| 1 | Picking The existing damaged cement Plastered Surface etc.complete. |
| 2 | Labour charges for MS Grill Fabrication Work including the cost of Welding, Cutting, Grinding and labour charges etc., complete.etc., complete.Welder I calss |
| 3 | Welder II class |
| 4 | III phase welding machine |
| 5 | Pug cutting machine |
| 6 | Dismantling the dameged Brick wall & Cleaning work Mason I Class |
| 7 | Mazdoor I Class |
| 8 | Mazdoor II Class |
| 9 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers |
| 10 | Plastering with CM1:3(one cement and five sand) 20mm thick10m2. |
| 11 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement Colour |
| 12 | Dadooring the colour glazed wall tiles of size 300mmx200x6mm pardon cement morter 1:2:10mm thick and pointing with white cement using 0.40kg/m2 including finishing the joints and pointing flesh with total surface etc., complete 1m2 |
| 13 | Wiring with 2x1.50 sq.mm PVC unheated SC Aluminium cable of 1100 V grade in suitable PVC rigid pipes in wall or ceiling with PVC accessories with TW switch box in flush with wall covered by hylum sheet3mm thick and painting with suitable colour of 14 SWG TC wire for light point. |
| 14 | Supplying and fixing of 48” AC ceiling fan with 300mm down rod on the existing clamp with regulator with complete set |
| 15 | Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading,transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges,etc |
| 16 | Construction of inspection chambers of following sizes with earth work excavation for foundation , 23cm thick concrete bed using 40mm brick jelly concrete in cm 1:4:8 for foundation , brick work in cm 1:6 for chamber , plastering with cm 1:3 , 12mm thick , benching , channelling , supplying and fixing 45X45cm medium weight L.S cover and frame etc.complete.., (Size 60X60) |
| 17 | Supply and Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete. Door 0.90x2.10m |
| 18 | Windows 1.20x0.90m |
| 19 | Earth work excavation in all kinds of soils except hard rock requiring blasting, inclusive of shoring, strutting and baling out water wherever necessary refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated depositing the surplus earth within compound in places as shown by the deptl.officers, clearing and leveling the site with initial lead of 10M and lift of 2M etc.Comp.SI.No.62-rate for 10m3 |
| 20 | Refilling gallery trench and filter basins with clean excavater sand free from silt and clay. |
| 21 | Supply and delivery and fixing of G.I. Pipes and specials as per IS Specification.110mm PVC. Pipe |
| 22 | 32 mm PVC. Pipe |
| 23 | 32 mm GI. Pipe |
| 24 | 25 mm PVC. Pipe |
| 25 | 110mm PVC Coupler |
| 26 | 110mm PVC Elbow |
| 27 | 32mm PVC Coupler |
| 28 | 32mm GI Elbow |
| 29 | 32mm Tee |
| 30 | 32mm Bend |
| 31 | 32mm Reducer 32mmx25mm |
| 32 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333 |
| 33 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc ,complete as per standard specification. - 10 sq.m |
| 34 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors. |
| 35 | Supply and fixing of 300mm(12\\")sweep (light duty)AC Exhaust fan complete with necessary wall opening and making good of the wall with complete,etc |
| 36 | Supply and fixing of TNEB Meter board for suitable 32A Single phase service connection, complete etc.. |
| 37 | Labour charges for over head wiring from E.B. pole to pump room by fixing 32 mm dia G.I. Pipe to the required height over roof slab of pump room as directed by E.B. authorities including fixing MS clampset ‘U’ kondi, 7/20 G.I. wire 7/20 PVC insulated, copper wire reels, TW meter board, ariel board earth plate, G.I.bolt & Nuts, PVC hose, fuse carrier etc, Complete. |
| 38 | Re-roofing with old and new Mangalore tiles inc .new lime morter borders of 23 cm *5cm intervals etc., complete 10m2 Sl No 292 (Pointing with Cement Mortar(1:3) Slabs And Tiles to full depth of Tiles, (Marble slabs,Pressed Tiles,Ornamental tiles) -10 sqm |
| 39 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 40 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M-Sand)) using II class ground moulded bricks of size 9\\" X including finishing, curing, etc., complete complying with standard 43/8\\"X 2 3/4\\" specification - 100CFT |
| 41 | Supplying erecting STEEL CENTERING for sides and soffits inc supports and strutting for plain surface such as reinforced cement concrete slasp rectangular beams tee or el beams lintels, bed blocks staircase in all floors of any height (the retrived materials should betaken back by the contractor) the payment for centering shall be given by the concrete is laid (Bottom only) |
| 42 | Reinforced Cement Concrete 1:1 1/2:3 (One Cement One and Half sand and Three aggregates) Using 20mm Gague hard broken granite jelly for foundation including consolidatiobn and dewatering for foundation wherever necessary etc., |
| 43 | Supplying and fabricating and placing of MS grills for reinforcement rate including the cost of steel for all works, the rate to include cost of steel for all works. |
| 44 | Plastering with CM1:3(one cement and five sand) 20mm thick10m2. |
| 45 | supplying of Weld Mesh |
| 46 | ADD GST 18% Please Enable Macros to View BoQ information |