| 1 | Civil Works |
| 2 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 3 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 4 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 5 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | $Electrical Works |
| 9 | 90.15.3.3Supply installation testing and commissioning of Octogaonal Pole made of hot dipgalvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mmbase plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 PartIII single arm bracket 0.5mt including connector foundation bolt 4 nos fixed inexisting RCC foundation and junction box etc. complete 6 Meters |
| 10 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer) |
| 11 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 12 | OD397754/2025-2026Supply of Syntex Make Panel suitable to install Meter for electricity supply andother accessories made out of Sheet Moulding Compound (560 x 280x 150 mmsize/ nearest size) Surface mounted or recess-in wall (Indoor/Outdoor Use) One piecemouldedSMC base and SMC door with internal hinges. Knockout for wire entry, earthingbolt. Includes Contactor, MCB , Connector, Digital Timer, RCCB, HRC Fuse Basewith HRC Fuse link, 2 Way neutral links, Earth Wire, Banana Al. socket, 2.5 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 13 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 14 | 2.12.2Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 15 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |
| 16 | OD397751/2025-2026Supply and fixing of Surge protector device of IP 20,Mounting type: Screw,Voltageprotection level(UP),Nominal voltage: 230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,NPE:7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60KA, Response time :<35 ns, Ta: -10-55 |
| 17 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 18 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke andsalt ) as required |
| 19 | OD397752/2025-2026Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below groundincluding connection/ terminating with G.I. nut, bolt, spring, washer etc. asrequired. |
| 20 | 90.12.1.3Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm |
| 21 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 22 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 23 | 9.1.2Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 10 sq. mm (19mm). |
| 24 | OD397755/2025-2026Supply and fixing of Name Board of MLA, with Angles ,Flats, Square Pipe, ACPSheet (complete 4 sides) including Nut and bolt |
| 25 | OD397756/2025-2026Supply and fixing of Granite Plaque engraved with the name of MLA , name ofProject,Name of Plan, Location, Name of LSGD ,Year of Project, Estimate Costand Name of implementing agency. Please Enable Macros to View BoQ information |