Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON. |
| 2 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 3 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 4 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 5 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 6 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 7 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 8 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 9 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 10 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 11 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 12 | Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 13 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 14 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 15 | Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 16 | Supplying and erecting mains with 3x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 17 | Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 18 | Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 19 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 20 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 21 | Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. |
| 22 | Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. |
| 23 | Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. |
| 24 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 25 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 26 | Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 27 | Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete. |
| 28 | Supplying and erecting modular type Two way switch 6A / 10A (2 Module), duly erected on provided plate and box with wiring connections complete. |
| 29 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 30 | Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator. |
| 31 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 32 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 33 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 34 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 35 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. |
| 36 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected. |
| 37 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. |
| 38 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 39 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. |
| 40 | Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. |
| 41 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. |
| 42 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected. |
| 43 | Supplying and erecting modular pop up Box 8 module erected with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table. |
| 44 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 45 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 46 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 47 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 48 | Supplying and erecting rectangular shaped LED Panel Light(1200mm X 300mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 49 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 50 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 51 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 52 | Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty. |
| 53 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50 including driver with 1 year warranty. |
| 54 | Supplying and erecting condenser 4 microfarad for fluo. Fitting as per specification no FG-FG/AS7. |
| 55 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 56 | Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2. |
| 57 | Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 58 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 59 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 60 | Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 61 | Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 62 | Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 63 | Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 64 | Supplying and erecting integrated LED street light fitting 130-140W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 15600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 65 | Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 66 | Supplying and erecting integrated LED street light fitting 200W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 67 | Supplying and erecting integrated LED street light fitting 250W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 68 | Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 69 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 70 | Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 71 | Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 72 | Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 73 | Supplying and erecting integrated LED flood light fitting Max. 250W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 74 | Supplying and erecting integrated LED flood light fitting Max. 400W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 75 | Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. |
| 76 | Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT |
| 77 | Supplying and erecting Gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT |
| 78 | Supplying & erecting integral post top lantern fixtures (mushroom type) suitable for LED lamp upto 12 W consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. FG-ODF/PTL |
| 79 | Supplying & erecting integral post top lantern fixtures (globe type) suitable for LED lamp upto 12 W consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. FG-ODF/PTL |
| 80 | Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL |
| 81 | Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2. |
| 82 | Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2. |
| 83 | Supplying and erecting integrated LED Highbay Fitting 135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2. |
| 84 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 85 | Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 86 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 87 | Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 88 | Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC |
| 89 | Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC |
| 90 | Supplying and erecting Street light bracket for erection of Single fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC |
| 91 | Supplying and erecting Street light bracket for erection of Double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC |
| 92 | Supplying and erecting Control gear 1x250W for HPSV/MH lamp with all accessories for NON Integral Flood light fittings suitable for complete |
| 93 | Supplying and erecting Control gear for NON Integral Flood light fittings suitable for 1x400W HPSV/MH lamp with all accessories complete. |
| 94 | Supplying and erecting Control gear for NON Integral Flood light fittings suitable for 2x250W HPSV/MH lamp with all accessories complete. |
| 95 | Supplying and erecting Control gear for NON Integral Flood light fittings suitable for2x400W HPSV/MH lamp with all accessories complete. |
| 96 | Supplying and erecting electronic type Driver for Outdoor LED Fittings upto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 97 | Supplying and erecting electronic type Driver for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 98 | Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 99 | Supplying and erecting electronic type Driver for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 100 | Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 101 | Supplying and erecting electronic type Driver for Outdoor LED Fittings 151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 102 | Supplying & erecting 0.5W, 230V integral type LED Lamp suitable for B-22/E-27 base. |
| 103 | Supplying and erecting Pigmy /candle lamp miniature type coloured / white. |
| 104 | Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 105 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 106 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 107 | Supplying & erecting 14W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 108 | Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 109 | Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation. |
| 110 | Supplying and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 111 | Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation. |
| 112 | Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. |
| 113 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 114 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 115 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 116 | Supplying and erecting condenser 2.5 micro farad for ceiling fan |
| 117 | Supplying and erecting 12V/130Ah to 135Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. |
| 118 | Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. |
| 119 | Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete |
| 120 | Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete |
| 121 | Providing servicing of 1/1.5/2/3 TR capacity split/window air conditioning unit with all necessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit complete and submitting report to Engineer incharge. |
| 122 | Providing annual comprehensive maintenance contract for 1 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job excludes sheet metal work and plastic material. |
| 123 | Providing annual comprehensive maintenance contract for 1.5TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. |
| 124 | Providing annual comprehensive maintenance contract for 2TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. |
| 125 | Providing annual comprehensive maintenance contract for 3TR to 4.5TR split/tower/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material |
| 126 | Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1TR by new one of same capacity with guarantee for one year with provided refrigerant complete. |
| 127 | Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1.5TR by new one of same capacity with guarantee for one year with provided refrigerant complete. |
| 128 | Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2TR by new one of same capacity with guarantee for one year with provided refrigerant complete. |
| 129 | Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2.5TR to 4.5TR by new one of same capacity with guarantee for one year with provided refrigerant complete. |
| 130 | Providing flushing out cooling coil and condenser coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure, complete. |
| 131 | Providing brazing pipes and checking leakages in the split/window unit duly with dry nitrogen pressure, complete. |
| 132 | Providing replacement of unserviceable starting relay for AC unit. |
| 133 | Providing replacement of unserviceable starting capacitor for AC unit. |
| 134 | Providing replacement of unserviceable running capacitor for AC unit. |
| 135 | Providing replacement of unserviceable fan motor capacitor for AC unit. |
| 136 | Providing replacement of unserviceable PCB for AC unit upto 3TR capacity. |
| 137 | Providing repair of faulty PCB for AC unit upto 3TR capacity. |
| 138 | Supplying and installing of new fan motor for condenser for air conditioning unit |
| 139 | Supplying and installing of new fan motor for indoor unit of air conditioner up to 3TR suitable to operate on 230/250V, A.C. or 280-340V DC supply having 4 to 8 poles as per requirement. |
| 140 | Supplying and installing new fan blade outdoor unit for AC unit. |
| 141 | Providing replacement of blower of indoor unit for AC unit. |
| 142 | Providing replacement of remote of indoor unit for AC unit. |
| 143 | Providing vaccumising the airconditioner system and charging with refrigerant R32 for AC unit. |
| 144 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit. |
| 145 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 1TR window/split AC unit. |
| 146 | Providing vaccumising the airconditioner system to 200 micron and charging with R32 refrigerant for 1.5TR window/split AC unit. |
| 147 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 2TR window/split AC unit. |
| 148 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 refrigerant for 3TR window/split AC unit. |
| 149 | Providing replacement of existing unserviceable compressor of 40 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. |
| 150 | Providing replacement of existing unserviceable compressor of 60 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. |
| 151 | Providing replacement of existing unserviceable thermostat of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. |
| 152 | Supplying and erecting candle filter with filter pot for water cooler. |
| 153 | Supplying and erecting connector pipe for candle filter of water cooler. |
| 154 | Providing replacement of base tray of water cooler of any capacity. |
| 155 | Supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor. |
| 156 | Supplying and erecting two pole power contactor 230 V, 32 A for time switch complete erected on provided wooden block/ box, with necessary materials. |
| 157 | Supplying and erecting four pole power contactor 430 V, 16 A for time switch complete erected on provided wooden block/ box, with necessary materials. |
| 158 | Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. |
| 159 | Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box. |
| 160 | Supplying & erecting four pole ON LOAD change over switch, 415V, 100A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 161 | Supplying & erecting four pole ON LOAD change over switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 162 | Supplying & erecting four pole ON LOAD change over switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 163 | Supplying & erecting four pole ON LOAD change over switch, 415V, 400A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 164 | Supplying, installing, testing and commissioning C-10 battery with capacity of 12 V, 75 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessary wiring connections, nut bolts on provided stand with five years warranty as per specification no. ESD-SOL/BAT |
| 165 | Supplying, installing, testing and commissioning C-10 battery with capacity of 12 V 100 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessary wiring connections, nut bolts on provided stand with five years warranty as per specification no. ESD-SOL/BAT |
| 166 | Supplying, installing, testing and commissioning C-10 battery with capacity of 12 V, 150 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessary wiring connections, nut bolts on provided stand with five years warranty as per specification no. ESD-SOL/BAT |
| 167 | Supplying, installing, testing and commissioning C-10 battery with capacity of 12 V, 200 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessary wiring connections, nut bolts on provided stand with five years warranty as per specification no. ESD-SOL/BAT |
| 168 | Supplying, installing, testing and commissioning C-10 battery with capacity of 12 V, 300 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessary wiring connections, nut bolts on provided stand with five years warranty as per specification no. ESD-SOL/BAT |
| 169 | Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 170 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 171 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 172 | Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 173 | Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 174 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 175 | Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 176 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 177 | Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 178 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 179 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 180 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 181 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 182 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. |
| 183 | Supplying, erecting and marking triple pole isolators only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. |
| 184 | Supplying, erecting and marking triple pole isolators only switch version of miniature circuit breaker of 63A with required wiring connections and lugs etc. in provided distribution board. |
| 185 | Supplying, erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100A with required wiring connections and lugs etc. in provided distribution board. |
| 186 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. |
| 187 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board. |
| 188 | Supplying, fixing and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS |
| 189 | Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS |
| 190 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 191 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 192 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. |
| 193 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 194 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 195 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 196 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 197 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 198 | Providing, erecting & commissioning 4 pole RCCB 40A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB |
| 199 | Providing, erecting & commissioning 4 pole RCCB 63A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB |
| 200 | Providing, erecting & commissioning 4 pole RCCB 100A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB |
| 201 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 202 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 203 | Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB |
| 204 | Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness) , with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB |
| 205 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 206 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 207 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 208 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 209 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 210 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 211 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 212 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 213 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 214 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 215 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 216 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 217 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 218 | Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 219 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 220 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 221 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 222 | Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 223 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 224 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 225 | Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 226 | Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 227 | Providing & erecting 11 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 210 mm A/F, top 90 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 228 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 229 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 230 | Supplying and erecting porcelain shackle type LT medium insulator 75x115mm dia. with G.l. (shackle) strips, nuts and bolts, complete. |
| 231 | Supplying and erecting aluminium bobbin with G.l. (shackle) strip, nuts complete. |
| 232 | Supplying and erecting fibre/PVC spacers for LT overhead line 3 to 5 conductors complete erected. |
| 233 | Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. |
| 234 | Supplying and erecting 3 phase 5 core 16 sq.mm. (3x16+1x25+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC |
| 235 | Supplying and erecting 3 phase 5 core 25 sq.mm. (3x25+1x25+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC |
| 236 | Supplying and erecting 12 Way AB cable distribution box on provided pole with necessary accessories as per specification no. OH-ABC/JBS |
| 237 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 238 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 239 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 240 | Carrying out Servicing of DG set from 62.5 kVA to 200 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC |
| 241 | Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. |
| 242 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 243 | PVC Insulation Tape |
| 244 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). |
| 245 | Supplying, installing, testing and commissioning of Solar Panel with anti dust coating Comprising high efficiency Poly-Crystaline photovoltac cell 120Wp, 12V with necessary clamps and module frame on existing structure complete Module Volt (V) 12 No. of cells in serious = 36 cell size (mm) = 156.75 cell size to clerance 1% Module size (L x W x H) m min = (1012 x 982 x 35) Voc (V) = 23.15 Isc (A) = 8.38 Pmax (W)=160 Vpm(V)=18.88 Ipm (A)-847. Voltage (beta)\\" C = 0.28%, temperature coefficient of power (gamma) C= 0.38%, Nominal operating cell temperature - 45°C 12°C operating temperature range from 40°C to 85°C Junction box connector IP 68 Waterproof PPO and MC4 Compation Module Weight (Kg) 11.20 (5 years warrantee). |
| 246 | Supplying, installing, testing and commissioning of Solar Panel with anti dust coating Comprising high efficiency Poly-Crystaline photovoltac cell 250Wp, 12V with necessary clamps and module frame on existing structure complete Module Volt (V) 12 No. of cells in serious = 36 cell size (mm) = 156.75 cell size to clerance 1% Module size (L x W x H) m min = (1012 x 982 x 35) Voc (V) = 23.15 Isc (A) = 8.38 Pmax (W)=160 Vpm(V)=18.88 Ipm (A)-847. Voltage (beta)\\" C = 0.28%, temperature coefficient of power (gamma) C= 0.38%, Nominal operating cell temperature - 45°C 12°C operating temperature range from 40°C to 85°C Junction box connector IP 68 Waterproof PPO and MC4 Compation Module Weight (Kg) 11.20 (5 years warrantee). |
| 247 | Supplying, and erecting DC LED flood light fitting of 12V 14-20 W, with lens angle of 60 degrees including first 6 hr. full intensity light output and following 6 hr with half intensity light output, with lumen < 3750 colour temperature 5500K- 6500K, colour rederting index > 70. PWM charge controller efficiency>90%, LED driverefficiency>90%. Duty cycle first six hours 100%, Rest 50% light, LED external optics 145x90 degree flood light lens class IP 66, charge controller methodology three stage battery chargemonitoring algorithm maximum charging current 10 Amps, short circuit protect ion, battery over charge protections battery deep discharge protection, solar 6 22.00 panel dusk to dawn operation NTTV-4V, DTTV-6V, battery low load disconnect voltage1 1.2V battery full load disconnect voltage 13V, battery constant voltage set point 14.7V, LED indication-green off: Battery not charging PV low green on: battery charging, green flashing: battery full, Red off: battery not discharge, Red on: Battery discharge, load disconnect. |
| 248 | Supplying, and erecting DC LED flood light fitting of 12V 40-60W, with lens angle of 60 degrees including first 6 hr. full intensity light output and following 6 hr with half intensity light output, with lumen < 3750 colour temperature 5500K- 6500K, colour rederting index > 70. PWM charge controller efficiency>90%, LED driverefficiency>90%. Duty cycle first six hours 100%, Rest 50% light, LED external optics 145x90 degree flood light lens class IP 66, charge controller methodology three stage battery chargemonitoring algorithm maximum charging current 10 Amps, short circuit protect ion, battery over charge protections battery deep discharge protection, solar 6 22.00 panel dusk to dawn operation NTTV-4V, DTTV-6V, battery low load disconnect voltage1 1.2V battery full load disconnect voltage 13V, battery constant voltage set point 14.7V, LED indication-green off: Battery not charging PV low green on: battery charging, green flashing: battery full, Red off: battery not discharge, Red on: Battery discharge, load disconnect. |
| 249 | With LifeP04 battery with capacity of 12'8V-36-50 Ah suitable for backup for 3 days with 45 15A BMS, CCII having duty cycle < 3000 suitable to charge lithium cell with necessary wiring connections, with IP 65 aluminium cabinet with stand and nut bolts complete. (Nominal Voltage 12V Nominal Capacity 150Ah, Stored Energy - 1.8Kw, Cycle@ 0.5c, 80% \\"DoD<3000, Charge Voltage - 13.2, charge mode-CCTV, Standard 1', 1.00 charge current-15amp, rapid charge current- 37.5. standard discharge current 15, max charge current - 75 amp, low voltage cutoff 11.2, casing material- Aluminium, Terminal- MC4 connector, charge temp range-0-45C, Discharge temperature range-20-55C, Storage temp- 20-45C, Weight - 17 KG. and above light and battery make as per approved make in tender specification housing of Pressure die cast aluminium alloy and heat sink extruded aluminium complete. (5 Yrs Warrantee) |
| 250 | With LifeP04 battery with capacity of 12'8V-100 Ah suitable for backup for 3 days with 45 15A BMS, CCII having duty cycle < 3000 suitable to charge lithium cell with necessary wiring connections, with IP 65 aluminium cabinet with stand and nut bolts complete. (Nominal Voltage 12V Nominal Capacity 150Ah, Stored Energy - 1.8Kw, Cycle@ 0.5c, 80% \\"DoD<3000, Charge Voltage - 13.2, charge mode-CCTV, Standard 1', 1.00 charge current-15amp, rapid charge current- 37.5. standard discharge current 15, max charge current - 75 amp, low voltage cutoff 11.2, casing material- Aluminium, Terminal- MC4 connector, charge temp range-0-45C, Discharge temperature range-20-55C, Storage temp- 20-45C, Weight - 17 KG. and above light and battery make as per approved make in tender specification housing of Pressure die cast aluminium alloy and heat sink extruded aluminium complete. (5 Yrs Warrantee) |
| 251 | efficiency>90%. Duty cycle first six hours 100%, Rest 50% light, LED external optics 145x90 degree flood light lens class IP 66, charge controller methodology three stage battery charge |
| 252 | monitoring algorithm maximum charging current 10 Amps, short circuit protect ion, battery over charge protections battery deep discharge protection, solar 6 22.00 panel dusk to dawn operation NTTV-4V, DTTV-6V, battery low load disconnect voltage1 1.2V battery full load disconnect voltage 13V, battery constant voltage set point 14.7V, LED indication-green off: Battery not charging PV low green on: battery charging, green flashing: battery full, Red off: battery not discharge, Red on: Battery discharge, load disconnect. |
| 253 | Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 254 | Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 255 | Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 256 | Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. |
| 257 | Street Light Maintenance Hydraulic Vehicle/Diesel/Oprator |
| 258 | SUPPLY of man power - electrician/wireman ( technician/lineman ) for fault finding ,street light maintenance, garden maintenance, office maitenance, new light installation/replacement , mini Highmast light maintenanace.installation and replacing of street phase and underground cable, street light point on off |
| 259 | Supply of man power - ( helper ) for light cheker and to help technician/lineman |
| 260 | RSJ POLE (125 X 70) |
| 261 | LT SHACKL HARDWARE Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail