| 1 | \\"Protective Structure\\" Earthwork in excavation for foundation of structures as per technical specification including setting out removing spreading or stacking spoils with in a lead of 150 m as directed and including trimming the sides of trenches ..all complete as per direction of E-I-C. a(Depth upto 3mtr |
| 2 | Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approvedst out props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, cross-drainetc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction |
| 3 | Plum Concrete work with cement concrete 1:3:6 with 30mm down graded stone metal 40% and stone boulders of size 150mm and above placed in position as directed excluding shuttering if any. |
| 4 | Providing and laying of Filter media with granular materials / stone crushed aggregates / brick aggregates / river bed materials satisfying the requirements laid down in clause 2504.2.2 of MoRT&H Specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. |
| 5 | weep holein Brick masonsry/plan Reinforced concrete abutment wing wall |
| 6 | 2.00m span culvert Earthwork in excavation for foundation of structures as per technical specification including setting out removing spreading or stacking spoils with in a lead of 150 m as directed and including trimming the sides of trenches ..all complete as per direction of E-I-C. a(Depth upto 3mtr |
| 7 | Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction (b) Without pumping out water by manual shoring |
| 8 | Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction (a) Where staging is required |
| 9 | (II) Cement concrete with 40 mm. down graded shingles excluding shuttering.In ground floor or foundation(b) N.B. veriety (a) 1:4:8 proportion |
| 10 | Plum Concrete work with 40 % Cement Concrete with 30 mm down graded stone metal and 60% stone boulder of size 150 mm and above, placed in position as directed excluding shuttering if any. |
| 11 | Labour for laying 150 mm to 200 mm boulder soling including rough dressing hand packing and ramming down small pieces in the interstics including rolling and preparing the bed to proper level and filling up alljoints with sandy clay or earth. |
| 12 | Stone boulder 150 mm size delivered ans stacked at site. |
| 13 | Providing and laying Design Mix concrete for plain /reinforced concrete work in any part of bridge (excluding bottom plugging) with coarse aggregates of appropriate nominal size and grading, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement, as necessary, including labour, cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge and cost for quality control, sampling, testing etc. all complete but excluding cost of labour and materials for formwork & reinforcement works.(b) M-15 Grade |
| 14 | Providing and laying Design Mix concrete for plain /reinforced concrete work in any part of bridge (excluding bottom plugging) with coarse aggregates of appropriate nominal size and grading, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement, as necessary, including labour, cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge and cost for quality control, sampling, testing etc. all complete but excluding cost of labour and materials for formwork & reinforcement works.(b) M-25 Grade |
| 15 | Furnishngand placing Rainforced/Pre-stressed Cement concretre super structure as necessarya) Hight upto5m B RCC Grade M25 Using Concrete Mixer |
| 16 | Providing and laying of Filter media with granular materials / stone crushed aggregates / brick aggregates / river bed materials satisfying the requirements laid down in clause 2504.2.2 of MoRT&H Specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. |
| 17 | Providing weep hole (100mm) A.C. in walls including packing brick bats or boulder of approved quality and size at the backsides of walls etc all complete. |
| 18 | Supplying, fitting and placing HYSD bar reinforcement in Bridge Super-structure including initial straightening, straightening of coils bars,removal of loose rust (if any), cutting to requisite length bending, binding with annealed wire not less than 1 mm in size and conforming to IS 280 at every intersection hooked and bent to correct shape and placed on forms etc. including cost of black annealed wire and cost of loading, unloading, carriage of all steel materials complete as per drawing and technical specifications. |
| 19 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar, including rounding off corners or chamfering corners as directed and recking out joints or roughening of concrete surface. a) with (1:4) cement mortor (a)10mm thick plaster |
| 20 | Add 18% GST |
| 21 | Add 1 % Laboaur Cess Please Enable Macros to View BoQ information |