 | 32mm dia |
| 51 | 40mm dia |
| 52 | 50mm dia |
| 53 | Replacement of GI socket of following dia complete in all respect as per the entire satisfaction of Engineer-in-charge. |
| 54 | 15mm dia |
| 55 | 20mm dia |
| 56 | 25mm dia |
| 57 | 32mm dia |
| 58 | 40mm dia |
| 59 | 50mm dia |
| 60 | Replacement of damaged Gun metal gate valve of following dia complete in all respect as per satisfaction of E-in-charge. |
| 61 | 20mm dia |
| 62 | 25mm dia |
| 63 | 32mm dia |
| 64 | Replacement by supplying and fixing at site L&T / Havells make power contactor of 400 Ampere rating complete in all respect as per the direction of Engineer-in-charge including entrie carriage upto all leads and lifts complete in all respects.The item can be substituted for lower ampere ratings and the rate of similar item on last awarded rates under this Division shall be paid , if the item is executed. However, the bidder shall quote rate only for 400 ampere rating here. |
| 65 | Replacement by supplying and fixing at site L&T / Havells make power contactor of 265 Ampere rating complete in all respect as per the direction of Engineer-in-charge including entrie carriage upto all leads and lifts complete in all respects.The item can be substituted for lower ampere ratings and the rate of similar item on last awarded rates under this Division shall be paid , if the item is executed. However, the bidder shall quote rate only for 400 ampere rating here. |
| 66 | Replacement by providing and Fixing at site thermal overload relay of 250 Ampere rating of L&T / Havells make complete in all respect as per the direction of Engineer-in- charge including entrie carriage of material upto all leads and lifts complete in all respects.The item can be substituted for lower ampere ratings and the rate of similar item on last awarded rates under this Division shall be paid , if the item is executed. However, the bidder shall quote rate only for 400 ampere rating here. |
| 67 | Replacement by providing and fixing of complete internal wiring of panels complete with required wires, lugs to make the panels functional complete in all respects a sper the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts complete in all respects. |
| 68 | Replacement by providing and fixing at site Star - Delta timer of L&T / Havells make complete in all respect as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts complete in all respect. |
| 69 | Replacement by providing and fixing at site Single Phase protector of L&T /Havells make complete in all respect as per the direction of Engineer-in-Charge including entire carriage of material upto all leads and lifts complete in all respects. |
| 70 | Replacement by providing and fixing of On/Off switches of L&T /Havells make complete in all respect as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts complete in all respects. |
| 71 | Replacement by providing and fixing of Three Phase power indicator (Red, Yellow, Green) of L&T /Havells make complete in all respect as per the direction of Engineer-in-charge including entire carriage of material up to all leads and lifts complete in all respects. |
| 72 | Replacement by supplying and fixing at site 150mm2 Single Core copper Cable of L&T /Havells make complete in all respect as per the direction of Engineer-in-charge including entire carriage of material up to all leads and lifts complete in all respects. |
| 73 | Replacemnt by supply and fixing at site 150mm2 copper thimbles complete in all respect as per the direction of Engineer-in-charge including entire carriage of material up to all leads and lifts complete in all respects. |
| 74 | Replacemnt by providing and fixing MCCB of 630 A of L&T / Havells / ABB make complete in all respect Please Enable Macros to View BoQ information |