| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall tolight/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 2 | Average run 6 Mtr. |
| 3 | Average run 8 Mtr. |
| 4 | Average run 9 Mtr. |
| 5 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper ire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. On Board |
| 6 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR/PVC casing capping, (Precision make) incl. necy. fittings as required |
| 7 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 8 | 2x56/0.3 (4.0 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 9 | Supply & Fixing 240 V, 6 A, 5 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 3/4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 10 | Supply & Fixing 240 V, 16 A, 5 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 3/4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 11 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required |
| 12 | 4 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC. |
| 13 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building work. |
| 14 | 20 mm size. |
| 15 | 25 mm size. |
| 16 | Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 17 | Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing asrequired. |
| 18 | Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. |
| 19 | Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit/ inpolythene pipe embeded in wall. |
| 20 | Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. |
| 21 | Supply and Installationof Split type room air conditioning machine of following tonnage capacity 3 star rating fitted with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC..1.5 Ton (Make : Diakin/Voltas/Hitachi) 3 star non-inverter type. |
| 22 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre-approved by Engineer in charge. |
| 23 | Supply, installation, testing & commissioning of suction/ discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required. |
| 24 | Copper tube 5/8\\" . |
| 25 | Copper tube 3/8\\". |
| 26 | Providing & Fixing of ISI marked (IS : 15778 - 2007) Rigid CPVC drain water piping 6 kg/ cm2 with fittings like elbow, socket, Tee etc& support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. 20 mm dia. |
| 27 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Make L&T/ABB. |
| 28 | 4 way Enclosure. |
| 29 | Supplying and fixing 415 V 63A 4P Isolator on din rail of existing DBs and necessary connection. Make L&T/ABB |
| 30 | Supplying and fixing 6-32A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. L&T/ABB/Siemens. |
| 31 | Supplying and fixing 415 V,TP, 40A, MCB of Breaking capacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection. LEGRAND MAKE |
| 32 | Supplying and fixing 415 V 63A 3P MCB on din rail of existing DBs and necessary connection. Make L&T/ABB |
| 33 | Supplying & Fixing 2 Module GI Modular Switch Board complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. |
| 34 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 35 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 36 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. |
| 37 | Supplying of approved make wall fan oscillating type withbase, blades, guard, speed regulator etc.AC 230-250volts. 400mmsweep |
| 38 | Supply and fixing of philips Soft Glow Office compliant fully diffused recessed mounted 2'X2' false ceiling based LED light including connection by 1.5 sq mm cu wire. Make : Philips 36 Watt. |
| 39 | Supply and fixing of philips Sleek Surface Downlight, 16 watt WH, after cutting the ceiling or wall as reqd. and also mending good the damages to building works incl wiring and connection of the light by 1.5 sq mm cu wire complete. |
| 40 | Supply & fixing the powdered coated MS bracket frame for holding the 2'x2\\" LED Luminaries, cutting the gypsum false ceiling as when as required & as per direction of EIC. |
| 41 | Disconnection & dismantling the existing damged wiring with switch boards, luminaries & fans etc with the existing damaged main with submain junction box incomming & outroing telephone Connector, including making re-connection (400 Pair) with proper checkingbefore stating the civils works or as per direction of EIC. |
| 42 | Disconnection ,dismantling the existing split & window indoor & outdoor unit etc. and handed over store to work-site before stating the civils works or as per direction of EIC. |
| 43 | Fitting &re- fixing the existing 1.5 Tr. AC machine (Indoor & Outdoor Unit) on existing position and making the newconnection of inlet & outlet with drain water pipe as per direction of EIC. |
| 44 | Supply of 10 Pair cable joint connector Krone make on existing Telephone joint box as per direction EIC. |
| 45 | Gas charging (R410A/Eco Friendly Green Gas) of indow/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 2.0 Tr. |
| 46 | GST@18% on total amount |
| 47 | CESS@1% on total amount Please Enable Macros to View BoQ information |