Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-03-2026 | Amendment slip1 | Date | 20-03-2026 |
| Sl. No. | Item Description |
| 1 | CWSS to 645 Habitations in Sendurai, Thirumanur, Ariyalur, Alathur, Veppur Unions of Ariyalur and Perambalur District. |
| 2 | CWSS to T.Palur and 212 Habitations in T.Palur union in Ariyalur District. |
| 3 | CWSS to Nathiyanur and 20 other Habitations in Thirumanur,and Ariyalur union of Ariyalur District |
| 4 | CWSS to 29 Habitations in Thirumanur Union of Ariyalur District |
| 5 | CWSS to Jayankondam Mpty, Udayarpalayam TP (New Scheme) in Ariyalur District |
| 6 | CWSS to Jayankondam Mpty, Udayarpalayam TP and 5 other way side Habitations (Old Scheme) in Ariyalur District |
| 7 | CWSS to 227 habitations in Andimadam union, 13 wayside habitations in Jayankondam union and 10 habitations in Thirumanur union in Ariyalur District |
| 8 | CWSS TO 281 HABITATIONS IN JAYANKONDAM UNION OF ARIYALUR DISTRICT. |
| 9 | Total Basic Value |
| 10 | GST @ 18% |
| 11 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 12 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 13 | Sump Cleaning |
| 14 | Charges for cleaning the sumps of TWAD Board by clearing the sludge and disposing it to near by boundary of the sump site including baling out the sludge water by using diesel pumpset of required capacity and removing the algae and scaling by scrapping, flushing the sump finally with bleaching powder and spreading bleaching powder around the sump , etc., complete and as directed by the departmental officers |
| 15 | 6.00 LL capacity of Collection sump @ Keelapalur |
| 16 | 5.00 LL capacity of sump @ Kollapuram |
| 17 | 5.00 LL capacity of sump @ Ogalur |
| 18 | 2.50 LL capacity of sump @ Elumur |
| 19 | 2.50 LL capacity of sump @ Veppur |
| 20 | 1.00 LL capacity of sump @ Sathya Nagar |
| 21 | 1.00 LL capacity of sump @ Poyyur |
| 22 | 1.00 LL capacity of sump @ Nannai |
| 23 | 1.00 LL capacity of sump @ Puduvettakudi |
| 24 | 1.00 LL capacity of sump @ Vayalapadi |
| 25 | 1.50 LL capacity of sump @ Vayalur |
| 26 | 1.50 LL capacity of sump @ Palaiyarasamangalam |
| 27 | 1.50 LL capacity of sump @ Periyavenmani |
| 28 | 1.50 LL capacity of sump @ Kovil Palayam |
| 29 | 1.50 LL capacity of sump @ Melamathur |
| 30 | 1.50 LL capacity of sump @ Raszabath |
| 31 | 1.50 LL capacity of sump @ Kunnam |
| 32 | 1.50 LL capacity of sump @ Lakshmipuram |
| 33 | 1.50 LL capacity of sump @ Murukkankudi |
| 34 | 0.30 LL capacity of sump @ Pudupalayam |
| 35 | 0.30 LL capacity of sump @ Rettipalayam |
| 36 | 0.30 LL capacity of sump @ Malavarayanallur |
| 37 | 0.30 LL capacity of sump @ Z.Athur |
| 38 | 0.30 LL capacity of sump @ Gudalur |
| 39 | 0.30 LL capacity of sump @ Varakupadi |
| 40 | 0.20 LL capacity of sump @ Sathanur |
| 41 | 0.10 LL capacity of sump @ Aranmanaikurichi |
| 42 | 0.10 LL capacity of sump @ Karaipadi |
| 43 | Leak & Burst |
| 44 | Attending Collar Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 45 | 350mm PSC pipe |
| 46 | 500mm PSC pipe |
| 47 | Attending Minor/ Circumfrential Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 48 | 50 mm 6 ksc PVC Pipes |
| 49 | 63mm 4 ksc PVC Pipes |
| 50 | 75mm 4 ksc PVC Pipes |
| 51 | 90mm 4 ksc PVC Pipes |
| 52 | 110mm 4 ksc PVC Pipes |
| 53 | 140mm 4 ksc PVC Pipes |
| 54 | 160mm 4 ksc PVC Pipes |
| 55 | 200mm 4 ksc PVC Pipes |
| 56 | 225mm 4 ksc PVC Pipes |
| 57 | 250mm 4 ksc PVC Pipes |
| 58 | 280mm 4 ksc PVC Pipes |
| 59 | 315mm 4 ksc PVC Pipes |
| 60 | 350mm PSC pipe |
| 61 | 500mm PSC pipe |
| 62 | 500mm DI S/S Pipe |
| 63 | 350mm DI S/S Pipe |
| 64 | 300mm DI S/S Pipe |
| 65 | 250mm DI S/S Pipe |
| 66 | 250mm HDPE PN6 Pipe |
| 67 | 200mm HDPE PN6 Pipe |
| 68 | 160mm HDPE PN6 Pipe |
| 69 | 140mm HDPE PN6 Pipe |
| 70 | 110mm HDPE PN6 Pipe |
| 71 | 90mm HDPE PN6 Pipe |
| 72 | 75mm HDPE PN6 Pipe |
| 73 | 63mm HDPE PN6 Pipe |
| 74 | Attending major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 75 | 50 mm 6 ksc PVC Pipes |
| 76 | 63mm 4 ksc PVC Pipes |
| 77 | 75mm 4 ksc PVC Pipes |
| 78 | 90mm 4 ksc PVC Pipes |
| 79 | 110mm 4 ksc PVC Pipes |
| 80 | 140mm 4 ksc PVC Pipes |
| 81 | 160mm 4 ksc PVC Pipes |
| 82 | 200mm 4 ksc PVC Pipes |
| 83 | 225mm 4 ksc PVC Pipes |
| 84 | 250mm 4 ksc PVC Pipes |
| 85 | 280mm 4 ksc PVC Pipes |
| 86 | 315mm 4 ksc PVC Pipes |
| 87 | 350mm PSC pipe |
| 88 | 500mm PSC pipe |
| 89 | 500mm DI S/S Pipe |
| 90 | 350mm DI S/S Pipe |
| 91 | 300mm DI S/S Pipe |
| 92 | 250mm DI S/S Pipe |
| 93 | 250mm HDPE PN6 Pipe |
| 94 | 200mm HDPE PN6 Pipe |
| 95 | 160mm HDPE PN6 Pipe |
| 96 | 140mm HDPE PN6 Pipe |
| 97 | 110mm HDPE PN6 Pipe |
| 98 | 90mm HDPE PN6 Pipe |
| 99 | 75mm HDPE PN6 Pipe |
| 100 | 63mm HDPE PN6 Pipe |
| 101 | Above GL |
| 102 | 350 mm MS pipe |
| 103 | 500 mm MS pipe |
| 104 | Below GL |
| 105 | 350 mm MS pipe |
| 106 | 500 mm MS pipe |
| 107 | Repairs & Renewals |
| 108 | Attending rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges, taxes within the stipulated time limit etc., complete |
| 109 | Repairing and reconditioning of Motor for 125 HP VT Pumpset including all material,labour,etc |
| 110 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 111 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 112 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 113 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 114 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 115 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 116 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 117 | Transportation charges for conveying the motor from work shop to pumping Station |
| 118 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 119 | Repairing and reconditioning of Pump for 125 HP VT Pumpset including all material,labour,etc |
| 120 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 121 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 122 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 123 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 124 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 125 | Transportation charges for conveying the VT Pump bowl assembly from our work shop to Collector Well Pump room including usage of trolley along the Foot bridge and Van |
| 126 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 127 | Re errection of reconditioned stuffing box, new Head shaft, Discharge head and Motor, fixing the Rachet load bearing assembly including filling of required 90 grade oil and Connecting the 440V AC incoming Cable to the Motor Terminal and fixing new rope in the rope gland and Checking Motor Pumpset Alignment and Rotation and testing with load etc.,Complete |
| 128 | Repairing and reconditioning of Supply of materials for 125 HP VT Pumpset including all material,labour,etc |
| 129 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 130 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 131 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 132 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 133 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 134 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 135 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 136 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 137 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 138 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 139 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 140 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 141 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 142 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 143 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 144 | Attending the repair works in 11 KV/ 433 V Transformer - 315KVA |
| 145 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 146 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 147 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 148 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 149 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 150 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 151 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 152 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 153 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 154 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 155 | Charges for Eart Pit Value Checking with Certificate |
| 156 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 157 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 158 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 159 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 160 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 161 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 162 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 163 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 164 | Supply and delivery of Drop Out fuse fixing unit set |
| 165 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 166 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 167 | Supply and delivery of Silica gel |
| 168 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 169 | Repairing and reconditioning of Motor for 50HP Centrifugal Pumpset |
| 170 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 171 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 172 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 173 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 174 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 175 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 176 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 177 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 178 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 179 | Repairing and reconditioning of Pump for 50HP Centrifugal Pumpset |
| 180 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 181 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 182 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 183 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 184 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 185 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 186 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 187 | Supply and delivery of Driven End and Non Driven End bearings |
| 188 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 189 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 190 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 191 | Repairing and reconditioning of Motor for 25HP Centrifugal Pumpset |
| 192 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 193 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 194 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 195 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 196 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 197 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 198 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 199 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 200 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 201 | Repairing and reconditioning of Pump for 25HP Centrifugal Pumpset |
| 202 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 203 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 204 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 205 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 206 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 207 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 208 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 209 | Supply and delivery of Driven End and Non Driven End bearings |
| 210 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 211 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 212 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 213 | Repairing and reconditioning of Motor & Pump for 30HP Submersible Pumpset |
| 214 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 215 | Transporting the pumpset from Pump House to work shop. |
| 216 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 217 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 218 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 219 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 220 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 221 | Repairing and reconditioning of Motor & Pump for 15HP Submersible Pumpset |
| 222 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 223 | Transporting the pumpset from Pump House to work shop. |
| 224 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 225 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 226 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 227 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 228 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 229 | Repairing and reconditioning of Motor & Pump for 12.5HP Submersible Pumpset |
| 230 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 231 | Transporting the pumpset from Pump House to work shop. |
| 232 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 233 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 234 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 235 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 236 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 237 | Repairing and reconditioning of Motor & Pump for 10HP Submersible Pumpset (Total-12Nos) |
| 238 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 239 | Transporting the pumpset from Pump House to work shop. |
| 240 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 241 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 242 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 243 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 244 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 245 | Repairing and reconditioning of Motor & Pump for 7.5HP Submersible Pumpset - Total 4Nos |
| 246 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 247 | Transporting the pumpset from Pump House to work shop. |
| 248 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 249 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 250 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 251 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 252 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 253 | Repairing and reconditioning of Motor & Pump for 5HP Submersible Pumpset - Total 44 Nos |
| 254 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 255 | Transporting the pumpset from Pump House to work shop. |
| 256 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 257 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 258 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 259 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 260 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 261 | Repairing and reconditioning of Motor & Pump for 4HP & 3HP Submersible Pumpset - Total 6 Nos |
| 262 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 263 | Transporting the pumpset from Pump House to work shop. |
| 264 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 265 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 266 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 267 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 268 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 269 | Repairing and reconditioning of Motor & Pump for 2HP Submersible Pumpset - Total 36 Nos |
| 270 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 271 | Transporting the pumpset from Pump House to work shop. |
| 272 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 273 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 274 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 275 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 276 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 277 | Repairing and reconditioning of Motor & Pump for 1HP Submersible Pumpset - Total 34 Nos |
| 278 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 279 | Transporting the pumpset from Pump House to work shop. |
| 280 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 281 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 282 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 283 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 284 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 285 | Starters |
| 286 | Attending repair works in Soft starter 130 HP |
| 287 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 288 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 289 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 290 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 291 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 292 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 293 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 294 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 295 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 296 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 297 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 298 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 299 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 300 | Attending repair works in ATS starter 60 HP |
| 301 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 302 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 303 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 304 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 305 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 306 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 307 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 308 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 309 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 310 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 311 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 312 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 313 | Attending repair works in ATS starter 30 HP |
| 314 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 315 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 316 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 317 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 318 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 319 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 320 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 321 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 322 | Attending repair works in Star Delta starter 25 HP |
| 323 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 324 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 325 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 326 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 327 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 328 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 329 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 330 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 331 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 332 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 333 | Attending repair works in ATS starter 15 HP |
| 334 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 335 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 336 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 337 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 338 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 339 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 340 | Attending repair works in Star Delta starter 12.5 HP |
| 341 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 342 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 343 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 344 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 345 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 346 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 347 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 348 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 349 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 350 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 351 | Attending repair works in Star Delta starter 10 HP |
| 352 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 353 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 354 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 355 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 356 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 357 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 358 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 359 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 360 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 361 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 362 | Attending repair works in Star Delta starter 7.5 HP |
| 363 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 364 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 365 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 366 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 367 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 368 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 369 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 370 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 371 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 372 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 373 | Attending repair works in DOL starter 5 HP |
| 374 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 375 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 376 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 377 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 378 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 379 | Attending repair works in DOL starter 3 HP |
| 380 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 381 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 382 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 383 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 384 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 385 | Attending repair works in DOL starter 2 HP |
| 386 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 387 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 388 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 389 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 390 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 391 | Attending repair works in DOL starter 1 HP |
| 392 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 393 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 394 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 395 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 396 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 397 | Supply and delivery of PVC Insulated 3 core flat type copper cable - 6 sq.mm |
| 398 | PVC Insulated 3 core flat type copper cable-10 sq.mm TWAD |
| 399 | Supply and delivery of the following Electrical works:consumable items |
| 400 | Volt meter SR 96 600 V-AC |
| 401 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 402 | LED Outdoor fittings a)30 W LED street light fittings PWD |
| 403 | LED Outdoor fittings a) 48 W LED street light fittings |
| 404 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 405 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 406 | 50mm GI Pipe |
| 407 | 65mm GI Pipe |
| 408 | 80mm GI Pipe |
| 409 | 100mm GI Pipe |
| 410 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 411 | 300mm Sluice Valve |
| 412 | 250mm Sluice Valve |
| 413 | 150mm Sluice Valve |
| 414 | 100mm Sluice Valve |
| 415 | 80mm Sluice Valve |
| 416 | Replacement of non functioning unserviceble Gun Metal Gate valve without affecting existing alignment by using contractor tools excluding the cost of valve but including required length of GI nipple, coupling etc., complete |
| 417 | 100mm GM Valve |
| 418 | 80mm GM Valve |
| 419 | 65mm GM Valve |
| 420 | 50mm GM Valve |
| 421 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 422 | 100mm Air Valve |
| 423 | 80mm Air Valve |
| 424 | 50mm Air Valve |
| 425 | 25mm Air Valve |
| 426 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 427 | 3,00,000 LPH |
| 428 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 429 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 430 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 431 | Sump Cleaning |
| 432 | Charges for cleaning the sumps of TWAD Board by clearing the sludge and disposing it to near by boundary of the sump site including baling out the sludge water by using diesel pumpset of required capacity and removing the algae and scaling by scrapping, flushing the sump finally with bleaching powder and spreading bleaching powder around the sump , etc., complete and as directed by the departmental officers |
| 433 | 6.00 LL capacity of Collection sump @ Keelapalur |
| 434 | 5.00 LL capacity of sump @ Kollapuram |
| 435 | 5.00 LL capacity of sump @ Ogalur |
| 436 | 2.50 LL capacity of sump @ Elumur |
| 437 | 2.50 LL capacity of sump @ Veppur |
| 438 | 1.00 LL capacity of sump @ Sathya Nagar |
| 439 | 1.00 LL capacity of sump @ Poyyur |
| 440 | 1.00 LL capacity of sump @ Nannai |
| 441 | 1.00 LL capacity of sump @ Puduvettakudi |
| 442 | 1.00 LL capacity of sump @ Vayalapadi |
| 443 | 1.50 LL capacity of sump @ Vayalur |
| 444 | 1.50 LL capacity of sump @ Palaiyarasamangalam |
| 445 | 1.50 LL capacity of sump @ Periyavenmani |
| 446 | 1.50 LL capacity of sump @ Kovil Palayam |
| 447 | 1.50 LL capacity of sump @ Melamathur |
| 448 | 1.50 LL capacity of sump @ Raszabath |
| 449 | 1.50 LL capacity of sump @ Kunnam |
| 450 | 1.50 LL capacity of sump @ Lakshmipuram |
| 451 | 1.50 LL capacity of sump @ Murukkankudi |
| 452 | 0.30 LL capacity of sump @ Pudupalayam |
| 453 | 0.30 LL capacity of sump @ Rettipalayam |
| 454 | 0.30 LL capacity of sump @ Malavarayanallur |
| 455 | 0.30 LL capacity of sump @ Z.Athur |
| 456 | 0.30 LL capacity of sump @ Gudalur |
| 457 | 0.30 LL capacity of sump @ Varakupadi |
| 458 | 0.20 LL capacity of sump @ Sathanur |
| 459 | 0.10 LL capacity of sump @ Aranmanaikurichi |
| 460 | 0.10 LL capacity of sump @ Karaipadi |
| 461 | Leak & Burst |
| 462 | Attending Collar Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 463 | 350mm PSC pipe |
| 464 | 500mm PSC pipe |
| 465 | Attending Minor/ Circumfrential Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 466 | 50 mm 6 ksc PVC Pipes |
| 467 | 63mm 4 ksc PVC Pipes |
| 468 | 75mm 4 ksc PVC Pipes |
| 469 | 90mm 4 ksc PVC Pipes |
| 470 | 110mm 4 ksc PVC Pipes |
| 471 | 140mm 4 ksc PVC Pipes |
| 472 | 160mm 4 ksc PVC Pipes |
| 473 | 200mm 4 ksc PVC Pipes |
| 474 | 225mm 4 ksc PVC Pipes |
| 475 | 250mm 4 ksc PVC Pipes |
| 476 | 280mm 4 ksc PVC Pipes |
| 477 | 315mm 4 ksc PVC Pipes |
| 478 | 350mm PSC pipe |
| 479 | 500mm PSC pipe |
| 480 | 500mm DI S/S Pipe |
| 481 | 350mm DI S/S Pipe |
| 482 | 300mm DI S/S Pipe |
| 483 | 250mm DI S/S Pipe |
| 484 | 250mm HDPE PN6 Pipe |
| 485 | 200mm HDPE PN6 Pipe |
| 486 | 160mm HDPE PN6 Pipe |
| 487 | 140mm HDPE PN6 Pipe |
| 488 | 110mm HDPE PN6 Pipe |
| 489 | 90mm HDPE PN6 Pipe |
| 490 | 75mm HDPE PN6 Pipe |
| 491 | 63mm HDPE PN6 Pipe |
| 492 | Attending major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 493 | 50 mm 6 ksc PVC Pipes |
| 494 | 63mm 4 ksc PVC Pipes |
| 495 | 75mm 4 ksc PVC Pipes |
| 496 | 90mm 4 ksc PVC Pipes |
| 497 | 110mm 4 ksc PVC Pipes |
| 498 | 140mm 4 ksc PVC Pipes |
| 499 | 160mm 4 ksc PVC Pipes |
| 500 | 200mm 4 ksc PVC Pipes |
| 501 | 225mm 4 ksc PVC Pipes |
| 502 | 250mm 4 ksc PVC Pipes |
| 503 | 280mm 4 ksc PVC Pipes |
| 504 | 315mm 4 ksc PVC Pipes |
| 505 | 350mm PSC pipe |
| 506 | 500mm PSC pipe |
| 507 | 500mm DI S/S Pipe |
| 508 | 350mm DI S/S Pipe |
| 509 | 300mm DI S/S Pipe |
| 510 | 250mm DI S/S Pipe |
| 511 | 250mm HDPE PN6 Pipe |
| 512 | 200mm HDPE PN6 Pipe |
| 513 | 160mm HDPE PN6 Pipe |
| 514 | 140mm HDPE PN6 Pipe |
| 515 | 110mm HDPE PN6 Pipe |
| 516 | 90mm HDPE PN6 Pipe |
| 517 | 75mm HDPE PN6 Pipe |
| 518 | 63mm HDPE PN6 Pipe |
| 519 | Above GL |
| 520 | 350 mm MS pipe |
| 521 | 500 mm MS pipe |
| 522 | Below GL |
| 523 | 350 mm MS pipe |
| 524 | 500 mm MS pipe |
| 525 | Repairs & Renewals |
| 526 | Attending rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges, taxes within the stipulated time limit etc., complete |
| 527 | Repairing and reconditioning of Motor for 125 HP VT Pumpset including all material,labour,etc |
| 528 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 529 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 530 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 531 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 532 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 533 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 534 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 535 | Transportation charges for conveying the motor from work shop to pumping Station |
| 536 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 537 | Repairing and reconditioning of Pump for 125 HP VT Pumpset including all material,labour,etc |
| 538 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 539 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 540 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 541 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 542 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 543 | Transportation charges for conveying the VT Pump bowl assembly from our work shop to Collector Well Pump room including usage of trolley along the Foot bridge and Van |
| 544 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 545 | Re errection of reconditioned stuffing box, new Head shaft, Discharge head and Motor, fixing the Rachet load bearing assembly including filling of required 90 grade oil and Connecting the 440V AC incoming Cable to the Motor Terminal and fixing new rope in the rope gland and Checking Motor Pumpset Alignment and Rotation and testing with load etc.,Complete |
| 546 | Repairing and reconditioning of Supply of materials for 125 HP VT Pumpset including all material,labour,etc |
| 547 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 548 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 549 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 550 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 551 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 552 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 553 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 554 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 555 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 556 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 557 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 558 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 559 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 560 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 561 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 562 | Attending the repair works in 11 KV/ 433 V Transformer - 315KVA |
| 563 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 564 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 565 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 566 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 567 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 568 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 569 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 570 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 571 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 572 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 573 | Charges for Eart Pit Value Checking with Certificate |
| 574 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 575 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 576 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 577 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 578 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 579 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 580 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 581 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 582 | Supply and delivery of Drop Out fuse fixing unit set |
| 583 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 584 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 585 | Supply and delivery of Silica gel |
| 586 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 587 | Repairing and reconditioning of Motor for 50HP Centrifugal Pumpset |
| 588 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 589 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 590 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 591 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 592 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 593 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 594 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 595 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 596 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 597 | Repairing and reconditioning of Pump for 50HP Centrifugal Pumpset |
| 598 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 599 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 600 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 601 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 602 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 603 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 604 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 605 | Supply and delivery of Driven End and Non Driven End bearings |
| 606 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 607 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 608 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 609 | Repairing and reconditioning of Motor for 25HP Centrifugal Pumpset |
| 610 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 611 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 612 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 613 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 614 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 615 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 616 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 617 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 618 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 619 | Repairing and reconditioning of Pump for 25HP Centrifugal Pumpset |
| 620 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 621 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 622 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 623 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 624 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 625 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 626 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 627 | Supply and delivery of Driven End and Non Driven End bearings |
| 628 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 629 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 630 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 631 | Repairing and reconditioning of Motor & Pump for 30HP Submersible Pumpset |
| 632 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 633 | Transporting the pumpset from Pump House to work shop. |
| 634 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 635 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 636 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 637 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 638 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 639 | Repairing and reconditioning of Motor & Pump for 15HP Submersible Pumpset |
| 640 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 641 | Transporting the pumpset from Pump House to work shop. |
| 642 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 643 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 644 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 645 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 646 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 647 | Repairing and reconditioning of Motor & Pump for 12.5HP Submersible Pumpset |
| 648 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 649 | Transporting the pumpset from Pump House to work shop. |
| 650 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 651 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 652 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 653 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 654 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 655 | Repairing and reconditioning of Motor & Pump for 10HP Submersible Pumpset (Total-12Nos) |
| 656 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 657 | Transporting the pumpset from Pump House to work shop. |
| 658 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 659 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 660 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 661 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 662 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 663 | Repairing and reconditioning of Motor & Pump for 7.5HP Submersible Pumpset - Total 4Nos |
| 664 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 665 | Transporting the pumpset from Pump House to work shop. |
| 666 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 667 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 668 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 669 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 670 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 671 | Repairing and reconditioning of Motor & Pump for 5HP Submersible Pumpset - Total 44 Nos |
| 672 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 673 | Transporting the pumpset from Pump House to work shop. |
| 674 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 675 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 676 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 677 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 678 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 679 | Repairing and reconditioning of Motor & Pump for 4HP & 3HP Submersible Pumpset - Total 6 Nos |
| 680 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 681 | Transporting the pumpset from Pump House to work shop. |
| 682 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 683 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 684 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 685 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 686 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 687 | Repairing and reconditioning of Motor & Pump for 2HP Submersible Pumpset - Total 36 Nos |
| 688 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 689 | Transporting the pumpset from Pump House to work shop. |
| 690 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 691 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 692 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 693 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 694 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 695 | Repairing and reconditioning of Motor & Pump for 1HP Submersible Pumpset - Total 34 Nos |
| 696 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 697 | Transporting the pumpset from Pump House to work shop. |
| 698 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 699 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 700 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 701 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 702 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 703 | Starters |
| 704 | Attending repair works in Soft starter 130 HP |
| 705 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 706 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 707 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 708 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 709 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 710 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 711 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 712 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 713 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 714 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 715 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 716 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 717 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 718 | Attending repair works in ATS starter 60 HP |
| 719 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 720 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 721 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 722 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 723 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 724 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 725 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 726 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 727 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 728 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 729 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 730 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 731 | Attending repair works in ATS starter 30 HP |
| 732 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 733 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 734 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 735 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 736 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 737 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 738 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 739 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 740 | Attending repair works in Star Delta starter 25 HP |
| 741 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 742 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 743 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 744 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 745 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 746 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 747 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 748 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 749 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 750 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 751 | Attending repair works in ATS starter 15 HP |
| 752 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 753 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 754 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 755 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 756 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 757 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 758 | Attending repair works in Star Delta starter 12.5 HP |
| 759 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 760 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 761 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 762 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 763 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 764 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 765 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 766 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 767 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 768 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 769 | Attending repair works in Star Delta starter 10 HP |
| 770 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 771 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 772 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 773 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 774 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 775 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 776 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 777 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 778 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 779 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 780 | Attending repair works in Star Delta starter 7.5 HP |
| 781 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 782 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 783 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 784 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 785 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 786 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 787 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 788 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 789 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 790 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 791 | Attending repair works in DOL starter 5 HP |
| 792 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 793 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 794 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 795 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 796 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 797 | Attending repair works in DOL starter 3 HP |
| 798 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 799 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 800 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 801 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 802 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 803 | Attending repair works in DOL starter 2 HP |
| 804 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 805 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 806 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 807 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 808 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 809 | Attending repair works in DOL starter 1 HP |
| 810 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 811 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 812 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 813 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 814 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 815 | Supply and delivery of PVC Insulated 3 core flat type copper cable - 6 sq.mm |
| 816 | PVC Insulated 3 core flat type copper cable-10 sq.mm TWAD |
| 817 | Supply and delivery of the following Electrical works:consumable items |
| 818 | Volt meter SR 96 600 V-AC |
| 819 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 820 | LED Outdoor fittings a)30 W LED street light fittings |
| 821 | LED Outdoor fittings a) 48 W LED street light fittings |
| 822 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 823 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 824 | 50mm GI Pipe |
| 825 | 65mm GI Pipe |
| 826 | 80mm GI Pipe |
| 827 | 100mm GI Pipe |
| 828 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 829 | 300mm Sluice Valve |
| 830 | 250mm Sluice Valve |
| 831 | 150mm Sluice Valve |
| 832 | 100mm Sluice Valve |
| 833 | 80mm Sluice Valve |
| 834 | Replacement of non functioning unserviceble Gun Metal Gate valve without affecting existing alignment by using contractor tools excluding the cost of valve but including required length of GI nipple, coupling etc., complete |
| 835 | 100mm GM Valve |
| 836 | 80mm GM Valve |
| 837 | 65mm GM Valve |
| 838 | 50mm GM Valve |
| 839 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 840 | 100mm Air Valve |
| 841 | 80mm Air Valve |
| 842 | 50mm Air Valve |
| 843 | 25mm Air Valve |
| 844 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 845 | 3,00,000 LPH |
| 846 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 847 | For the Year 2087-2029(From 01.04.2028 to 31.03.2029) |
| 848 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 849 | Sump Cleaning |
| 850 | Charges for cleaning the sumps of TWAD Board by clearing the sludge and disposing it to near by boundary of the sump site including baling out the sludge water by using diesel pumpset of required capacity and removing the algae and scaling by scrapping, flushing the sump finally with bleaching powder and spreading bleaching powder around the sump , etc., complete and as directed by the departmental officers |
| 851 | 6.00 LL capacity of Collection sump @ Keelapalur |
| 852 | 5.00 LL capacity of sump @ Kollapuram |
| 853 | 5.00 LL capacity of sump @ Ogalur |
| 854 | 2.50 LL capacity of sump @ Elumur |
| 855 | 2.50 LL capacity of sump @ Veppur |
| 856 | 1.00 LL capacity of sump @ Sathya Nagar |
| 857 | 1.00 LL capacity of sump @ Poyyur |
| 858 | 1.00 LL capacity of sump @ Nannai |
| 859 | 1.00 LL capacity of sump @ Puduvettakudi |
| 860 | 1.00 LL capacity of sump @ Vayalapadi |
| 861 | 1.50 LL capacity of sump @ Vayalur |
| 862 | 1.50 LL capacity of sump @ Palaiyarasamangalam |
| 863 | 1.50 LL capacity of sump @ Periyavenmani |
| 864 | 1.50 LL capacity of sump @ Kovil Palayam |
| 865 | 1.50 LL capacity of sump @ Melamathur |
| 866 | 1.50 LL capacity of sump @ Raszabath |
| 867 | 1.50 LL capacity of sump @ Kunnam |
| 868 | 1.50 LL capacity of sump @ Lakshmipuram |
| 869 | 1.50 LL capacity of sump @ Murukkankudi |
| 870 | 0.30 LL capacity of sump @ Pudupalayam |
| 871 | 0.30 LL capacity of sump @ Rettipalayam |
| 872 | 0.30 LL capacity of sump @ Malavarayanallur |
| 873 | 0.30 LL capacity of sump @ Z.Athur |
| 874 | 0.30 LL capacity of sump @ Gudalur |
| 875 | 0.30 LL capacity of sump @ Varakupadi |
| 876 | 0.20 LL capacity of sump @ Sathanur |
| 877 | 0.10 LL capacity of sump @ Aranmanaikurichi |
| 878 | 0.10 LL capacity of sump @ Karaipadi |
| 879 | Leak & Burst |
| 880 | Attending Collar Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 881 | 350mm PSC pipe |
| 882 | 500mm PSC pipe |
| 883 | Attending Minor/ Circumfrential Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 884 | 50 mm 6 ksc PVC Pipes |
| 885 | 63mm 4 ksc PVC Pipes |
| 886 | 75mm 4 ksc PVC Pipes |
| 887 | 90mm 4 ksc PVC Pipes |
| 888 | 110mm 4 ksc PVC Pipes |
| 889 | 140mm 4 ksc PVC Pipes |
| 890 | 160mm 4 ksc PVC Pipes |
| 891 | 200mm 4 ksc PVC Pipes |
| 892 | 225mm 4 ksc PVC Pipes |
| 893 | 250mm 4 ksc PVC Pipes |
| 894 | 280mm 4 ksc PVC Pipes |
| 895 | 315mm 4 ksc PVC Pipes |
| 896 | 350mm PSC pipe |
| 897 | 500mm PSC pipe |
| 898 | 500mm DI S/S Pipe |
| 899 | 350mm DI S/S Pipe |
| 900 | 300mm DI S/S Pipe |
| 901 | 250mm DI S/S Pipe |
| 902 | 250mm HDPE PN6 Pipe |
| 903 | 200mm HDPE PN6 Pipe |
| 904 | 160mm HDPE PN6 Pipe |
| 905 | 140mm HDPE PN6 Pipe |
| 906 | 110mm HDPE PN6 Pipe |
| 907 | 90mm HDPE PN6 Pipe |
| 908 | 75mm HDPE PN6 Pipe |
| 909 | 63mm HDPE PN6 Pipe |
| 910 | Attending major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 911 | 50 mm 6 ksc PVC Pipes |
| 912 | 63mm 4 ksc PVC Pipes |
| 913 | 75mm 4 ksc PVC Pipes |
| 914 | 90mm 4 ksc PVC Pipes |
| 915 | 110mm 4 ksc PVC Pipes |
| 916 | 140mm 4 ksc PVC Pipes |
| 917 | 160mm 4 ksc PVC Pipes |
| 918 | 200mm 4 ksc PVC Pipes |
| 919 | 225mm 4 ksc PVC Pipes |
| 920 | 250mm 4 ksc PVC Pipes |
| 921 | 280mm 4 ksc PVC Pipes |
| 922 | 315mm 4 ksc PVC Pipes |
| 923 | 350mm PSC pipe |
| 924 | 500mm PSC pipe |
| 925 | 500mm DI S/S Pipe |
| 926 | 350mm DI S/S Pipe |
| 927 | 300mm DI S/S Pipe |
| 928 | 250mm DI S/S Pipe |
| 929 | 250mm HDPE PN6 Pipe |
| 930 | 200mm HDPE PN6 Pipe |
| 931 | 160mm HDPE PN6 Pipe |
| 932 | 140mm HDPE PN6 Pipe |
| 933 | 110mm HDPE PN6 Pipe |
| 934 | 90mm HDPE PN6 Pipe |
| 935 | 75mm HDPE PN6 Pipe |
| 936 | 63mm HDPE PN6 Pipe |
| 937 | Above GL |
| 938 | 350 mm MS pipe |
| 939 | 500 mm MS pipe |
| 940 | Below GL |
| 941 | 350 mm MS pipe |
| 942 | 500 mm MS pipe |
| 943 | Repairs & Renewals |
| 944 | Attending rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges, taxes within the stipulated time limit etc., complete |
| 945 | Repairing and reconditioning of Motor for 125 HP VT Pumpset including all material,labour,etc |
| 946 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 947 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 948 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 949 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 950 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 951 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 952 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 953 | Transportation charges for conveying the motor from work shop to pumping Station |
| 954 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 955 | Repairing and reconditioning of Pump for 125 HP VT Pumpset including all material,labour,etc |
| 956 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 957 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 958 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 959 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 960 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 961 | Transportation charges for conveying the VT Pump bowl assembly from our work shop to Collector Well Pump room including usage of trolley along the Foot bridge and Van |
| 962 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 963 | Re errection of reconditioned stuffing box, new Head shaft, Discharge head and Motor, fixing the Rachet load bearing assembly including filling of required 90 grade oil and Connecting the 440V AC incoming Cable to the Motor Terminal and fixing new rope in the rope gland and Checking Motor Pumpset Alignment and Rotation and testing with load etc.,Complete |
| 964 | Repairing and reconditioning of Supply of materials for 125 HP VT Pumpset including all material,labour,etc |
| 965 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 966 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 967 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 968 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 969 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 970 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 971 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 972 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 973 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 974 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 975 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 976 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 977 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 978 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 979 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 980 | Attending the repair works in 11 KV/ 433 V Transformer - 315KVA |
| 981 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 982 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 983 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 984 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 985 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 986 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 987 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 988 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 989 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 990 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 991 | Charges for Eart Pit Value Checking with Certificate |
| 992 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 993 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 994 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 995 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 996 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 997 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 998 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 999 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 1000 | Supply and delivery of Drop Out fuse fixing unit set |
| 1001 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 1002 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 1003 | Supply and delivery of Silica gel |
| 1004 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 1005 | Repairing and reconditioning of Motor for 50HP Centrifugal Pumpset |
| 1006 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1007 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 1008 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1009 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1010 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1011 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1012 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1013 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 1014 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 1015 | Repairing and reconditioning of Pump for 50HP Centrifugal Pumpset |
| 1016 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1017 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 1018 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1019 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1020 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1021 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1022 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1023 | Supply and delivery of Driven End and Non Driven End bearings |
| 1024 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1025 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 1026 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 1027 | Repairing and reconditioning of Motor for 25HP Centrifugal Pumpset |
| 1028 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1029 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 1030 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1031 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1032 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1033 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1034 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1035 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 1036 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 1037 | Repairing and reconditioning of Pump for 25HP Centrifugal Pumpset |
| 1038 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1039 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 1040 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1041 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1042 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1043 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1044 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1045 | Supply and delivery of Driven End and Non Driven End bearings |
| 1046 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1047 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 1048 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 1049 | Repairing and reconditioning of Motor & Pump for 30HP Submersible Pumpset |
| 1050 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1051 | Transporting the pumpset from Pump House to work shop. |
| 1052 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1053 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1054 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1055 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1056 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1057 | Repairing and reconditioning of Motor & Pump for 15HP Submersible Pumpset |
| 1058 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1059 | Transporting the pumpset from Pump House to work shop. |
| 1060 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1061 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1062 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1063 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1064 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1065 | Repairing and reconditioning of Motor & Pump for 12.5HP Submersible Pumpset |
| 1066 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1067 | Transporting the pumpset from Pump House to work shop. |
| 1068 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1069 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1070 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1071 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1072 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1073 | Repairing and reconditioning of Motor & Pump for 10HP Submersible Pumpset (Total-12Nos) |
| 1074 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1075 | Transporting the pumpset from Pump House to work shop. |
| 1076 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1077 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1078 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1079 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1080 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1081 | Repairing and reconditioning of Motor & Pump for 7.5HP Submersible Pumpset - Total 4Nos |
| 1082 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1083 | Transporting the pumpset from Pump House to work shop. |
| 1084 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1085 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1086 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1087 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1088 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1089 | Repairing and reconditioning of Motor & Pump for 5HP Submersible Pumpset - Total 44 Nos |
| 1090 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1091 | Transporting the pumpset from Pump House to work shop. |
| 1092 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1093 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1094 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1095 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1096 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1097 | Repairing and reconditioning of Motor & Pump for 4HP & 3HP Submersible Pumpset - Total 6 Nos |
| 1098 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1099 | Transporting the pumpset from Pump House to work shop. |
| 1100 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1101 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1102 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1103 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1104 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1105 | Repairing and reconditioning of Motor & Pump for 2HP Submersible Pumpset - Total 36 Nos |
| 1106 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1107 | Transporting the pumpset from Pump House to work shop. |
| 1108 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1109 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1110 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1111 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1112 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1113 | Repairing and reconditioning of Motor & Pump for 1HP Submersible Pumpset - Total 34 Nos |
| 1114 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1115 | Transporting the pumpset from Pump House to work shop. |
| 1116 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1117 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1118 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1119 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 1120 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1121 | Starters |
| 1122 | Attending repair works in Soft starter 130 HP |
| 1123 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 1124 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 1125 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 1126 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 1127 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1128 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 1129 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1130 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1131 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1132 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 1133 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 1134 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1135 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1136 | Attending repair works in ATS starter 60 HP |
| 1137 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1138 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 1139 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1140 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1141 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1142 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1143 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1144 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1145 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 1146 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 1147 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1148 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1149 | Attending repair works in ATS starter 30 HP |
| 1150 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1151 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 1152 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1153 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1154 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1155 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1156 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1157 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1158 | Attending repair works in Star Delta starter 25 HP |
| 1159 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1160 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1161 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1162 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1163 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1164 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1165 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1166 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1167 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1168 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1169 | Attending repair works in ATS starter 15 HP |
| 1170 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 1171 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 1172 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1173 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1174 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1175 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1176 | Attending repair works in Star Delta starter 12.5 HP |
| 1177 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1178 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1179 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1180 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1181 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1182 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1183 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1184 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1185 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1186 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1187 | Attending repair works in Star Delta starter 10 HP |
| 1188 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1189 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1190 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1191 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1192 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1193 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1194 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1195 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1196 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1197 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1198 | Attending repair works in Star Delta starter 7.5 HP |
| 1199 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1200 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1201 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1202 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1203 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1204 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1205 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1206 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1207 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1208 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1209 | Attending repair works in DOL starter 5 HP |
| 1210 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1211 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1212 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1213 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1214 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1215 | Attending repair works in DOL starter 3 HP |
| 1216 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1217 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1218 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1219 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1220 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1221 | Attending repair works in DOL starter 2 HP |
| 1222 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1223 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1224 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1225 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1226 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1227 | Attending repair works in DOL starter 1 HP |
| 1228 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1229 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1230 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1231 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1232 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1233 | Supply and delivery of PVC Insulated 3 core flat type copper cable - 6 sq.mm |
| 1234 | PVC Insulated 3 core flat type copper cable-10 sq.mm TWAD |
| 1235 | Supply and delivery of the following Electrical works:consumable items |
| 1236 | Volt meter SR 96 600 V-AC |
| 1237 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 1238 | LED Outdoor fittings a)30 W LED street light fittings |
| 1239 | LED Outdoor fittings a) 48 W LED street light fittings |
| 1240 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 1241 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers |
| 1242 | 50mm GI Pipe |
| 1243 | 65mm GI Pipe |
| 1244 | 80mm GI Pipe |
| 1245 | 100mm GI Pipe |
| 1246 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 1247 | 300mm Sluice Valve |
| 1248 | 250mm Sluice Valve |
| 1249 | 150mm Sluice Valve |
| 1250 | 100mm Sluice Valve |
| 1251 | 80mm Sluice Valve |
| 1252 | Replacement of non functioning unserviceble Gun Metal Gate valve without affecting existing alignment by using contractor tools excluding the cost of valve but including required length of GI nipple, coupling etc., complete |
| 1253 | 100mm GM Valve |
| 1254 | 80mm GM Valve |
| 1255 | 65mm GM Valve |
| 1256 | 50mm GM Valve |
| 1257 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 1258 | 100mm Air Valve |
| 1259 | 80mm Air Valve |
| 1260 | 50mm Air Valve |
| 1261 | 25mm Air Valve |
| 1262 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 1263 | 3,00,000 LPH |
| 1264 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 1265 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 1266 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 1267 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 1268 | Repairing and reconditioning of 15.0 HP Submersible Pumpset including all material,labour,etc at |
| 1269 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1270 | Transporting the pumpset . |
| 1271 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1272 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1273 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1274 | Repairing and reconditioning of 25.0 HP HSC Motor including all material,labour,etc at |
| 1275 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1276 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1277 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1278 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1279 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1280 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1281 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1282 | Repairing and reconditioning of 50 HP HSC Motor including all material,labour,etc at |
| 1283 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1284 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1285 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1286 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1287 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1288 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1289 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1290 | Repairing and reconditioning of 25.00 HP HSC Pump including all material,labour,etc at |
| 1291 | Charges for removing and Reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1292 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 1293 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1294 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1295 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1296 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1297 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1298 | Supply and delivery of Driven End and Non Driven End bearings |
| 1299 | Repairing and reconditioning of 50 HP HSC Pump including all material,labour,etc at |
| 1300 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1301 | Transportation charges for conveying the Pump including loading and unloading charges. |
| 1302 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1303 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1304 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1305 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1306 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1307 | Supply and delivery of Driven End and Non Driven End bearings |
| 1308 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc |
| 1309 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1310 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1311 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1312 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1313 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1314 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1315 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1316 | Repairing and reconditioning of 20 HP HSC Pump including all material,labour,etc |
| 1317 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1318 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 1319 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1320 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1321 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1322 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1323 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1324 | Supply and delivery of Driven End and Non Driven End bearings |
| 1325 | Repairing and reconditioning of 2 HP OW Submersible Pumpset including all material,labour,etc |
| 1326 | Transporting the pumpset . |
| 1327 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1328 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1329 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1330 | Repairing and reconditioning of 3 HP OW Submersible Pumpset including all material,labour,etc |
| 1331 | Transporting the pumpset |
| 1332 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1333 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1334 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1335 | Repairing and reconditioning of 10 HP OW Submersible Pumpset including all material,labour,etc |
| 1336 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1337 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1338 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1339 | Transporting charges for Submersible pumpset |
| 1340 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1341 | Repairing and reconditioning of 1 HP OW Submersible Pumpset including all material,labour,etc |
| 1342 | Transporting the pumpset |
| 1343 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1344 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1345 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1346 | Repairing and reconditioning of 5 HP OW Submersible Pumpset including all material,labour,etc |
| 1347 | Transporting the pumpset |
| 1348 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1349 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1350 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1351 | Repairing and reconditioning of 7.5 HP OW Submersible Pumpset including all material,labour,etc |
| 1352 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1353 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1354 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1355 | Transporting charges for Submersible pumpset |
| 1356 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1357 | Repairing and reconditioning of 20HP OW Submersible Pumpset including all material,labour,etc |
| 1358 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1359 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1360 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1361 | Transporting charges for Submersible pumpset |
| 1362 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1363 | Repairing and reconditioning of 12.5 HP OW Submersible Pumpset Bore Well |
| 1364 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1365 | Transporting the pumpset. |
| 1366 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1367 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1368 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1369 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1370 | Repairing and reconditioning of ATS Starter 15.0 HP |
| 1371 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 1372 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1373 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1374 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1375 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1376 | Repairing and reconditioning of ATS 30.0 HP |
| 1377 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1378 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1379 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1380 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1381 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1382 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1383 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1384 | Repairing and reconditioning of ATS Starter 50 HP |
| 1385 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1386 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1387 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1388 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1389 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1390 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1391 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1392 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 1393 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 1394 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1395 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1396 | Repairing and reconditioning of ATS Starter 20 HP |
| 1397 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1398 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1399 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1400 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1401 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1402 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1403 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1404 | Repairing and reconditioning of ATS Starter 25 HP |
| 1405 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1406 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1407 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1408 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1409 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1410 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1411 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1412 | Repairing and reconditioning of Star-delta Starter 10 HP |
| 1413 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1414 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1415 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1416 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1417 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1418 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1419 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1420 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1421 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1422 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1423 | Repairing and reconditioning of Star-delta Starter 20 HP |
| 1424 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1425 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1426 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1427 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1428 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1429 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1430 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1431 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1432 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1433 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1434 | Repairing and reconditioning of Star-delta Starter 12.5HP |
| 1435 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1436 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1437 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1438 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1439 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1440 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1441 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1442 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1443 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1444 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1445 | Repairing and reconditioning of Star-delta Starter 7.5HP |
| 1446 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1447 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1448 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1449 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1450 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1451 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1452 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1453 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1454 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1455 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1456 | Repairing and reconditioning of DOL Starter 5 HP |
| 1457 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1458 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1459 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1460 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1461 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1462 | Repairing and reconditioning of DOL Starter 3 HP |
| 1463 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1464 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1465 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1466 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1467 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1468 | Repairing and reconditioning of DOL Starter 2 HP |
| 1469 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1470 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1471 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1472 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1473 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1474 | Repairing and reconditioning of DOL Starter 1 HP |
| 1475 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1476 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1477 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1478 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1479 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1480 | Attending cable fault with replacing of cable at Headworks infiltration well to Collection sump |
| 1481 | PVC Insulated 3 core flat type copper cable-10 sq.mm |
| 1482 | Supply and delivery fixing of the following Electrical works:consumable items at the site of work carry out the general maintenance works |
| 1483 | Volt meter SR 96 600 V-AC |
| 1484 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 1485 | LED Outdoor fittings a)30 W LED street light fittings |
| 1486 | Supply and delivery fixing of Moulded case circuit breaker (MCCB) with thermo magneticRelease 100 AMPS 3 Pole |
| 1487 | Supply and delivery fixing of Moulded case circuit breaker (MCCB) with thermo magneticRelease 125 AMPS 3 Pole |
| 1488 | Supply and delivery fixing of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 1489 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 1490 | PVC/HDPE/AC/PSC - Minor Burst |
| 1491 | 50mm 6 ksc PVC Pipes |
| 1492 | 63mm 4 ksc PVC Pipes |
| 1493 | 75mm 4 ksc PVC Pipes |
| 1494 | 90mm 4 ksc PVC Pipes |
| 1495 | 110mm 4 ksc PVC Pipes |
| 1496 | 140mm 4 ksc PVC Pipes |
| 1497 | 160mm 4 ksc PVC Pipes |
| 1498 | 63 HDPE PN 6 Pipe |
| 1499 | 75 HDPE PN 6 Pipe |
| 1500 | 90 HDPE PN 6 Pipe |
| 1501 | 110 HDPE PN 6 Pipe |
| 1502 | 140 HDPE PN 6 Pipe |
| 1503 | 150mm AC pipe |
| 1504 | 200mm AC pipe |
| 1505 | 250mm AC pipe |
| 1506 | 350mm PSC pipe |
| 1507 | 400mm PSC pipe |
| 1508 | GI - Above GL |
| 1509 | 125 GI |
| 1510 | 100 GI |
| 1511 | 80 GI |
| 1512 | 65 GI |
| 1513 | 50 GI |
| 1514 | AC/PSC -Supply of MS Pipe with collar |
| 1515 | 150mm AC pipe |
| 1516 | 200mm AC pipe |
| 1517 | 250mm AC pipe |
| 1518 | 350mm PSC pipe |
| 1519 | 400mm PSC pipe |
| 1520 | PVC/HDPE/AC/PSC - Major Burst |
| 1521 | 50mm 6 ksc PVC Pipes |
| 1522 | 63mm 4 ksc PVC Pipes |
| 1523 | 75mm 4 ksc PVC Pipes |
| 1524 | 90mm 4 ksc PVC Pipes |
| 1525 | 110mm 4 ksc PVC Pipes |
| 1526 | 140mm 4 ksc PVC Pipes |
| 1527 | 160mm 4 ksc PVC Pipes |
| 1528 | 63 HDPE PN 6 Pipe |
| 1529 | 75 HDPE PN 6 Pipe |
| 1530 | 90 HDPE PN 6 Pipe |
| 1531 | 110 HDPE PN 6 Pipe |
| 1532 | 140 HDPE PN 6 Pipe |
| 1533 | 150mm AC pipe |
| 1534 | 200mm AC pipe |
| 1535 | 250mm AC pipe |
| 1536 | 350mm PSC pipe |
| 1537 | 400mm PSC pipe |
| 1538 | MS - Above GL |
| 1539 | 350mm MS |
| 1540 | 400mm MS |
| 1541 | MS - Below GL |
| 1542 | 250mm MS |
| 1543 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 1544 | 100mm CI Sluice Valve |
| 1545 | 150mm CI Sluice Valve |
| 1546 | 50mm DI Single Chamber Air release Valve |
| 1547 | 80mm DI Single Chamber Air release Valve |
| 1548 | 100mm DI Single Chamber Air release Valve |
| 1549 | Replacement of Gun Metal Gate Valve including required length of GI nipple , Coupling etc complete |
| 1550 | 50 mm GM Gate valve |
| 1551 | 80 mm GM Gate valve |
| 1552 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 1553 | 4.00 LL capacity of Collection sump @ Arankottai HW |
| 1554 | 4.00 LL capacity of sump @ Sripuranthan BS |
| 1555 | 2.00 LL capacity of sump @T. Palur BS |
| 1556 | 0.60 LL capacity of sump @ Sathambadi |
| 1557 | 0.60 LL capacity of sump @ Karaikurichy |
| 1558 | 1.00 LL capacity of sump @ Vikkaramangalam BS |
| 1559 | 0.60 LL capacity of sump @ Keelanatham |
| 1560 | 0.30 LL capacity of sump @ Gunamangalam |
| 1561 | 1.00 LL capacity of sump @ Venmankondam |
| 1562 | 0.30 LL capacity of sump @ Uilliyakudi |
| 1563 | 0.10 LL capacity of sump @ Periyar Nagar |
| 1564 | 0.60 LL capacity of sump @ Saveriyarpatty |
| 1565 | 0.30 LL capacity of sump @ Arulmohzli |
| 1566 | 0.30 LL capacity of sump @ Cholamadevi |
| 1567 | 0.30 LL capacity of sump @ Ayeepalayam |
| 1568 | 0.30 LL capacity of sump @ Kodalikaruppur |
| 1569 | 0.30 LL capacity of sump @ Anaikudam |
| 1570 | 0.60LL capacity of sump @ Keela Mickelpatty |
| 1571 | 1.00 LL capacity of sump @ Kandiyankollai |
| 1572 | 0.60 LL capacity of sump @ Sundaresapuram |
| 1573 | 0.60 LL capacity of sump @ Payayankarai |
| 1574 | 1.00 LL capacity of sump @ Kottiyal |
| 1575 | 0.60 LL capacity of sump @ Kasankottai |
| 1576 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 1577 | For the Year 2026-2027 (From 01.04.2027 to 31.03.2028) |
| 1578 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 1579 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 1580 | Repairing and reconditioning of 15.0 HP Submersible Pumpset including all material,labour,etc at |
| 1581 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1582 | Transporting the pumpset . |
| 1583 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1584 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1585 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1586 | Repairing and reconditioning of 25.0 HP HSC Motor including all material,labour,etc at |
| 1587 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1588 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1589 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1590 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1591 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1592 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1593 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1594 | Repairing and reconditioning of 50 HP HSC Motor including all material,labour,etc at |
| 1595 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1596 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1597 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1598 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1599 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1600 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1601 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1602 | Repairing and reconditioning of 25.00 HP HSC Pump including all material,labour,etc at |
| 1603 | Charges for removing and Reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1604 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 1605 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1606 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1607 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1608 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1609 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1610 | Supply and delivery of Driven End and Non Driven End bearings |
| 1611 | Repairing and reconditioning of 50 HP HSC Pump including all material,labour,etc at |
| 1612 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1613 | Transportation charges for conveying the Pump including loading and unloading charges. |
| 1614 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1615 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1616 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1617 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1618 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1619 | Supply and delivery of Driven End and Non Driven End bearings |
| 1620 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc |
| 1621 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1622 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1623 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1624 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1625 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1626 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1627 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1628 | Repairing and reconditioning of 20 HP HSC Pump including all material,labour,etc |
| 1629 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1630 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 1631 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1632 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1633 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1634 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1635 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1636 | Supply and delivery of Driven End and Non Driven End bearings |
| 1637 | Repairing and reconditioning of 2 HP OW Submersible Pumpset including all material,labour,etc |
| 1638 | Transporting the pumpset . |
| 1639 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1640 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1641 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1642 | Repairing and reconditioning of 3 HP OW Submersible Pumpset including all material,labour,etc |
| 1643 | Transporting the pumpset |
| 1644 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1645 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1646 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1647 | Repairing and reconditioning of 10 HP OW Submersible Pumpset including all material,labour,etc |
| 1648 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1649 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1650 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1651 | Transporting charges for Submersible pumpset |
| 1652 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1653 | Repairing and reconditioning of 1 HP OW Submersible Pumpset including all material,labour,etc |
| 1654 | Transporting the pumpset |
| 1655 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1656 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1657 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1658 | Repairing and reconditioning of 5 HP OW Submersible Pumpset including all material,labour,etc |
| 1659 | Transporting the pumpset |
| 1660 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1661 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1662 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1663 | Repairing and reconditioning of 7.5 HP OW Submersible Pumpset including all material,labour,etc |
| 1664 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1665 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1666 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1667 | Transporting charges for Submersible pumpset |
| 1668 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1669 | Repairing and reconditioning of 20HP OW Submersible Pumpset including all material,labour,etc |
| 1670 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1671 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1672 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1673 | Transporting charges for Submersible pumpset |
| 1674 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1675 | Repairing and reconditioning of 12.5 HP OW Submersible Pumpset Bore Well |
| 1676 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1677 | Transporting the pumpset. |
| 1678 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1679 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1680 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1681 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1682 | Repairing and reconditioning of ATS Starter 15.0 HP |
| 1683 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 1684 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1685 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1686 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1687 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1688 | Repairing and reconditioning of ATS 30.0 HP |
| 1689 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1690 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1691 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1692 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1693 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1694 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1695 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1696 | Repairing and reconditioning of ATS Starter 50 HP |
| 1697 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1698 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1699 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1700 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1701 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1702 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1703 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1704 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 1705 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 1706 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1707 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1708 | Repairing and reconditioning of ATS Starter 20 HP |
| 1709 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1710 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1711 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1712 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1713 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1714 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1715 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1716 | Repairing and reconditioning of ATS Starter 25 HP |
| 1717 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 1718 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1719 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1720 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1721 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1722 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1723 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1724 | Repairing and reconditioning of Star-delta Starter 10 HP |
| 1725 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1726 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1727 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1728 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1729 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1730 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1731 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1732 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1733 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1734 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1735 | Repairing and reconditioning of Star-delta Starter 20 HP |
| 1736 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1737 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1738 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1739 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1740 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1741 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1742 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1743 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1744 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1745 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1746 | Repairing and reconditioning of Star-delta Starter 12.5HP |
| 1747 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1748 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1749 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1750 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1751 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1752 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1753 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1754 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1755 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1756 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1757 | Repairing and reconditioning of Star-delta Starter 7.5HP |
| 1758 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 1759 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1760 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 1761 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 1762 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 1763 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1764 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 1765 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 1766 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1767 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1768 | Repairing and reconditioning of DOL Starter 5 HP |
| 1769 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1770 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1771 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1772 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1773 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1774 | Repairing and reconditioning of DOL Starter 3 HP |
| 1775 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1776 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1777 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1778 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1779 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1780 | Repairing and reconditioning of DOL Starter 2 HP |
| 1781 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1782 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1783 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1784 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1785 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1786 | Repairing and reconditioning of DOL Starter 1 HP |
| 1787 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 1788 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 1789 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1790 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 1791 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 1792 | Attending cable fault with replacing of cable at Headworks infiltration well to Collection sump |
| 1793 | PVC Insulated 3 core flat type copper cable-10 sq.mm |
| 1794 | Supply and delivery fixing of the following Electrical works:consumable items at the site of work carry out the general maintenance works |
| 1795 | Volt meter SR 96 600 V-AC |
| 1796 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 1797 | LED Outdoor fittings a)30 W LED street light fittings |
| 1798 | Supply and delivery fixing of Moulded case circuit breaker (MCCB) with thermo magneticRelease 100 AMPS 3 Pole |
| 1799 | Supply and delivery fixing of Moulded case circuit breaker (MCCB) with thermo magneticRelease 125 AMPS 3 Pole |
| 1800 | Supply and delivery fixing of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI markingTWAD SR 2022-23/P.205 |
| 1801 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 1802 | PVC/HDPE/AC/PSC - Minor Burst |
| 1803 | 50mm 6 ksc PVC Pipes |
| 1804 | 63mm 4 ksc PVC Pipes |
| 1805 | 75mm 4 ksc PVC Pipes |
| 1806 | 90mm 4 ksc PVC Pipes |
| 1807 | 110mm 4 ksc PVC Pipes |
| 1808 | 140mm 4 ksc PVC Pipes |
| 1809 | 160mm 4 ksc PVC Pipes |
| 1810 | 63 HDPE PN 6 Pipe |
| 1811 | 75 HDPE PN 6 Pipe |
| 1812 | 90 HDPE PN 6 Pipe |
| 1813 | 110 HDPE PN 6 Pipe |
| 1814 | 140 HDPE PN 6 Pipe |
| 1815 | 150mm AC pipe |
| 1816 | 200mm AC pipe |
| 1817 | 250mm AC pipe |
| 1818 | 350mm PSC pipe |
| 1819 | 400mm PSC pipe |
| 1820 | GI - Above GL |
| 1821 | 125 GI |
| 1822 | 100 GI |
| 1823 | 80 GI |
| 1824 | 65 GI |
| 1825 | 50 GI |
| 1826 | AC/PSC -Supply of MS Pipe with collar |
| 1827 | 150mm AC pipe |
| 1828 | 200mm AC pipe |
| 1829 | 250mm AC pipe |
| 1830 | 350mm PSC pipe |
| 1831 | 400mm PSC pipe |
| 1832 | PVC/HDPE/AC/PSC - Major Burst |
| 1833 | 50mm 6 ksc PVC Pipes |
| 1834 | 63mm 4 ksc PVC Pipes |
| 1835 | 75mm 4 ksc PVC Pipes |
| 1836 | 90mm 4 ksc PVC Pipes |
| 1837 | 110mm 4 ksc PVC Pipes |
| 1838 | 140mm 4 ksc PVC Pipes |
| 1839 | 160mm 4 ksc PVC Pipes |
| 1840 | 63 HDPE PN 6 Pipe |
| 1841 | 75 HDPE PN 6 Pipe |
| 1842 | 90 HDPE PN 6 Pipe |
| 1843 | 110 HDPE PN 6 Pipe |
| 1844 | 140 HDPE PN 6 Pipe |
| 1845 | 150mm AC pipe |
| 1846 | 200mm AC pipe |
| 1847 | 250mm AC pipe |
| 1848 | 350mm PSC pipe |
| 1849 | 400mm PSC pipe |
| 1850 | MS - Above GL |
| 1851 | 350mm MS |
| 1852 | 400mm MS |
| 1853 | MS - Below GL |
| 1854 | 250mm MS |
| 1855 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 1856 | 100mm CI Sluice Valve |
| 1857 | 150mm CI Sluice Valve |
| 1858 | 50mm DI Single Chamber Air release Valve |
| 1859 | 80mm DI Single Chamber Air release Valve |
| 1860 | 100mm DI Single Chamber Air release Valve |
| 1861 | Replacement of Gun Metal Gate Valve including required length of GI nipple , Coupling etc complete |
| 1862 | 50 mm GM Gate valve |
| 1863 | 80 mm GM Gate valve |
| 1864 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 1865 | 4.00 LL capacity of Collection sump @ Arankottai HW |
| 1866 | 4.00 LL capacity of sump @ Sripuranthan BS |
| 1867 | 2.00 LL capacity of sump @T. Palur BS |
| 1868 | 0.60 LL capacity of sump @ Sathambadi |
| 1869 | 0.60 LL capacity of sump @ Karaikurichy |
| 1870 | 1.00 LL capacity of sump @ Vikkaramangalam BS |
| 1871 | 0.60 LL capacity of sump @ Keelanatham |
| 1872 | 0.30 LL capacity of sump @ Gunamangalam |
| 1873 | 1.00 LL capacity of sump @ Venmankondam |
| 1874 | 0.30 LL capacity of sump @ Uilliyakudi |
| 1875 | 0.10 LL capacity of sump @ Periyar Nagar |
| 1876 | 0.60 LL capacity of sump @ Saveriyarpatty |
| 1877 | 0.30 LL capacity of sump @ Arulmohzli |
| 1878 | 0.30 LL capacity of sump @ Cholamadevi |
| 1879 | 0.30 LL capacity of sump @ Ayeepalayam |
| 1880 | 0.30 LL capacity of sump @ Kodalikaruppur |
| 1881 | 0.30 LL capacity of sump @ Anaikudam |
| 1882 | 0.60LL capacity of sump @ Keela Mickelpatty |
| 1883 | 1.00 LL capacity of sump @ Kandiyankollai |
| 1884 | 0.60 LL capacity of sump @ Sundaresapuram |
| 1885 | 0.60 LL capacity of sump @ Payayankarai |
| 1886 | 1.00 LL capacity of sump @ Kottiyal |
| 1887 | 0.60 LL capacity of sump @ Kasankottai |
| 1888 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 1889 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 1890 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 1891 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 1892 | Repairing and reconditioning of 15.0 HP Submersible Pumpset including all material,labour,etc at |
| 1893 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1894 | Transporting the pumpset . |
| 1895 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1896 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1897 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1898 | Repairing and reconditioning of 25.0 HP HSC Motor including all material,labour,etc at |
| 1899 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1900 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1901 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1902 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1903 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1904 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1905 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1906 | Repairing and reconditioning of 50 HP HSC Motor including all material,labour,etc at |
| 1907 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1908 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1909 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1910 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1911 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1912 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1913 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1914 | Repairing and reconditioning of 25.00 HP HSC Pump including all material,labour,etc at |
| 1915 | Charges for removing and Reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1916 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 1917 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1918 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1919 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1920 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1921 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1922 | Supply and delivery of Driven End and Non Driven End bearings |
| 1923 | Repairing and reconditioning of 50 HP HSC Pump including all material,labour,etc at |
| 1924 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1925 | Transportation charges for conveying the Pump including loading and unloading charges. |
| 1926 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1927 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1928 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1929 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1930 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1931 | Supply and delivery of Driven End and Non Driven End bearings |
| 1932 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc |
| 1933 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 1934 | Transportation charges for conveying the motor including loading and unloading charges. |
| 1935 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 1936 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 1937 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 1938 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 1939 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 1940 | Repairing and reconditioning of 20 HP HSC Pump including all material,labour,etc |
| 1941 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 1942 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 1943 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 1944 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 1945 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 1946 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 1947 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 1948 | Supply and delivery of Driven End and Non Driven End bearings |
| 1949 | Repairing and reconditioning of 2 HP OW Submersible Pumpset including all material,labour,etc |
| 1950 | Transporting the pumpset . |
| 1951 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1952 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1953 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1954 | Repairing and reconditioning of 3 HP OW Submersible Pumpset including all material,labour,etc |
| 1955 | Transporting the pumpset |
| 1956 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1957 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1958 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1959 | Repairing and reconditioning of 10 HP OW Submersible Pumpset including all material,labour,etc |
| 1960 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1961 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1962 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1963 | Transporting charges for Submersible pumpset |
| 1964 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1965 | Repairing and reconditioning of 1 HP OW Submersible Pumpset including all material,labour,etc |
| 1966 | Transporting the pumpset |
| 1967 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1968 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1969 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1970 | Repairing and reconditioning of 5 HP OW Submersible Pumpset including all material,labour,etc |
| 1971 | Transporting the pumpset |
| 1972 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1973 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1974 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1975 | Repairing and reconditioning of 7.5 HP OW Submersible Pumpset including all material,labour,etc |
| 1976 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1977 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1978 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1979 | Transporting charges for Submersible pumpset |
| 1980 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1981 | Repairing and reconditioning of 20HP OW Submersible Pumpset including all material,labour,etc |
| 1982 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1983 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1984 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1985 | Transporting charges for Submersible pumpset |
| 1986 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1987 | Repairing and reconditioning of 12.5 HP OW Submersible Pumpset Bore Well |
| 1988 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 1989 | Transporting the pumpset. |
| 1990 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 1991 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 1992 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 1993 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 1994 | Repairing and reconditioning of ATS Starter 15.0 HP |
| 1995 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 1996 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 1997 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 1998 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 1999 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2000 | Repairing and reconditioning of ATS 30.0 HP |
| 2001 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2002 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2003 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2004 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2005 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2006 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2007 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2008 | Repairing and reconditioning of ATS Starter 50 HP |
| 2009 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2010 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2011 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2012 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2013 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2014 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2015 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2016 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 2017 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 2018 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2019 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2020 | Repairing and reconditioning of ATS Starter 20 HP |
| 2021 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2022 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2023 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2024 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2025 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2026 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2027 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2028 | Repairing and reconditioning of ATS Starter 25 HP |
| 2029 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2030 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2031 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2032 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2033 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2034 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2035 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2036 | Repairing and reconditioning of Star-delta Starter 10 HP |
| 2037 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2038 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2039 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2040 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2041 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2042 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2043 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2044 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2045 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2046 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2047 | Repairing and reconditioning of Star-delta Starter 20 HP |
| 2048 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2049 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2050 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2051 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2052 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2053 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2054 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2055 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2056 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2057 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2058 | Repairing and reconditioning of Star-delta Starter 12.5HP |
| 2059 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2060 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2061 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2062 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2063 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2064 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2065 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2066 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2067 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2068 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2069 | Repairing and reconditioning of Star-delta Starter 7.5HP |
| 2070 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2071 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2072 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2073 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2074 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2075 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2076 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2077 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2078 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2079 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2080 | Repairing and reconditioning of DOL Starter 5 HP |
| 2081 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2082 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2083 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2084 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2085 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2086 | Repairing and reconditioning of DOL Starter 3 HP |
| 2087 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2088 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2089 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2090 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2091 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2092 | Repairing and reconditioning of DOL Starter 2 HP |
| 2093 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2094 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2095 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2096 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2097 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2098 | Repairing and reconditioning of DOL Starter 1 HP |
| 2099 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2100 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2101 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2102 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2103 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2104 | Attending cable fault with replacing of cable at Headworks infiltration well to Collection sump |
| 2105 | PVC Insulated 3 core flat type copper cable-10 sq.mm |
| 2106 | Supply and delivery fixing of the following Electrical works:consumable items at the site of work carry out the general maintenance works |
| 2107 | Volt meter SR 96 600 V-AC |
| 2108 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2109 | LED Outdoor fittings a)30 W LED street light fittings |
| 2110 | Supply and delivery fixing of Moulded case circuit breaker (MCCB) with thermo magneticRelease 100 AMPS 3 Pole |
| 2111 | Supply and delivery fixing of Moulded case circuit breaker (MCCB) with thermo magneticRelease 125 AMPS 3 Pole |
| 2112 | Supply and delivery fixing of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2113 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2114 | PVC/HDPE/AC/PSC - Minor Burst |
| 2115 | 50mm 6 ksc PVC Pipes |
| 2116 | 63mm 4 ksc PVC Pipes |
| 2117 | 75mm 4 ksc PVC Pipes |
| 2118 | 90mm 4 ksc PVC Pipes |
| 2119 | 110mm 4 ksc PVC Pipes |
| 2120 | 140mm 4 ksc PVC Pipes |
| 2121 | 160mm 4 ksc PVC Pipes |
| 2122 | 63 HDPE PN 6 Pipe |
| 2123 | 75 HDPE PN 6 Pipe |
| 2124 | 90 HDPE PN 6 Pipe |
| 2125 | 110 HDPE PN 6 Pipe |
| 2126 | 140 HDPE PN 6 Pipe |
| 2127 | 150mm AC pipe |
| 2128 | 200mm AC pipe |
| 2129 | 250mm AC pipe |
| 2130 | 350mm PSC pipe |
| 2131 | 400mm PSC pipe |
| 2132 | GI - Above GL |
| 2133 | 125 GI |
| 2134 | 100 GI |
| 2135 | 80 GI |
| 2136 | 65 GI |
| 2137 | 50 GI |
| 2138 | AC/PSC -Supply of MS Pipe with collar |
| 2139 | 150mm AC pipe |
| 2140 | 200mm AC pipe |
| 2141 | 250mm AC pipe |
| 2142 | 350mm PSC pipe |
| 2143 | 400mm PSC pipe |
| 2144 | PVC/HDPE/AC/PSC - Major Burst |
| 2145 | 50mm 6 ksc PVC Pipes |
| 2146 | 63mm 4 ksc PVC Pipes |
| 2147 | 75mm 4 ksc PVC Pipes |
| 2148 | 90mm 4 ksc PVC Pipes |
| 2149 | 110mm 4 ksc PVC Pipes |
| 2150 | 140mm 4 ksc PVC Pipes |
| 2151 | 160mm 4 ksc PVC Pipes |
| 2152 | 63 HDPE PN 6 Pipe |
| 2153 | 75 HDPE PN 6 Pipe |
| 2154 | 90 HDPE PN 6 Pipe |
| 2155 | 110 HDPE PN 6 Pipe |
| 2156 | 140 HDPE PN 6 Pipe |
| 2157 | 150mm AC pipe |
| 2158 | 200mm AC pipe |
| 2159 | 250mm AC pipe |
| 2160 | 350mm PSC pipe |
| 2161 | 400mm PSC pipe |
| 2162 | MS - Above GL |
| 2163 | 350mm MS |
| 2164 | 400mm MS |
| 2165 | MS - Below GL |
| 2166 | 250mm MS |
| 2167 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 2168 | 100mm CI Sluice Valve |
| 2169 | 150mm CI Sluice Valve |
| 2170 | 50mm DI Single Chamber Air release Valve |
| 2171 | 80mm DI Single Chamber Air release Valve |
| 2172 | 100mm DI Single Chamber Air release Valve |
| 2173 | Replacement of Gun Metal Gate Valve including required length of GI nipple , Coupling etc complete |
| 2174 | 50 mm GM Gate valve |
| 2175 | 80 mm GM Gate valve |
| 2176 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2177 | 4.00 LL capacity of Collection sump @ Arankottai HW |
| 2178 | 4.00 LL capacity of sump @ Sripuranthan BS |
| 2179 | 2.00 LL capacity of sump @T. Palur BS |
| 2180 | 0.60 LL capacity of sump @ Sathambadi |
| 2181 | 0.60 LL capacity of sump @ Karaikurichy |
| 2182 | 1.00 LL capacity of sump @ Vikkaramangalam BS |
| 2183 | 0.60 LL capacity of sump @ Keelanatham |
| 2184 | 0.30 LL capacity of sump @ Gunamangalam |
| 2185 | 1.00 LL capacity of sump @ Venmankondam |
| 2186 | 0.30 LL capacity of sump @ Uilliyakudi |
| 2187 | 0.10 LL capacity of sump @ Periyar Nagar |
| 2188 | 0.60 LL capacity of sump @ Saveriyarpatty |
| 2189 | 0.30 LL capacity of sump @ Arulmohzli |
| 2190 | 0.30 LL capacity of sump @ Cholamadevi |
| 2191 | 0.30 LL capacity of sump @ Ayeepalayam |
| 2192 | 0.30 LL capacity of sump @ Kodalikaruppur |
| 2193 | 0.30 LL capacity of sump @ Anaikudam |
| 2194 | 0.60LL capacity of sump @ Keela Mickelpatty |
| 2195 | 1.00 LL capacity of sump @ Kandiyankollai |
| 2196 | 0.60 LL capacity of sump @ Sundaresapuram |
| 2197 | 0.60 LL capacity of sump @ Payayankarai |
| 2198 | 1.00 LL capacity of sump @ Kottiyal |
| 2199 | 0.60 LL capacity of sump @ Kasankottai |
| 2200 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 2201 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 2202 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2203 | Sump Cleaning |
| 2204 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries, materials, labour, all incidental chargs, application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2205 | 40000 Lt capacity of sundakudi sump |
| 2206 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2207 | 150mm AC CL 15 Pipes |
| 2208 | 200mm AC CL 15 Pipes |
| 2209 | 250mm AC CL 15 Pipes |
| 2210 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2211 | 50 mm 6 ksc PVC Pipes |
| 2212 | 63mm 4 ksc PVC Pipes |
| 2213 | 75mm 4 ksc PVC Pipes |
| 2214 | 90 mm 4 ksc PVC Pipes |
| 2215 | 140mm 4 ksc PVC Pipes |
| 2216 | 225mm 4 KSC PVC Pipes |
| 2217 | 150mm AC CL 15 Pipes |
| 2218 | 200mm AC CL 15 Pipes |
| 2219 | 250mm AC CL 15 Pipes |
| 2220 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2221 | 50 mm 6 ksc PVC Pipes |
| 2222 | 63mm 4 ksc PVC Pipes |
| 2223 | 75mm 4 ksc PVC Pipes |
| 2224 | 90 mm 4 ksc PVC Pipes |
| 2225 | 140mm 4 ksc PVC Pipes |
| 2226 | 225mm 4 KSC PVC Pipes |
| 2227 | 150mm AC CL 15 Pipes |
| 2228 | 200mm AC CL 15 Pipes |
| 2229 | 250mm AC CL 15 Pipes |
| 2230 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2231 | Repairing and reconditioning of Pump for 30 HP Submersible Pumpset |
| 2232 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2233 | Transporting the pumpset from Pump House to work shop. |
| 2234 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2235 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2236 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2237 | Repairing and reconditioning of Pump for 7.50 HP Centrifugal Pumpset-Sump at sundakudi 1 No |
| 2238 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 2239 | Transporting the pumpset. |
| 2240 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 2241 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 2242 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2243 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 2244 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 2245 | Repairing and reconditioning of Pump for 12.50 HP Submersible Pumpset bore well |
| 2246 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2247 | Transporting the pumpset. |
| 2248 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2249 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2250 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2251 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2252 | Repairing of Starter ATS 30 HP |
| 2253 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2254 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2255 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2256 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2257 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2258 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2259 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2260 | Repairing of Starter Star & Delta 12.5 HP |
| 2261 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2262 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2263 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2264 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2265 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2266 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2267 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2268 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2269 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2270 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2271 | Repairing of Starter Star & Delta 7.50 HP |
| 2272 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2273 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2274 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2275 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2276 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2277 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2278 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2279 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2280 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2281 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2282 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2283 | Supply and delivery of the following Electrical works:consumable items |
| 2284 | Volt meter SR 96 600 V-AC |
| 2285 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2286 | LED Outdoor fittings a)30 W LED street light fittings |
| 2287 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2288 | Supply and delivery of DI Single Chamber Air release ValveTWAD |
| 2289 | DI Single Chamber Air release Valve 80mm for 250mm Pipe |
| 2290 | DI Single Chamber Air release Valve 50mm for 200mm Pipe |
| 2291 | Single Air CI valve 25mm |
| 2292 | Supply of Flow control valve 40mm (1LPM to 400 LPM adjustable type arragements) |
| 2293 | Flow control Valve |
| 2294 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 2295 | 150mm Sluice Valve |
| 2296 | Supply and delivery of GM gate valve and as per IS BS5154 |
| 2297 | 50mm GM Valve |
| 2298 | Repair and Reconditioning of the Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 2299 | Repairing 80mm Air Valve |
| 2300 | Repairing 50mm Air Valve |
| 2301 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 2302 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 2303 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2304 | Sump Cleaning |
| 2305 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries, materials, labour, all incidental chargs, application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2306 | 40000 Lt capacity of sundakudi sump |
| 2307 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2308 | 150mm AC CL 15 Pipes |
| 2309 | 200mm AC CL 15 Pipes |
| 2310 | 250mm AC CL 15 Pipes |
| 2311 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2312 | 50 mm 6 ksc PVC Pipes |
| 2313 | 63mm 4 ksc PVC Pipes |
| 2314 | 75mm 4 ksc PVC Pipes |
| 2315 | 90 mm 4 ksc PVC Pipes |
| 2316 | 140mm 4 ksc PVC Pipes |
| 2317 | 225mm 4 KSC PVC Pipes |
| 2318 | 150mm AC CL 15 Pipes |
| 2319 | 200mm AC CL 15 Pipes |
| 2320 | 250mm AC CL 15 Pipes |
| 2321 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2322 | 50 mm 6 ksc PVC Pipes |
| 2323 | 63mm 4 ksc PVC Pipes |
| 2324 | 75mm 4 ksc PVC Pipes |
| 2325 | 90 mm 4 ksc PVC Pipes |
| 2326 | 140mm 4 ksc PVC Pipes |
| 2327 | 225mm 4 KSC PVC Pipes |
| 2328 | 150mm AC CL 15 Pipes |
| 2329 | 200mm AC CL 15 Pipes |
| 2330 | 250mm AC CL 15 Pipes |
| 2331 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2332 | Repairing and reconditioning of Pump for 30 HP Submersible Pumpset |
| 2333 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2334 | Transporting the pumpset from Pump House to work shop. |
| 2335 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2336 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2337 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2338 | Repairing and reconditioning of Pump for 7.50 HP Centrifugal Pumpset-Sump at sundakudi 1 No |
| 2339 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 2340 | Transporting the pumpset. |
| 2341 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 2342 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 2343 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2344 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 2345 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 2346 | Repairing and reconditioning of Pump for 12.50 HP Submersible Pumpset bore well |
| 2347 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2348 | Transporting the pumpset. |
| 2349 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2350 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2351 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2352 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2353 | Repairing of Starter ATS 30 HP |
| 2354 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2355 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2356 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2357 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2358 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2359 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2360 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2361 | Repairing of Starter Star & Delta 12.5 HP |
| 2362 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2363 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2364 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2365 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2366 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2367 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2368 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2369 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2370 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2371 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2372 | Repairing of Starter Star & Delta 7.50 HP |
| 2373 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2374 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2375 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2376 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2377 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2378 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2379 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2380 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2381 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2382 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2383 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2384 | Supply and delivery of the following Electrical works:consumable items |
| 2385 | Volt meter SR 96 600 V-AC |
| 2386 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2387 | LED Outdoor fittings a)30 W LED street light fittings PWD |
| 2388 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2389 | Supply and delivery of DI Single Chamber Air release Valve |
| 2390 | DI Single Chamber Air release Valve 80mm for 250mm Pipe |
| 2391 | DI Single Chamber Air release Valve 50mm for 200mm Pipe |
| 2392 | Single Air CI valve 25mm |
| 2393 | Supply of Flow control valve 40mm (1LPM to 400 LPM adjustable type arragements) |
| 2394 | Flow control Valve |
| 2395 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 2396 | 150mm Sluice Valve |
| 2397 | Supply and delivery of GM gate valve and as per IS BS5154 |
| 2398 | 50mm GM Valve |
| 2399 | Repair and Reconditioning of the Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 2400 | Repairing 80mm Air Valve |
| 2401 | Repairing 50mm Air Valve |
| 2402 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 2403 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 2404 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2405 | Sump Cleaning |
| 2406 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries, materials, labour, all incidental chargs, application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2407 | 40000 Lt capacity of sundakudi sump |
| 2408 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2409 | 150mm AC CL 15 Pipes |
| 2410 | 200mm AC CL 15 Pipes |
| 2411 | 250mm AC CL 15 Pipes |
| 2412 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2413 | 50 mm 6 ksc PVC Pipes |
| 2414 | 63mm 4 ksc PVC Pipes |
| 2415 | 75mm 4 ksc PVC Pipes |
| 2416 | 90 mm 4 ksc PVC Pipes |
| 2417 | 140mm 4 ksc PVC Pipes |
| 2418 | 225mm 4 KSC PVC Pipes |
| 2419 | 150mm AC CL 15 Pipes |
| 2420 | 200mm AC CL 15 Pipes |
| 2421 | 250mm AC CL 15 Pipes |
| 2422 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2423 | 50 mm 6 ksc PVC Pipes |
| 2424 | 63mm 4 ksc PVC Pipes |
| 2425 | 75mm 4 ksc PVC Pipes |
| 2426 | 90 mm 4 ksc PVC Pipes |
| 2427 | 140mm 4 ksc PVC Pipes |
| 2428 | 225mm 4 KSC PVC Pipes |
| 2429 | 150mm AC CL 15 Pipes |
| 2430 | 200mm AC CL 15 Pipes |
| 2431 | 250mm AC CL 15 Pipes |
| 2432 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2433 | Repairing and reconditioning of Pump for 30 HP Submersible Pumpset |
| 2434 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2435 | Transporting the pumpset from Pump House to work shop. |
| 2436 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2437 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2438 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2439 | Repairing and reconditioning of Pump for 7.50 HP Centrifugal Pumpset-Sump at sundakudi 1 No |
| 2440 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 2441 | Transporting the pumpset. |
| 2442 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 2443 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 2444 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2445 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 2446 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 2447 | Repairing and reconditioning of Pump for 12.50 HP Submersible Pumpset bore well |
| 2448 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2449 | Transporting the pumpset. |
| 2450 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2451 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2452 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2453 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2454 | Repairing of Starter ATS 30 HP |
| 2455 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2456 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2457 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2458 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2459 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2460 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2461 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2462 | Repairing of Starter Star & Delta 12.5 HP |
| 2463 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2464 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2465 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2466 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2467 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2468 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2469 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2470 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2471 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2472 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2473 | Repairing of Starter Star & Delta 7.50 HP |
| 2474 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2475 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2476 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2477 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2478 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2479 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2480 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2481 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2482 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2483 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2484 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2485 | Supply and delivery of the following Electrical works:consumable items |
| 2486 | Volt meter SR 96 600 V-AC |
| 2487 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2488 | LED Outdoor fittings a)30 W LED street light fittings |
| 2489 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2490 | Supply and delivery of DI Single Chamber Air release Valve |
| 2491 | DI Single Chamber Air release Valve 80mm for 250mm Pipe |
| 2492 | DI Single Chamber Air release Valve 50mm for 200mm Pipe |
| 2493 | Single Air CI valve 25mm |
| 2494 | Supply of Flow control valve 40mm (1LPM to 400 LPM adjustable type arragements) |
| 2495 | Flow control Valve |
| 2496 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 2497 | 150mm Sluice Valve |
| 2498 | Supply and delivery of GM gate valve and as per IS BS5154 |
| 2499 | 50mm GM Valve |
| 2500 | Repair and Reconditioning of the Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 2501 | Repairing 80mm Air Valve |
| 2502 | Repairing 50mm Air Valve |
| 2503 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 2504 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 2505 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2506 | Leak and Burst works |
| 2507 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2508 | 200mm AC CL 15 Pipes |
| 2509 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2510 | 50 mm 6 ksc PVC Pipes |
| 2511 | 63mm 4 ksc PVC Pipes |
| 2512 | 75mm 4 ksc PVC Pipes |
| 2513 | 90mm 4 ksc PVC Pipes |
| 2514 | 110mm 4Ksc PVC Pipes |
| 2515 | 140mm 4 ksc PVC Pipes |
| 2516 | 200mm AC CL 15 Pipes |
| 2517 | 63mm HDPE PN6 |
| 2518 | 75mm HDPE PN6 |
| 2519 | 90mm HDPE PN6 |
| 2520 | 110mm HDPE PN6 |
| 2521 | 140mm HDPE PN6 |
| 2522 | 200mm HDPE PN6 |
| 2523 | 200mm HDPE PN8 |
| 2524 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2525 | 50 mm 6 ksc PVC Pipes |
| 2526 | 63mm 4 ksc PVC Pipes |
| 2527 | 75mm 4 ksc PVC Pipes |
| 2528 | 90mm 4 ksc PVC Pipes |
| 2529 | 110mm 4Ksc PVC Pipes |
| 2530 | 140mm 4 ksc PVC Pipes |
| 2531 | 200mm AC CL 15 Pipes |
| 2532 | 63mm HDPE PN6 |
| 2533 | 75mm HDPE PN6 |
| 2534 | 90mm HDPE PN6 |
| 2535 | 110mm HDPE PN6 |
| 2536 | 140mm HDPE PN6 |
| 2537 | 200mm HDPE PN6 |
| 2538 | 200mm HDPE PN8 |
| 2539 | Attending in the GI pipe leak above GL of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II. |
| 2540 | 50mm GI Pipe |
| 2541 | 65mm GI Pipe |
| 2542 | 80mm GI Pipe |
| 2543 | 100mm GI Pipe |
| 2544 | Repairs & Renewals |
| 2545 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2546 | Repairing and reconditioning of Pump for 30 HP Submersible Pumpset including all material,labour,etc |
| 2547 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2548 | Transporting the pumpset from Pump House to work shop. |
| 2549 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2550 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2551 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2552 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 2553 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2554 | Repairing and reconditioning of Pump for12.50 HP Submersible Pumpset 1No |
| 2555 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2556 | Transporting the pumpset from Pump House to work shop. |
| 2557 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2558 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2559 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2560 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 2561 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2562 | Repairing and reconditioning of Pump for 1 HP Monoblock Pumpset-SP at Kovilur -1 No |
| 2563 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 2564 | Transporting the pumpset from the Pumping Station to work shop. |
| 2565 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 2566 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 2567 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2568 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 2569 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 2570 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 2571 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 2572 | Repair of Starter ATS 30 HP |
| 2573 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2574 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 2575 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2576 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2577 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2578 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2579 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2580 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2581 | Repair of Starter Star Delta 12.5 HP |
| 2582 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2583 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2584 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2585 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2586 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2587 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2588 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2589 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2590 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2591 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2592 | Repair of Starter DOL 1 HP |
| 2593 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2594 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2595 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2596 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2597 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2598 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2599 | Supply and delivery of the following Electrical works:consumable items |
| 2600 | Volt meter SR 96 600 V-AC |
| 2601 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2602 | LED Outdoor fittings a)30 W LED street light fittings |
| 2603 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2604 | Sump Cleaning |
| 2605 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2606 | 1.00 LL capacity of Kovilur stand post |
| 2607 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 2608 | 50,000 LPH |
| 2609 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 2610 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2611 | Leak and Burst works |
| 2612 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2613 | 200mm AC CL 15 Pipes |
| 2614 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2615 | 50 mm 6 ksc PVC Pipes |
| 2616 | 63mm 4 ksc PVC Pipes |
| 2617 | 75mm 4 ksc PVC Pipes |
| 2618 | 90mm 4 ksc PVC Pipes |
| 2619 | 110mm 4Ksc PVC Pipes |
| 2620 | 140mm 4 ksc PVC Pipes |
| 2621 | 200mm AC CL 15 Pipes |
| 2622 | 63mm HDPE PN6 |
| 2623 | 75mm HDPE PN6 |
| 2624 | 90mm HDPE PN6 |
| 2625 | 110mm HDPE PN6 |
| 2626 | 140mm HDPE PN6 |
| 2627 | 200mm HDPE PN6 |
| 2628 | 200mm HDPE PN8 |
| 2629 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2630 | 50 mm 6 ksc PVC Pipes |
| 2631 | 63mm 4 ksc PVC Pipes |
| 2632 | 75mm 4 ksc PVC Pipes |
| 2633 | 90mm 4 ksc PVC Pipes |
| 2634 | 110mm 4Ksc PVC Pipes |
| 2635 | 140mm 4 ksc PVC Pipes |
| 2636 | 200mm AC CL 15 Pipes |
| 2637 | 63mm HDPE PN6 |
| 2638 | 75mm HDPE PN6 |
| 2639 | 90mm HDPE PN6 |
| 2640 | 110mm HDPE PN6 |
| 2641 | 140mm HDPE PN6 |
| 2642 | 200mm HDPE PN6 |
| 2643 | 200mm HDPE PN8 |
| 2644 | Attending in the GI pipe leak above GL of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II. |
| 2645 | 50mm GI Pipe |
| 2646 | 65mm GI Pipe |
| 2647 | 80mm GI Pipe |
| 2648 | 100mm GI Pipe |
| 2649 | Repairs & Renewals |
| 2650 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2651 | Repairing and reconditioning of Pump for 30 HP Submersible Pumpset including all material,labour,etc |
| 2652 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2653 | Transporting the pumpset from Pump House to work shop. |
| 2654 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2655 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2656 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2657 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 2658 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2659 | Repairing and reconditioning of Pump for12.50 HP Submersible Pumpset 1No |
| 2660 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2661 | Transporting the pumpset from Pump House to work shop. |
| 2662 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2663 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2664 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2665 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 2666 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2667 | Repairing and reconditioning of Pump for 1 HP Monoblock Pumpset-SP at Kovilur -1 No |
| 2668 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 2669 | Transporting the pumpset from the Pumping Station to work shop. |
| 2670 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 2671 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 2672 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2673 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 2674 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 2675 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 2676 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 2677 | Repair of Starter ATS 30 HP |
| 2678 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2679 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 2680 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2681 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2682 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2683 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2684 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2685 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2686 | Repair of Starter Star Delta 12.5 HP |
| 2687 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2688 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2689 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2690 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2691 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2692 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2693 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2694 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2695 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2696 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2697 | Repair of Starter DOL 1 HP |
| 2698 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2699 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2700 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2701 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2702 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2703 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2704 | Supply and delivery of the following Electrical works:consumable items |
| 2705 | Volt meter SR 96 600 V-AC |
| 2706 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2707 | LED Outdoor fittings a)30 W LED street light fittings |
| 2708 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2709 | Sump Cleaning |
| 2710 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2711 | 1.00 LL capacity of Kovilur stand post |
| 2712 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 2713 | 50,000 LPH |
| 2714 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 2715 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2716 | Leak and Burst works |
| 2717 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2718 | 200mm AC CL 15 Pipes |
| 2719 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2720 | 50 mm 6 ksc PVC Pipes |
| 2721 | 63mm 4 ksc PVC Pipes |
| 2722 | 75mm 4 ksc PVC Pipes |
| 2723 | 90mm 4 ksc PVC Pipes |
| 2724 | 110mm 4Ksc PVC Pipes |
| 2725 | 140mm 4 ksc PVC Pipes |
| 2726 | 200mm AC CL 15 Pipes |
| 2727 | 63mm HDPE PN6 |
| 2728 | 75mm HDPE PN6 |
| 2729 | 90mm HDPE PN6 |
| 2730 | 110mm HDPE PN6 |
| 2731 | 140mm HDPE PN6 |
| 2732 | 200mm HDPE PN6 |
| 2733 | 200mm HDPE PN8 |
| 2734 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2735 | 50 mm 6 ksc PVC Pipes |
| 2736 | 63mm 4 ksc PVC Pipes |
| 2737 | 75mm 4 ksc PVC Pipes |
| 2738 | 90mm 4 ksc PVC Pipes |
| 2739 | 110mm 4Ksc PVC Pipes |
| 2740 | 140mm 4 ksc PVC Pipes |
| 2741 | 200mm AC CL 15 Pipes |
| 2742 | 63mm HDPE PN6 |
| 2743 | 75mm HDPE PN6 |
| 2744 | 90mm HDPE PN6 |
| 2745 | 110mm HDPE PN6 |
| 2746 | 140mm HDPE PN6 |
| 2747 | 200mm HDPE PN6 |
| 2748 | 200mm HDPE PN8 |
| 2749 | Attending in the GI pipe leak above GL of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II. |
| 2750 | 50mm GI Pipe |
| 2751 | 65mm GI Pipe |
| 2752 | 80mm GI Pipe |
| 2753 | 100mm GI Pipe |
| 2754 | Repairs & Renewals |
| 2755 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2756 | Repairing and reconditioning of Pump for 30 HP Submersible Pumpset including all material,labour,etc |
| 2757 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2758 | Transporting the pumpset from Pump House to work shop. |
| 2759 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2760 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2761 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2762 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 2763 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2764 | Repairing and reconditioning of Pump for12.50 HP Submersible Pumpset 1No |
| 2765 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2766 | Transporting the pumpset from Pump House to work shop. |
| 2767 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2768 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2769 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2770 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 2771 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2772 | Repairing and reconditioning of Pump for 1 HP Monoblock Pumpset-SP at Kovilur -1 No |
| 2773 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 2774 | Transporting the pumpset from the Pumping Station to work shop. |
| 2775 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 2776 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 2777 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2778 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 2779 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 2780 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 2781 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 2782 | Repair of Starter ATS 30 HP |
| 2783 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2784 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 2785 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2786 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2787 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2788 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2789 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2790 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2791 | Repair of Starter Star Delta 12.5 HP |
| 2792 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2793 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2794 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2795 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2796 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2797 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2798 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2799 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2800 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2801 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2802 | Repair of Starter DOL 1 HP |
| 2803 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 2804 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2805 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2806 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2807 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2808 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2809 | Supply and delivery of the following Electrical works:consumable items |
| 2810 | Volt meter SR 96 600 V-AC |
| 2811 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2812 | LED Outdoor fittings a)30 W LED street light fittings |
| 2813 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2814 | Sump Cleaning |
| 2815 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2816 | 1.00 LL capacity of Kovilur stand post |
| 2817 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 2818 | 50,000 LPH |
| 2819 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 2820 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2821 | Leak and Burst works |
| 2822 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2823 | 300mm AC CL15 pipe |
| 2824 | 350mm PSC pipe |
| 2825 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2826 | 300mm AC CL 15 pipe |
| 2827 | 350mm PSC pipe |
| 2828 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2829 | 150mm CI Pipe |
| 2830 | 300mm AC CL 15 Pipe |
| 2831 | 350mm PSC pipe |
| 2832 | Repairs & Renewals |
| 2833 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2834 | Repairing and reconditioning of 40 HP HSC Motor including all material,labour,etc at Kodalikaruppur HW |
| 2835 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 2836 | Transportation charges for conveying the motor including loading and unloading charges. |
| 2837 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 2838 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 2839 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 2840 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 2841 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2842 | Repairing and reconditioning of 40 HP HSC Pump including all material,labour,etc at Kodalikaruppur HW |
| 2843 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 2844 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 2845 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 2846 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 2847 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 2848 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 2849 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 2850 | Supply and delivery of Driven End and Non Driven End bearings |
| 2851 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2852 | Repairing and reconditioning of 60 HP HSC Motor including all material,labour,etc at Anaikudam BS |
| 2853 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 2854 | Transportation charges for conveying the motor including loading and unloading charges. |
| 2855 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 2856 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 2857 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 2858 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 2859 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2860 | Repairing and reconditioning of 60 HP HSC Motor including all material,labour,etc at Anaikudam BS |
| 2861 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 2862 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 2863 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 2864 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 2865 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 2866 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 2867 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 2868 | Supply and delivery of Driven End and Non Driven End bearings |
| 2869 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2870 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour,etc at Infiltration Well |
| 2871 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2872 | Transporting the pumpset. |
| 2873 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2874 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2875 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2876 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2877 | Repair of Starter ATS 40 HP |
| 2878 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2879 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2880 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2881 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2882 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2883 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2884 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2885 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2886 | Repair of Starter Star & Delta 12.50 HP |
| 2887 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2888 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2889 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2890 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2891 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2892 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2893 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2894 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2895 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2896 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2897 | Supply and delivery of the following Electrical works:consumable items |
| 2898 | Volt meter SR 96 600 V-AC |
| 2899 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2900 | LED Outdoor fittings a)30 W LED street light fitting |
| 2901 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 2902 | Supply and delivery of fully automatic air break ATS starter 60HP as per IS8544 PART IV etc complete as directed/ |
| 2903 | Supply and delivery of fully automatic air break ATS starter 40HP as per IS8544 PART IV etc complete as directed/TWAD SR 2025-26 |
| 2904 | Supply and delivery of MCCB for following capacity |
| 2905 | 400 Amp 3 Pole for incoming including Terminal rotary handle |
| 2906 | 250 Amp 3 Pole for 40 HP Pump set Head work & Booster including Terminal rotary handle |
| 2907 | 100 Amp 3 Pole for 12.5 HP Pump set including Terminal rotary handle |
| 2908 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 2909 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 2910 | 50mm Dia GI Pipe |
| 2911 | Sump Cleaning |
| 2912 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 2913 | 3.00 LL capacity of Collection sump @ Kodalikaruppur HW |
| 2914 | 3.00 LL capacity of sump @ Anaikudam BS |
| 2915 | 300mm AC CL15 pipe |
| 2916 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 2917 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 2918 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 2919 | Leak and Burst works |
| 2920 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2921 | 300mm AC CL15 pipe |
| 2922 | 350mm PSC pipe |
| 2923 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2924 | 300mm AC CL 15 pipe |
| 2925 | 350mm PSC pipe |
| 2926 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 2927 | 150mm CI Pipe |
| 2928 | 300mm AC CL 15 Pipe |
| 2929 | 350mm PSC pipe |
| 2930 | Repairs & Renewals |
| 2931 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2932 | Repairing and reconditioning of 40 HP HSC Motor including all material,labour,etc at Kodalikaruppur HW |
| 2933 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 2934 | Transportation charges for conveying the motor including loading and unloading charges. |
| 2935 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 2936 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 2937 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 2938 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 2939 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2940 | Repairing and reconditioning of 40 HP HSC Pump including all material,labour,etc at Kodalikaruppur HW |
| 2941 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 2942 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 2943 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 2944 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 2945 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 2946 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 2947 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 2948 | Supply and delivery of Driven End and Non Driven End bearings |
| 2949 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2950 | Repairing and reconditioning of 60 HP HSC Motor including all material,labour,etc at Anaikudam BS |
| 2951 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 2952 | Transportation charges for conveying the motor including loading and unloading charges. |
| 2953 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 2954 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 2955 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 2956 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 2957 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2958 | Repairing and reconditioning of 60 HP HSC Motor including all material,labour,etc at Anaikudam BS |
| 2959 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 2960 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 2961 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 2962 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 2963 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 2964 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 2965 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 2966 | Supply and delivery of Driven End and Non Driven End bearings |
| 2967 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 2968 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour,etc at Infiltration Well |
| 2969 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 2970 | Transporting the pumpset. |
| 2971 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 2972 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 2973 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 2974 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 2975 | Repair of Starter ATS 40 HP |
| 2976 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 2977 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 2978 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 2979 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2980 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2981 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2982 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2983 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2984 | Repair of Starter Star & Delta 12.50 HP |
| 2985 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 2986 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 2987 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 2988 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 2989 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 2990 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 2991 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 2992 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 2993 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 2994 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 2995 | Supply and delivery of the following Electrical works:consumable items |
| 2996 | Volt meter SR 96 600 V-AC |
| 2997 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 2998 | LED Outdoor fittings a)30 W LED street light fittings |
| 2999 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 3000 | Supply and delivery of fully automatic air break ATS starter 60HP as per IS8544 PART IV etc complete as directed/TWAD SR 2025-26 |
| 3001 | Supply and delivery of fully automatic air break ATS starter 40HP as per IS8544 PART IV etc complete as directed/TWAD SR 2025-26 |
| 3002 | Supply and delivery of MCCB for following capacity |
| 3003 | 400 Amp 3 Pole for incoming including Terminal rotary handle |
| 3004 | 250 Amp 3 Pole for 40 HP Pump set Head work & Booster including Terminal rotary handle |
| 3005 | 100 Amp 3 Pole for 12.5 HP Pump set including Terminal rotary handle |
| 3006 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 3007 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 3008 | 50mm Dia GI Pipe |
| 3009 | Sump Cleaning |
| 3010 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 3011 | 3.00 LL capacity of Collection sump @ Kodalikaruppur HW |
| 3012 | 3.00 LL capacity of sump @ Anaikudam BS |
| 3013 | 300mm AC CL15 pipe |
| 3014 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 3015 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 3016 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 3017 | Leak and Burst works |
| 3018 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3019 | 300mm AC CL15 pipe |
| 3020 | 350mm PSC pipe |
| 3021 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3022 | 300mm AC CL 15 pipe |
| 3023 | 350mm PSC pipe |
| 3024 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3025 | 150mm CI Pipe |
| 3026 | 300mm AC CL 15 Pipe |
| 3027 | 350mm PSC pipe |
| 3028 | Repairs & Renewals |
| 3029 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3030 | Repairing and reconditioning of 40 HP HSC Motor including all material,labour,etc at Kodalikaruppur HW |
| 3031 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3032 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3033 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3034 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3035 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3036 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3037 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3038 | Repairing and reconditioning of 40 HP HSC Pump including all material,labour,etc at Kodalikaruppur HW |
| 3039 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3040 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 3041 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3042 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3043 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3044 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3045 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3046 | Supply and delivery of Driven End and Non Driven End bearings |
| 3047 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3048 | Repairing and reconditioning of 60 HP HSC Motor including all material,labour,etc at Anaikudam BS |
| 3049 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3050 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3051 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3052 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3053 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3054 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3055 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3056 | Repairing and reconditioning of 60 HP HSC Motor including all material,labour,etc at Anaikudam BS |
| 3057 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3058 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 3059 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3060 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3061 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3062 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3063 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3064 | Supply and delivery of Driven End and Non Driven End bearings |
| 3065 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3066 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour,etc at Infiltration Well |
| 3067 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3068 | Transporting the pumpset. |
| 3069 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3070 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3071 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3072 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3073 | Repair of Starter ATS 40 HP |
| 3074 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3075 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3076 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3077 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3078 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3079 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3080 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3081 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3082 | Repair of Starter Star & Delta 12.50 HP |
| 3083 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3084 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3085 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3086 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3087 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3088 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3089 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3090 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3091 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3092 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3093 | Supply and delivery of the following Electrical works:consumable items |
| 3094 | Volt meter SR 96 600 V-AC |
| 3095 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 3096 | LED Outdoor fittings a)30 W LED street light fittings |
| 3097 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 3098 | Supply and delivery of fully automatic air break ATS starter 60HP as per IS8544 PART IV etc complete as directed/TWAD SR 2025-26 |
| 3099 | Supply and delivery of fully automatic air break ATS starter 40HP as per IS8544 PART IV etc complete as directed/TWAD SR 2025-26 |
| 3100 | Supply and delivery of MCCB for following capacity |
| 3101 | 400 Amp 3 Pole for incoming including Terminal rotary handle |
| 3102 | 250 Amp 3 Pole for 40 HP Pump set Head work & Booster including Terminal rotary handle |
| 3103 | 100 Amp 3 Pole for 12.5 HP Pump set including Terminal rotary handle |
| 3104 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 3105 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 3106 | 50mm Dia GI Pipe |
| 3107 | Sump Cleaning |
| 3108 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 3109 | 3.00 LL capacity of Collection sump @ Kodalikaruppur HW |
| 3110 | 3.00 LL capacity of sump @ Anaikudam BS |
| 3111 | 300mm AC CL15 pipe |
| 3112 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 3113 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 3114 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 3115 | Leak and Burst works |
| 3116 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3117 | 200mm AC pipe |
| 3118 | 250mm AC pipe |
| 3119 | 250mm CI pipe |
| 3120 | 300mm CI pipe |
| 3121 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3122 | 200mm AC pipe |
| 3123 | 250mm AC pipe |
| 3124 | 250mm DI pipe |
| 3125 | 250mm CI pipe |
| 3126 | 300mm CI pipe |
| 3127 | 300mm DI pipe |
| 3128 | 63mm PVC 4KSC pipe |
| 3129 | 90mm PVC 4KSC Pipe |
| 3130 | 110mm PVC 4KSC Pipe |
| 3131 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3132 | 250mm AC pipe |
| 3133 | 250mm CI pipe |
| 3134 | 250mm DI pipe |
| 3135 | 300mm CI pipe |
| 3136 | 300mm DI pipe |
| 3137 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3138 | 300mm MS Pipe Below GL |
| 3139 | 300mm MS Pipe Above GL |
| 3140 | Repairs & Renewals |
| 3141 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3142 | Repairing and reconditioning of 50 HP VT Motor including all material,labour,etc at Kodalikaruppur Headworks - Motor |
| 3143 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3144 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 3145 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 3146 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3147 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3148 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 3149 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3150 | Repairing and reconditioning of 50 HP VT Pump including all material,labour,etc at Kodalikaruppur Headworks - Pump |
| 3151 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 3152 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 3153 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 3154 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 3155 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 3156 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 3157 | Repairing and reconditioning of 50 HP VT Motor including all material,labour,etc at Kodalikaruppur Headworks - Materials Supply |
| 3158 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3159 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3160 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 3161 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 3162 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 3163 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3164 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3165 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3166 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3167 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 3168 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 3169 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 3170 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 3171 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 3172 | Repairing and reconditioning of 20 HP Submersible openwell Pumpset at Kodalikaruppur HW - Motor |
| 3173 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3174 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3175 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3176 | Transporting charges for Submersible pumpset |
| 3177 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3178 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc at Udayarpalayam sump - Motor |
| 3179 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3180 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3181 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3182 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3183 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3184 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3185 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3186 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc at Udayarpalayam sump - Pump |
| 3187 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3188 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 3189 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3190 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3191 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3192 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3193 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3194 | Supply and delivery of Driven End and Non Driven End bearings |
| 3195 | Repairing and reconditioning of 50 HP HSCMotor including all material,labour,etc at Anaikudam Booster Station - Motor |
| 3196 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3197 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3198 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3199 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3200 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3201 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3202 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3203 | Repairing and reconditioning of 50 HP HSCMotor including all material,labour,etc at Anaikudam Booster Station - Pump |
| 3204 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3205 | Transportation charges for conveying the Pump including loading and unloading charges. |
| 3206 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3207 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3208 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3209 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3210 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3211 | Supply and delivery of Driven End and Non Driven End bearings |
| 3212 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour,etc |
| 3213 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3214 | Transporting the pumpset. |
| 3215 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3216 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3217 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3218 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3219 | Repair of Starter ATS 50 HP |
| 3220 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3221 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3222 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3223 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3224 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3225 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3226 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3227 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 3228 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 3229 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3230 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3231 | Repair of Starter ATS 20 HP |
| 3232 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3233 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3234 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3235 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3236 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3237 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3238 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3239 | Repair of Starter Star & Delta 12.50 HP |
| 3240 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3241 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3242 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3243 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3244 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3245 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3246 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3247 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3248 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3249 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3250 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 3251 | Supply and delivery of the following Electrical works:consumable items |
| 3252 | Volt meter SR 96 600 V-AC |
| 3253 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 3254 | LED Outdoor fittings a)30 W LED street light fittings |
| 3255 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 3256 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers |
| 3257 | 50mm Dia GI Pipe |
| 3258 | 80mm Dia GI Pipe |
| 3259 | Sump Cleaning |
| 3260 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 3261 | 3.00 LL capacity of Collection sump @ Kodalikaruppur HW |
| 3262 | 0.30 LL capacity of sump @ Anaikudam BS |
| 3263 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 3264 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 3265 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 3266 | Leak and Burst works |
| 3267 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3268 | 200mm AC pipe |
| 3269 | 250mm AC pipe |
| 3270 | 250mm CI pipe |
| 3271 | 300mm CI pipe |
| 3272 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3273 | 200mm AC pipe |
| 3274 | 250mm AC pipe |
| 3275 | 250mm DI pipe |
| 3276 | 250mm CI pipe |
| 3277 | 300mm CI pipe |
| 3278 | 300mm DI pipe |
| 3279 | 63mm PVC 4KSC pipe |
| 3280 | 90mm PVC 4KSC Pipe |
| 3281 | 110mm PVC 4KSC Pipe |
| 3282 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3283 | 250mm AC pipe |
| 3284 | 250mm CI pipe |
| 3285 | 250mm DI pipe |
| 3286 | 300mm CI pipe |
| 3287 | 300mm DI pipe |
| 3288 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3289 | 300mm MS Pipe Below GL |
| 3290 | 300mm MS Pipe Above GL |
| 3291 | Repairs & Renewals |
| 3292 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3293 | Repairing and reconditioning of 50 HP VT Motor including all material,labour,etc at Kodalikaruppur Headworks - Motor |
| 3294 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3295 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 3296 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 3297 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3298 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3299 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 3300 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3301 | Repairing and reconditioning of 50 HP VT Pump including all material,labour,etc at Kodalikaruppur Headworks - Pump |
| 3302 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 3303 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 3304 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 3305 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 3306 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 3307 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 3308 | Repairing and reconditioning of 50 HP VT Motor including all material,labour,etc at Kodalikaruppur Headworks - Materials Supply |
| 3309 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3310 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3311 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 3312 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 3313 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 3314 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3315 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3316 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3317 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3318 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 3319 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 3320 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 3321 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 3322 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 3323 | Repairing and reconditioning of 20 HP Submersible openwell Pumpset at Kodalikaruppur HW - Motor |
| 3324 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3325 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3326 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3327 | Transporting charges for Submersible pumpset |
| 3328 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3329 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc at Udayarpalayam sump - Motor |
| 3330 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3331 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3332 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3333 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3334 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3335 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3336 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3337 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc at Udayarpalayam sump - Pump |
| 3338 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3339 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 3340 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3341 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3342 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3343 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3344 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3345 | Supply and delivery of Driven End and Non Driven End bearings |
| 3346 | Repairing and reconditioning of 50 HP HSCMotor including all material,labour,etc at Anaikudam Booster Station - Motor |
| 3347 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3348 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3349 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3350 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3351 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3352 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3353 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3354 | Repairing and reconditioning of 50 HP HSCMotor including all material,labour,etc at Anaikudam Booster Station - Pump |
| 3355 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3356 | Transportation charges for conveying the Pump including loading and unloading charges. |
| 3357 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3358 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3359 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3360 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3361 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3362 | Supply and delivery of Driven End and Non Driven End bearings |
| 3363 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour,etc |
| 3364 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3365 | Transporting the pumpset. |
| 3366 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3367 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3368 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3369 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3370 | Repair of Starter ATS 50 HP |
| 3371 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3372 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3373 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3374 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3375 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3376 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3377 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3378 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 3379 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 3380 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3381 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3382 | Repair of Starter ATS 20 HP |
| 3383 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3384 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3385 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3386 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3387 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3388 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3389 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3390 | Repair of Starter Star & Delta 12.50 HP |
| 3391 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3392 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3393 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3394 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3395 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3396 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3397 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3398 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3399 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3400 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3401 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 3402 | Supply and delivery of the following Electrical works:consumable items |
| 3403 | Volt meter SR 96 600 V-AC |
| 3404 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 3405 | LED Outdoor fittings a)30 W LED street light fittings |
| 3406 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 3407 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 3408 | 50mm Dia GI Pipe |
| 3409 | 80mm Dia GI Pipe |
| 3410 | Sump Cleaning |
| 3411 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 3412 | 3.00 LL capacity of Collection sump @ Kodalikaruppur HW |
| 3413 | 0.30 LL capacity of sump @ Anaikudam BS |
| 3414 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 3415 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 3416 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 3417 | Leak and Burst works |
| 3418 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3419 | 200mm AC pipe |
| 3420 | 250mm AC pipe |
| 3421 | 250mm CI pipe |
| 3422 | 300mm CI pipe |
| 3423 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3424 | 200mm AC pipe |
| 3425 | 250mm AC pipe |
| 3426 | 250mm DI pipe |
| 3427 | 250mm CI pipe |
| 3428 | 300mm CI pipe |
| 3429 | 300mm DI pipe |
| 3430 | 63mm PVC 4KSC pipe |
| 3431 | 90mm PVC 4KSC Pipe |
| 3432 | 110mm PVC 4KSC Pipe |
| 3433 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3434 | 250mm AC pipe |
| 3435 | 250mm CI pipe |
| 3436 | 250mm DI pipe |
| 3437 | 300mm CI pipe |
| 3438 | 300mm DI pipe |
| 3439 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3440 | 300mm MS Pipe Below GL |
| 3441 | 300mm MS Pipe Above GL |
| 3442 | Repairs & Renewals |
| 3443 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3444 | Repairing and reconditioning of 50 HP VT Motor including all material,labour,etc at Kodalikaruppur Headworks - Motor |
| 3445 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3446 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 3447 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 3448 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3449 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3450 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 3451 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3452 | Repairing and reconditioning of 50 HP VT Pump including all material,labour,etc at Kodalikaruppur Headworks - Pump |
| 3453 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 3454 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 3455 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 3456 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 3457 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 3458 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 3459 | Repairing and reconditioning of 50 HP VT Motor including all material,labour,etc at Kodalikaruppur Headworks - Materials Supply |
| 3460 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3461 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3462 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 3463 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 3464 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 3465 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3466 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3467 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3468 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3469 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 3470 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 3471 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 3472 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 3473 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 3474 | Repairing and reconditioning of 20 HP Submersible openwell Pumpset at Kodalikaruppur HW - Motor |
| 3475 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3476 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3477 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3478 | Transporting charges for Submersible pumpset |
| 3479 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3480 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc at Udayarpalayam sump - Motor |
| 3481 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3482 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3483 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3484 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3485 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3486 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3487 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3488 | Repairing and reconditioning of 20 HP HSC Motor including all material,labour,etc at Udayarpalayam sump - Pump |
| 3489 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3490 | Transportation charges for conveying the Pump assembly including loading and unloading charges. |
| 3491 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3492 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3493 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3494 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3495 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3496 | Supply and delivery of Driven End and Non Driven End bearings |
| 3497 | Repairing and reconditioning of 50 HP HSCMotor including all material,labour,etc at Anaikudam Booster Station - Motor |
| 3498 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3499 | Transportation charges for conveying the motor including loading and unloading charges. |
| 3500 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3501 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3502 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3503 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3504 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3505 | Repairing and reconditioning of 50 HP HSCMotor including all material,labour,etc at Anaikudam Booster Station - Pump |
| 3506 | Charges for removing and reassembly the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3507 | Transportation charges for conveying the Pump including loading and unloading charges. |
| 3508 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3509 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3510 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3511 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3512 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3513 | Supply and delivery of Driven End and Non Driven End bearings |
| 3514 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour,etc |
| 3515 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3516 | Transporting the pumpset. |
| 3517 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3518 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3519 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3520 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3521 | Repair of Starter ATS 50 HP |
| 3522 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3523 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3524 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3525 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3526 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3527 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3528 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3529 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 3530 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 3531 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3532 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3533 | Repair of Starter ATS 20 HP |
| 3534 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3535 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3536 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3537 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3538 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3539 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3540 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3541 | Repair of Starter Star & Delta 12.50 HP |
| 3542 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3543 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3544 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3545 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3546 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3547 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3548 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3549 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3550 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3551 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3552 | Supply and delivery of PVC Insulated 3 core flat type copper cable-6 sq.mm |
| 3553 | Supply and delivery of the following Electrical works:consumable items |
| 3554 | Volt meter SR 96 600 V-AC |
| 3555 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 3556 | LED Outdoor fittings a)30 W LED street light fittings |
| 3557 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 3558 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 3559 | 50mm Dia GI Pipe |
| 3560 | 80mm Dia GI Pipe |
| 3561 | Sump Cleaning |
| 3562 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 3563 | 3.00 LL capacity of Collection sump @ Kodalikaruppur HW |
| 3564 | 0.30 LL capacity of sump @ Anaikudam BS |
| 3565 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 3566 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 3567 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 3568 | Leak and Burst works |
| 3569 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3570 | 150mm AC pipe |
| 3571 | 200mm AC pipe |
| 3572 | 250mm AC pipe |
| 3573 | 350mm PSC pipe |
| 3574 | 400mm PSC pipe |
| 3575 | 450mm PSC pipe |
| 3576 | 600mm PSC pipe |
| 3577 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3578 | 50mm 6 ksc PVC Pipes |
| 3579 | 63mm 4 ksc PVC Pipes |
| 3580 | 75mm 4 ksc PVC Pipes |
| 3581 | 90mm 4 ksc PVC Pipes |
| 3582 | 110mm 4 ksc PVC Pipes |
| 3583 | 140mm 4 ksc PVC Pipes |
| 3584 | 160mm 4 ksc PVC Pipes |
| 3585 | 150mm AC pipe |
| 3586 | 200mm AC pipe |
| 3587 | 250mm AC pipe |
| 3588 | 350mm PSC pipe |
| 3589 | 400mm PSC pipe |
| 3590 | 450mm PSC pipe |
| 3591 | 600mm PSC pipe |
| 3592 | 63mm HDPE PN6 |
| 3593 | 75mm HDPE PN6 |
| 3594 | 90mm HDPE PN6 |
| 3595 | 110mm HDPE PN6 |
| 3596 | 140mm HDPE PN6 |
| 3597 | 160mm HDPE PN6 |
| 3598 | 200mm HDPE PN6 |
| 3599 | 250mm HDPE PN6 |
| 3600 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3601 | 50mm 6 ksc PVC Pipes |
| 3602 | 63mm 4 ksc PVC Pipes |
| 3603 | 75mm 4 ksc PVC Pipes |
| 3604 | 90mm 4 ksc PVC Pipes |
| 3605 | 110mm 4 ksc PVC Pipes |
| 3606 | 140mm 4 ksc PVC Pipes |
| 3607 | 160mm 4 ksc PVC Pipes |
| 3608 | 150mm AC pipe |
| 3609 | 200mm AC pipe |
| 3610 | 250mm AC pipe |
| 3611 | 350mm PSC pipe |
| 3612 | 400mm PSC pipe |
| 3613 | 450mm PSC pipe |
| 3614 | 600mm PSC pipe |
| 3615 | 63mm HDPE PN6 |
| 3616 | 75mm HDPE PN6 |
| 3617 | 90mm HDPE PN6 |
| 3618 | 110mm HDPE PN6 |
| 3619 | 140mm HDPE PN6 |
| 3620 | 160mm HDPE PN6 |
| 3621 | 200mm HDPE PN6 |
| 3622 | 250mm HDPE PN6 |
| 3623 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 3624 | MS Pipe Leak Below GL |
| 3625 | 300mm MS Pipe |
| 3626 | 350mm MS Pipe |
| 3627 | 400 mm MS pipe |
| 3628 | 450 mm MS pipe |
| 3629 | 600 mm MS pipe |
| 3630 | MS Pipe Leak Above GL |
| 3631 | 300mm MS Pipe |
| 3632 | 350mm MS Pipe |
| 3633 | 400 mm MS pipe |
| 3634 | 450 mm MS pipe |
| 3635 | 600 mm MS pipe |
| 3636 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3637 | Repairing and reconditioning of 125 HP VT Motor with replacement of motor including all material, labour etc., |
| 3638 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3639 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 3640 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 3641 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3642 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3643 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 3644 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3645 | Transportation charges for conveying the motor from work shop to pumping Station |
| 3646 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 3647 | Repairing and reconditioning of 125 HP VT Pump labour charges,etc |
| 3648 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 3649 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 3650 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 3651 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 3652 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 3653 | Transportation charges for conveying the VT Pump bowl assembly from our work shop to Collector Well Pump room including usage of trolley along the Foot bridge and Van |
| 3654 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 3655 | Re errection of reconditioned stuffing box, new Head shaft, Discharge head and Motor, fixing the Rachet load bearing assembly including filling of required 90 grade oil and Connecting the 440V AC incoming Cable to the Motor Terminal and fixing new rope in the rope gland and Checking Motor Pumpset Alignment and Rotation and testing with load etc.,Complete |
| 3656 | Repair works of 125 HP VT Pump (Supply of Materials) |
| 3657 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3658 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 3659 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 3660 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 3661 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 3662 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3663 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3664 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 3665 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 3666 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 3667 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 3668 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 3669 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 3670 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 3671 | Repairing and reconditioning of 7.5 HP Openwell submersible Pumpset including all material, labour etc., |
| 3672 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3673 | Transporting the pumpset from Pump House to work shop. |
| 3674 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3675 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3676 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3677 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 3678 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3679 | Repairing and reconditioning of 167.50 HP HSC Motor including all material,labour,etc |
| 3680 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3681 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 3682 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3683 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3684 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3685 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3686 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3687 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 3688 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 3689 | Repairing and reconditioning of 167.50 HP HSC Pump including all material,labour,etc |
| 3690 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3691 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 3692 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3693 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3694 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3695 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3696 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3697 | Supply and delivery of Driven End and Non Driven End bearings |
| 3698 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3699 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 3700 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 3701 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 3702 | Attending the repair works in 11 KV/ 433 V Transformer - 315KVA at T.Palur Booster |
| 3703 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 3704 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 3705 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 3706 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 3707 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 3708 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 3709 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 3710 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 3711 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 3712 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 3713 | Charges for Eart Pit Value Checking with Certificate |
| 3714 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 3715 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 3716 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 3717 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 3718 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 3719 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 3720 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 3721 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 3722 | Supply and delivery of Drop Out fuse fixing unit set |
| 3723 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 3724 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 3725 | Supply and delivery of Silica gel |
| 3726 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 3727 | Repairing and reconditioning of 125 HP HSC Motor including all material,labour,etc |
| 3728 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3729 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 3730 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3731 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3732 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3733 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3734 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3735 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 3736 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 3737 | Repairing and reconditioning of 125 HP HSC Pump including all material, labour etc., |
| 3738 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3739 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 3740 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3741 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3742 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3743 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3744 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3745 | Supply and delivery of Driven End and Non Driven End bearings |
| 3746 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3747 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 3748 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 3749 | Attending the repair works in 11 KV/ 433 V Transformer - 200KVA at Jayankondam Booster |
| 3750 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 3751 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 3752 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 3753 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 3754 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 3755 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 3756 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 3757 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 3758 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 3759 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 3760 | Charges for Eart Pit Value Checking with Certificate |
| 3761 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 3762 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 3763 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 3764 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 3765 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 3766 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 3767 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 3768 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 3769 | Supply and delivery of Drop Out fuse fixing unit set |
| 3770 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 3771 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 3772 | Supply and delivery of Silica gel |
| 3773 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 3774 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 3775 | Repairing and reconditioning of 30 HP HSC Motor including all material, labour etc., |
| 3776 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3777 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 3778 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3779 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3780 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3781 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3782 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3783 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 3784 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 3785 | Repairing and reconditioning of 30 HP HSC Pump including all material, labour etc., |
| 3786 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3787 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 3788 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3789 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3790 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3791 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3792 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3793 | Supply and delivery of Driven End and Non Driven End bearings |
| 3794 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3795 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 3796 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 3797 | Repairing and reconditioning of 40 HP HSC Motor including all material, labour etc., |
| 3798 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 3799 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 3800 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 3801 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 3802 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 3803 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 3804 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3805 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 3806 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 3807 | Repairing and reconditioning of 40 HP HSC Pump including all material, labour etc., at Variyankaval Hospital sump |
| 3808 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 3809 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 3810 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 3811 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 3812 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 3813 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 3814 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 3815 | Supply and delivery of Driven End and Non Driven End bearings |
| 3816 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 3817 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 3818 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 3819 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour etc., |
| 3820 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3821 | Transporting the pumpset from Pump House to work shop. |
| 3822 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3823 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3824 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3825 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 3826 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3827 | Repairing and reconditioning of 15 HP Monoblock Pumpset including all material, labour, etc., |
| 3828 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 3829 | Transporting the pumpset from the Pumping Station to work shop. |
| 3830 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 3831 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 3832 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3833 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 3834 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 3835 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 3836 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 3837 | Repairing and reconditioning of 3HP Submersible Pumpset including all material, labour etc., |
| 3838 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3839 | Transporting the pumpset from Pump House to work shop. |
| 3840 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3841 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3842 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3843 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 3844 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3845 | Repairing and reconditioning of 20 HP Submersible Pumpset including all material, labour etc., |
| 3846 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3847 | Transporting the pumpset from Pump House to work shop. |
| 3848 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3849 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3850 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3851 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 3852 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3853 | Repairing and reconditioning of 5HP Centrifugal Pumpset including all material, labour etc., |
| 3854 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 3855 | Transporting the pumpset from the Pumping Station to work shop. |
| 3856 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 3857 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 3858 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3859 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 3860 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 3861 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 3862 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 3863 | Repairing and reconditioning of 5HP Submersible Pumpset including all material, labour, etc at Edaiyakuruchi |
| 3864 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3865 | Transporting the pumpset from Pump House to work shop. |
| 3866 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3867 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3868 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3869 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 3870 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3871 | Repairing and reconditioning of 7.50 HP Centrifugal Pumpset including all material, labour etc., |
| 3872 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 3873 | Transporting the pumpset from the Pumping Station to work shop. |
| 3874 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 3875 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 3876 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3877 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 3878 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 3879 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 3880 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 3881 | Repairing and reconditioning of 2HP Monoblock Pumpset including all material, labour etc., |
| 3882 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 3883 | Transporting the pumpset from the Pumping Station to work shop. |
| 3884 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 3885 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 3886 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3887 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 3888 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 3889 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 3890 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 3891 | Repairing and reconditioning of 2HP Submersible Pumpset including all material, labour etc., |
| 3892 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 3893 | Transporting the pumpset from Pump House to work shop. |
| 3894 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3895 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 3896 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 3897 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 3898 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 3899 | Repairing and reconditioning of 1HP Monoblock Pumpset including all material, labour etc., |
| 3900 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 3901 | Transporting the pumpset from the Pumping Station to work shop. |
| 3902 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 3903 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 3904 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3905 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 3906 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 3907 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 3908 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 3909 | Repairing and reconditioning of 3 HP Monoblock Pumpset including all material, labour etc., |
| 3910 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 3911 | Transporting the pumpset from the Pumping Station to work shop. |
| 3912 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 3913 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 3914 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 3915 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 3916 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 3917 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 3918 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 3919 | Attending repair works in Soft starter 145 HP |
| 3920 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 3921 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 3922 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 3923 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 3924 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3925 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 3926 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3927 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3928 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3929 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 3930 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 3931 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3932 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3933 | Attending repair works in Soft starter 190 HP |
| 3934 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 3935 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 3936 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 3937 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 3938 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3939 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 3940 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3941 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3942 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3943 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 3944 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 3945 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3946 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3947 | Attending repair works in ATS starter 40 HP |
| 3948 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3949 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 3950 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3951 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3952 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3953 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3954 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3955 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3956 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3957 | Attending repair works in ATS starter 30 HP |
| 3958 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 3959 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 3960 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 3961 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 3962 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3963 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3964 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3965 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3966 | Attending repair works in Star Delta starter 20 HP |
| 3967 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3968 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3969 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3970 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3971 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3972 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3973 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3974 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3975 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3976 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3977 | Attending repair works in Star Delta starter 12.5 HP |
| 3978 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3979 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3980 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3981 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3982 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3983 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3984 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3985 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3986 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3987 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3988 | Attending repair works in Star Delta starter 7.5 HP |
| 3989 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 3990 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 3991 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 3992 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 3993 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 3994 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 3995 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 3996 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 3997 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 3998 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 3999 | Attending repair works in DOL starter 5 HP |
| 4000 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4001 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4002 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4003 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4004 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4005 | Attending repair works in DOL starter 3 HP |
| 4006 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4007 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4008 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4009 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4010 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4011 | Attending repair works in DOL starter 2 HP |
| 4012 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4013 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4014 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4015 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4016 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4017 | Attending repair works in DOL starter 1 HP |
| 4018 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4019 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4020 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4021 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4022 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4023 | Supply and delivery of PVC Insulated 3 core flat type copper cable - 6 sq.mm |
| 4024 | Supply and delivery of the following Electrical works:consumable items |
| 4025 | Volt meter SR 96 600 V-AC |
| 4026 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 4027 | LED Outdoor fittings a)30 W LED street light fittings |
| 4028 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 4029 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 4030 | 50mm GI Pipe |
| 4031 | 65mm GI Pipe |
| 4032 | 80mm GI Pipe |
| 4033 | 100mm GI Pipe |
| 4034 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 4035 | 300mm Sluice Valve |
| 4036 | 250mm Sluice Valve |
| 4037 | 200mm Sluice Valve |
| 4038 | 150mm Sluice Valve |
| 4039 | 100mm Sluice Valve |
| 4040 | 80mm Sluice Valve |
| 4041 | Replacement of non functioning unserviceble Gun Metal Gate valve without affecting existing alignment by using contractor tools excluding the cost of valve but including required length of GI nipple, coupling etc., complete |
| 4042 | 80mm GM Valve |
| 4043 | 65mm GM Valve |
| 4044 | 50mm GM Valve |
| 4045 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 4046 | 100mm Air Valve |
| 4047 | 80mm Air Valve |
| 4048 | 50mm Air Valve |
| 4049 | 25mm Air Valve |
| 4050 | Sump Cleaning |
| 4051 | Charges for cleaning the sumps of TWAD Board by clearing the sludge and disposing it to near by boundary of the sump site including baling out the sludge water by using diesel pumpset of required capacity and removing the algae and scaling by scrapping, flushing the sump finally with bleaching powder and spreading bleaching powder around the sump , etc., complete and as directed by the departmental officers |
| 4052 | 1.00 LL capacity of sump @ Thoothur |
| 4053 | 8.00 LL capacity of sump @ T,Palur Booster |
| 4054 | 0.20 LL capacity of sump @ Angarayanallur |
| 4055 | 8.00 LL capacity of sump @ Jayankondam Booster |
| 4056 | 0.20 LL capacity of sump @ Elaiyur Mariamman koil |
| 4057 | 0.20 LL capacity of sump @ Elaiyur Colony |
| 4058 | 0.20 LL capacity of sump @ Variyankaval East |
| 4059 | 1.00 LL capacity of sump @ Variyankaval GH |
| 4060 | 1.50 LL capacity of sump @ Devanur |
| 4061 | 1.00 LL capacity of sump @ Kuvagam |
| 4062 | 2.00 LL capacity of sump @ Edayakurichi |
| 4063 | 2.00 LL capacity of sump @ Agneespuram |
| 4064 | 2.00 LL capacity of sump @ Koovathur |
| 4065 | 1.00 LL capacity of sump @ Ayyur |
| 4066 | 2.00 LL capacity of sump @ Kumilakuzhi |
| 4067 | 1.00 LL capacity of sump @ Silambur |
| 4068 | 1.00 LL capacity of sump @ Pukkuzhi |
| 4069 | 0.60LL capacity of sump @ Alagapuram OHT |
| 4070 | 2.00 LL capacity of sump @ Alagapuram Naidu Street |
| 4071 | 0.60 LL capacity of sump @ Alagapuram Colony |
| 4072 | 1.00 LL capacity of sump @ Agaram |
| 4073 | 1.00 LL capacity of sump @ Kavarapalayam |
| 4074 | 0.30 LL capacity of sump @ Manakollai |
| 4075 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 4076 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 4077 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 4078 | Leak and Burst works |
| 4079 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4080 | 150mm AC pipe |
| 4081 | 200mm AC pipe |
| 4082 | 250mm AC pipe |
| 4083 | 350mm PSC pipe |
| 4084 | 400mm PSC pipe |
| 4085 | 450mm PSC pipe |
| 4086 | 600mm PSC pipe |
| 4087 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4088 | 50mm 6 ksc PVC Pipes |
| 4089 | 63mm 4 ksc PVC Pipes |
| 4090 | 75mm 4 ksc PVC Pipes |
| 4091 | 90mm 4 ksc PVC Pipes |
| 4092 | 110mm 4 ksc PVC Pipes |
| 4093 | 140mm 4 ksc PVC Pipes |
| 4094 | 160mm 4 ksc PVC Pipes |
| 4095 | 150mm AC pipe |
| 4096 | 200mm AC pipe |
| 4097 | 250mm AC pipe |
| 4098 | 350mm PSC pipe |
| 4099 | 400mm PSC pipe |
| 4100 | 450mm PSC pipe |
| 4101 | 600mm PSC pipe |
| 4102 | 63mm HDPE PN6 |
| 4103 | 75mm HDPE PN6 |
| 4104 | 90mm HDPE PN6 |
| 4105 | 110mm HDPE PN6 |
| 4106 | 140mm HDPE PN6 |
| 4107 | 160mm HDPE PN6 |
| 4108 | 200mm HDPE PN6 |
| 4109 | 250mm HDPE PN6 |
| 4110 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4111 | 50mm 6 ksc PVC Pipes |
| 4112 | 63mm 4 ksc PVC Pipes |
| 4113 | 75mm 4 ksc PVC Pipes |
| 4114 | 90mm 4 ksc PVC Pipes |
| 4115 | 110mm 4 ksc PVC Pipes |
| 4116 | 140mm 4 ksc PVC Pipes |
| 4117 | 160mm 4 ksc PVC Pipes |
| 4118 | 150mm AC pipe |
| 4119 | 200mm AC pipe |
| 4120 | 250mm AC pipe |
| 4121 | 350mm PSC pipe |
| 4122 | 400mm PSC pipe |
| 4123 | 450mm PSC pipe |
| 4124 | 600mm PSC pipe |
| 4125 | 63mm HDPE PN6 |
| 4126 | 75mm HDPE PN6 |
| 4127 | 90mm HDPE PN6 |
| 4128 | 110mm HDPE PN6 |
| 4129 | 140mm HDPE PN6 |
| 4130 | 160mm HDPE PN6 |
| 4131 | 200mm HDPE PN6 |
| 4132 | 250mm HDPE PN6 |
| 4133 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4134 | MS Pipe Leak Below GL |
| 4135 | 300mm MS Pipe |
| 4136 | 350mm MS Pipe |
| 4137 | 400 mm MS pipe |
| 4138 | 450 mm MS pipe |
| 4139 | 600 mm MS pipe |
| 4140 | MS Pipe Leak Above GL |
| 4141 | 300mm MS Pipe |
| 4142 | 350mm MS Pipe |
| 4143 | 400 mm MS pipe |
| 4144 | 450 mm MS pipe |
| 4145 | 600 mm MS pipe |
| 4146 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 4147 | Repairing and reconditioning of 125 HP VT Motor with replacement of motor including all material, labour etc., |
| 4148 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4149 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 4150 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 4151 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4152 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4153 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 4154 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4155 | Transportation charges for conveying the motor from work shop to pumping Station |
| 4156 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4157 | Repairing and reconditioning of 125 HP VT Pump labour charges,etc |
| 4158 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 4159 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 4160 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 4161 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 4162 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 4163 | Transportation charges for conveying the VT Pump bowl assembly from our work shop to Collector Well Pump room including usage of trolley along the Foot bridge and Van |
| 4164 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 4165 | Re errection of reconditioned stuffing box, new Head shaft, Discharge head and Motor, fixing the Rachet load bearing assembly including filling of required 90 grade oil and Connecting the 440V AC incoming Cable to the Motor Terminal and fixing new rope in the rope gland and Checking Motor Pumpset Alignment and Rotation and testing with load etc.,Complete |
| 4166 | Repair works of 125 HP VT Pump (Supply of Materials) |
| 4167 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 4168 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 4169 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 4170 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 4171 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 4172 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 4173 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 4174 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 4175 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 4176 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 4177 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 4178 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 4179 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 4180 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 4181 | Repairing and reconditioning of 7.5 HP Openwell submersible Pumpset including all material, labour etc., |
| 4182 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4183 | Transporting the pumpset from Pump House to work shop. |
| 4184 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4185 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4186 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4187 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4188 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4189 | Repairing and reconditioning of 167.50 HP HSC Motor including all material,labour,etc |
| 4190 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4191 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4192 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4193 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4194 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4195 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4196 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4197 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4198 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4199 | Repairing and reconditioning of 167.50 HP HSC Pump including all material,labour,etc |
| 4200 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4201 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4202 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4203 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4204 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4205 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4206 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4207 | Supply and delivery of Driven End and Non Driven End bearings |
| 4208 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4209 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4210 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4211 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4212 | Attending the repair works in 11 KV/ 433 V Transformer - 315KVA at T.Palur Booster |
| 4213 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 4214 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 4215 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 4216 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 4217 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 4218 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 4219 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 4220 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 4221 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 4222 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 4223 | Charges for Eart Pit Value Checking with Certificate |
| 4224 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 4225 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 4226 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 4227 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 4228 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 4229 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 4230 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 4231 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4232 | Supply and delivery of Drop Out fuse fixing unit set |
| 4233 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 4234 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 4235 | Supply and delivery of Silica gel |
| 4236 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 4237 | Repairing and reconditioning of 125 HP HSC Motor including all material,labour,etc |
| 4238 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4239 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4240 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4241 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4242 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4243 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4244 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4245 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4246 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4247 | Repairing and reconditioning of 125 HP HSC Pump including all material, labour etc., |
| 4248 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4249 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4250 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4251 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4252 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4253 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4254 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4255 | Supply and delivery of Driven End and Non Driven End bearings |
| 4256 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4257 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4258 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4259 | Attending the repair works in 11 KV/ 433 V Transformer - 200KVA at Jayankondam Booster |
| 4260 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 4261 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 4262 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 4263 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 4264 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 4265 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 4266 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 4267 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 4268 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 4269 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 4270 | Charges for Eart Pit Value Checking with Certificate |
| 4271 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 4272 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 4273 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 4274 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 4275 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 4276 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 4277 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 4278 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4279 | Supply and delivery of Drop Out fuse fixing unit set |
| 4280 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 4281 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 4282 | Supply and delivery of Silica gel |
| 4283 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 4284 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4285 | Repairing and reconditioning of 30 HP HSC Motor including all material, labour etc., |
| 4286 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4287 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4288 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4289 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4290 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4291 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4292 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4293 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4294 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4295 | Repairing and reconditioning of 30 HP HSC Pump including all material, labour etc., |
| 4296 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4297 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4298 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4299 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4300 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4301 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4302 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4303 | Supply and delivery of Driven End and Non Driven End bearings |
| 4304 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4305 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4306 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4307 | Repairing and reconditioning of 40 HP HSC Motor including all material, labour etc., |
| 4308 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4309 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4310 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4311 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4312 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4313 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4314 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4315 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4316 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4317 | Repairing and reconditioning of 40 HP HSC Pump including all material, labour etc., at Variyankaval Hospital sump |
| 4318 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4319 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4320 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4321 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4322 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4323 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4324 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4325 | Supply and delivery of Driven End and Non Driven End bearings |
| 4326 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4327 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4328 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4329 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour etc., |
| 4330 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4331 | Transporting the pumpset from Pump House to work shop. |
| 4332 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4333 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4334 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4335 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4336 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4337 | Repairing and reconditioning of 15 HP Monoblock Pumpset including all material, labour, etc., |
| 4338 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4339 | Transporting the pumpset from the Pumping Station to work shop. |
| 4340 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4341 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4342 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4343 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4344 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4345 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4346 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4347 | Repairing and reconditioning of 3HP Submersible Pumpset including all material, labour etc., |
| 4348 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4349 | Transporting the pumpset from Pump House to work shop. |
| 4350 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4351 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4352 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4353 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4354 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4355 | Repairing and reconditioning of 20 HP Submersible Pumpset including all material, labour etc., |
| 4356 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4357 | Transporting the pumpset from Pump House to work shop. |
| 4358 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4359 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4360 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4361 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4362 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4363 | Repairing and reconditioning of 5HP Centrifugal Pumpset including all material, labour etc., |
| 4364 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4365 | Transporting the pumpset from the Pumping Station to work shop. |
| 4366 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4367 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4368 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4369 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4370 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4371 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4372 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4373 | Repairing and reconditioning of 5HP Submersible Pumpset including all material, labour, etc at Edaiyakuruchi |
| 4374 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4375 | Transporting the pumpset from Pump House to work shop. |
| 4376 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4377 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4378 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4379 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4380 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4381 | Repairing and reconditioning of 7.50 HP Centrifugal Pumpset including all material, labour etc., |
| 4382 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4383 | Transporting the pumpset from the Pumping Station to work shop. |
| 4384 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4385 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4386 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4387 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4388 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4389 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4390 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4391 | Repairing and reconditioning of 2HP Monoblock Pumpset including all material, labour etc., |
| 4392 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4393 | Transporting the pumpset from the Pumping Station to work shop. |
| 4394 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4395 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4396 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4397 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4398 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4399 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4400 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4401 | Repairing and reconditioning of 2HP Submersible Pumpset including all material, labour etc., |
| 4402 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4403 | Transporting the pumpset from Pump House to work shop. |
| 4404 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4405 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4406 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4407 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4408 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4409 | Repairing and reconditioning of 1HP Monoblock Pumpset including all material, labour etc., |
| 4410 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4411 | Transporting the pumpset from the Pumping Station to work shop. |
| 4412 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4413 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4414 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4415 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4416 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4417 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4418 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4419 | Repairing and reconditioning of 3 HP Monoblock Pumpset including all material, labour etc., |
| 4420 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4421 | Transporting the pumpset from the Pumping Station to work shop. |
| 4422 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4423 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4424 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4425 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4426 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4427 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4428 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4429 | Attending repair works in Soft starter 145 HP |
| 4430 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 4431 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 4432 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 4433 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 4434 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4435 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 4436 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4437 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4438 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4439 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 4440 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 4441 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4442 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4443 | Attending repair works in Soft starter 190 HP |
| 4444 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 4445 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 4446 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 4447 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 4448 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4449 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 4450 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4451 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4452 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4453 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 4454 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 4455 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4456 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4457 | Attending repair works in ATS starter 40 HP |
| 4458 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 4459 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 4460 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 4461 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 4462 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4463 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4464 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4465 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4466 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4467 | Attending repair works in ATS starter 30 HP |
| 4468 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 4469 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 4470 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 4471 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 4472 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4473 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4474 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4475 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4476 | Attending repair works in Star Delta starter 20 HP |
| 4477 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 4478 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4479 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4480 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4481 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 4482 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4483 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 4484 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4485 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4486 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4487 | Attending repair works in Star Delta starter 12.5 HP |
| 4488 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 4489 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4490 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4491 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4492 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 4493 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4494 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 4495 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4496 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4497 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4498 | Attending repair works in Star Delta starter 7.5 HP |
| 4499 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 4500 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4501 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4502 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4503 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 4504 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4505 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 4506 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4507 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4508 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4509 | Attending repair works in DOL starter 5 HP |
| 4510 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4511 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4512 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4513 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4514 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4515 | Attending repair works in DOL starter 3 HP |
| 4516 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4517 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4518 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4519 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4520 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4521 | Attending repair works in DOL starter 2 HP |
| 4522 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4523 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4524 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4525 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4526 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4527 | Attending repair works in DOL starter 1 HP |
| 4528 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 4529 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4530 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4531 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4532 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4533 | Supply and delivery of PVC Insulated 3 |
| 4534 | Supply and delivery of the following Electrical works:consumable items |
| 4535 | Volt meter SR 96 600 V-AC |
| 4536 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 4537 | LED Outdoor fittings a)30 W LED street light fittings |
| 4538 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 4539 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 4540 | 50mm GI Pipe |
| 4541 | 65mm GI Pipe |
| 4542 | 80mm GI Pipe |
| 4543 | 100mm GI Pipe |
| 4544 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 4545 | 300mm Sluice Valve |
| 4546 | 250mm Sluice Valve |
| 4547 | 200mm Sluice Valve |
| 4548 | 150mm Sluice Valve |
| 4549 | 100mm Sluice Valve |
| 4550 | 80mm Sluice Valve |
| 4551 | Replacement of non functioning unserviceble Gun Metal Gate valve without affecting existing alignment by using contractor tools excluding the cost of valve but including required length of GI nipple, coupling etc., complete |
| 4552 | 80mm GM Valve |
| 4553 | 65mm GM Valve |
| 4554 | 50mm GM Valve |
| 4555 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 4556 | 100mm Air Valve |
| 4557 | 80mm Air Valve |
| 4558 | 50mm Air Valve |
| 4559 | 25mm Air Valve |
| 4560 | Sump Cleaning |
| 4561 | Charges for cleaning the sumps of TWAD Board by clearing the sludge and disposing it to near by boundary of the sump site including baling out the sludge water by using diesel pumpset of required capacity and removing the algae and scaling by scrapping, flushing the sump finally with bleaching powder and spreading bleaching powder around the sump , etc., complete and as directed by the departmental officers |
| 4562 | 1.00 LL capacity of sump @ Thoothur |
| 4563 | 8.00 LL capacity of sump @ T,Palur Booster |
| 4564 | 0.20 LL capacity of sump @ Angarayanallur |
| 4565 | 8.00 LL capacity of sump @ Jayankondam Booster |
| 4566 | 0.20 LL capacity of sump @ Elaiyur Mariamman koil |
| 4567 | 0.20 LL capacity of sump @ Elaiyur Colony |
| 4568 | 0.20 LL capacity of sump @ Variyankaval East |
| 4569 | 1.00 LL capacity of sump @ Variyankaval GH |
| 4570 | 1.50 LL capacity of sump @ Devanur |
| 4571 | 1.00 LL capacity of sump @ Kuvagam |
| 4572 | 2.00 LL capacity of sump @ Edayakurichi |
| 4573 | 2.00 LL capacity of sump @ Agneespuram |
| 4574 | 2.00 LL capacity of sump @ Koovathur |
| 4575 | 1.00 LL capacity of sump @ Ayyur |
| 4576 | 2.00 LL capacity of sump @ Kumilakuzhi |
| 4577 | 1.00 LL capacity of sump @ Silambur |
| 4578 | 1.00 LL capacity of sump @ Pukkuzhi |
| 4579 | 0.60LL capacity of sump @ Alagapuram OHT |
| 4580 | 2.00 LL capacity of sump @ Alagapuram Naidu Street |
| 4581 | 0.60 LL capacity of sump @ Alagapuram Colony |
| 4582 | 1.00 LL capacity of sump @ Agaram |
| 4583 | 1.00 LL capacity of sump @ Kavarapalayam |
| 4584 | 0.30 LL capacity of sump @ Manakollai |
| 4585 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 4586 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 4587 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 4588 | Leak and Burst works |
| 4589 | Attending Collar Leaks in the AC pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4590 | 150mm AC pipe |
| 4591 | 200mm AC pipe |
| 4592 | 250mm AC pipe |
| 4593 | 350mm PSC pipe |
| 4594 | 400mm PSC pipe |
| 4595 | 450mm PSC pipe |
| 4596 | 600mm PSC pipe |
| 4597 | Attending Minor Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4598 | 50mm 6 ksc PVC Pipes |
| 4599 | 63mm 4 ksc PVC Pipes |
| 4600 | 75mm 4 ksc PVC Pipes |
| 4601 | 90mm 4 ksc PVC Pipes |
| 4602 | 110mm 4 ksc PVC Pipes |
| 4603 | 140mm 4 ksc PVC Pipes |
| 4604 | 160mm 4 ksc PVC Pipes |
| 4605 | 150mm AC pipe |
| 4606 | 200mm AC pipe |
| 4607 | 250mm AC pipe |
| 4608 | 350mm PSC pipe |
| 4609 | 400mm PSC pipe |
| 4610 | 450mm PSC pipe |
| 4611 | 600mm PSC pipe |
| 4612 | 63mm HDPE PN6 |
| 4613 | 75mm HDPE PN6 |
| 4614 | 90mm HDPE PN6 |
| 4615 | 110mm HDPE PN6 |
| 4616 | 140mm HDPE PN6 |
| 4617 | 160mm HDPE PN6 |
| 4618 | 200mm HDPE PN6 |
| 4619 | 250mm HDPE PN6 |
| 4620 | Attending Major Burst in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4621 | 50mm 6 ksc PVC Pipes |
| 4622 | 63mm 4 ksc PVC Pipes |
| 4623 | 75mm 4 ksc PVC Pipes |
| 4624 | 90mm 4 ksc PVC Pipes |
| 4625 | 110mm 4 ksc PVC Pipes |
| 4626 | 140mm 4 ksc PVC Pipes |
| 4627 | 160mm 4 ksc PVC Pipes |
| 4628 | 150mm AC pipe |
| 4629 | 200mm AC pipe |
| 4630 | 250mm AC pipe |
| 4631 | 350mm PSC pipe |
| 4632 | 400mm PSC pipe |
| 4633 | 450mm PSC pipe |
| 4634 | 600mm PSC pipe |
| 4635 | 63mm HDPE PN6 |
| 4636 | 75mm HDPE PN6 |
| 4637 | 90mm HDPE PN6 |
| 4638 | 110mm HDPE PN6 |
| 4639 | 140mm HDPE PN6 |
| 4640 | 160mm HDPE PN6 |
| 4641 | 200mm HDPE PN6 |
| 4642 | 250mm HDPE PN6 |
| 4643 | Attending Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II.(The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 4644 | MS Pipe Leak Below GL |
| 4645 | 300mm MS Pipe |
| 4646 | 350mm MS Pipe |
| 4647 | 400 mm MS pipe |
| 4648 | 450 mm MS pipe |
| 4649 | 600 mm MS pipe |
| 4650 | MS Pipe Leak Above GL |
| 4651 | 300mm MS Pipe |
| 4652 | 350mm MS Pipe |
| 4653 | 400 mm MS pipe |
| 4654 | 450 mm MS pipe |
| 4655 | 600 mm MS pipe |
| 4656 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 4657 | Repairing and reconditioning of 125 HP VT Motor with replacement of motor including all material, labour etc., |
| 4658 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4659 | Transportation charges for conveying the motor from the Station to Our work shop including loading and unloading charges. |
| 4660 | Labour Charges for removing the two end side cover with fan arrangements and Dismantling the damaged NDE Side ball Bearing from the motor after removing the Rachet assembly load bearing safely and Fixing the New ball Bearing in the appropriate place with required lubricants without any damage to the motor shaft and winding after deducting the old damaged materials. |
| 4661 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4662 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4663 | Supply and delivery of Non Driven End Deep Grove ball Bearing SKF Make suitable for the Squirrel Gage Induction Motor. |
| 4664 | Labour Charges fixing the NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4665 | Transportation charges for conveying the motor from work shop to pumping Station |
| 4666 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4667 | Repairing and reconditioning of 125 HP VT Pump labour charges,etc |
| 4668 | Charges for Removing the Hollow shaft Squirrel cage Induction Motor after disconnecting the Power supply Cable, Discharge Head, Head Shaft and Stuffing Box by using contractor tools at Collector Well / Collection Sump |
| 4669 | Charges for removing the all Column pipes of VT Pumpset each 1.5 m / 2.00 m to length and bowl assemblly for attending Pump repair works |
| 4670 | Transportation charges for conveying the VT Pump bowl assembly from Collector Well Pump room to Work Shop including usage of trolley along the Foot bridge and Van |
| 4671 | Reconditioning of Stuffing Box for providing bronze bush suitable for fixing thr Rope Gland and Head Shaft to avoid frequent damaging of rope and to avoid spreading of more leakage water from the Rope Gland including lath works etc., complete. |
| 4672 | Charges for Lathe work of reconditioning of Pump SS Shaft with balancing, SS Bushes and sleeves, charges for Spider bore nd outer dimension phase out lath works, reconditioning of impeller and impeller ring & charges fixing the bearing and bronze bushes in the bowl assembly including correct setting of impeller allignment etc complete |
| 4673 | Transportation charges for conveying the VT Pump bowl assembly from our work shop to Collector Well Pump room including usage of trolley along the Foot bridge and Van |
| 4674 | Charges for reassembling the all Column pipes of Turbine Pump set and bowl assemblly after attending Pump repair works in the proper allignment after attending the cleaning and painting work in the coloumn pipe and body of the bowl assembly |
| 4675 | Re errection of reconditioned stuffing box, new Head shaft, Discharge head and Motor, fixing the Rachet load bearing assembly including filling of required 90 grade oil and Connecting the 440V AC incoming Cable to the Motor Terminal and fixing new rope in the rope gland and Checking Motor Pumpset Alignment and Rotation and testing with load etc.,Complete |
| 4676 | Repair works of 125 HP VT Pump (Supply of Materials) |
| 4677 | Supply and Delivery of SS 410 New Pump Head Shaft for required mm and required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 4678 | Supply and Delivery of SS 410 New Pump Line Shaft for required mm and required length. (including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) |
| 4679 | Supply and delivery of stuffing box brone bush suitable for the Discharge Head assembly |
| 4680 | Supply and Delivery of Required TVS Bolt , Nut and Washer for Bowl Assembly and all Column Pipe for inplace of Wornout Bolt and Nuts after deducting the cost of scrap materials and as Directed by TWAD Board Officers. |
| 4681 | Supply and Delivery of Line shaft SS Coupling with Bush (including Raw Materials, Machining , Polishing etc., Complete) |
| 4682 | Supply and Delivery of SS Sleeves Suitable for the Line Shaft for Inplace of Wornout SS Sleeves after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 4683 | Supply and Delivery of Spider Rubber Bush made in Hard Rubber and Finishing to Suit in Between the Casting Spider and Line shaft inplace of wornout Rubber Bush after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 4684 | Supply and Delivery of Bronze Bush Bearing Suitable for Bowl Assembly and Pump Shaft inplace of wornout bronze Bush Bearing after deducting the cost of scrap materials as directed by TWAD Board Officers. |
| 4685 | Supply and Delivery of 1.Bronze Bush Bearing Suitable for the Bowl Assembly (Top Side) 2. Bronze Bush Bearing Suitable for the Bell Mouth (Bottom) for inplace of wornout Bronze Bush Bearings after deducting the cost of scrap materials as Directed by TWAD Board Officers. |
| 4686 | Supply and delivery of MS Seamless required size of Coloumn pipe suitable for the VT Pumpset |
| 4687 | Supply and delivery of spider suitable for the coloumn pipe including cost of Raw Materials, welding, polishing etc., complete as directed by TWAD officers |
| 4688 | Supply and delivery of new intermedia ring (Prosperous bronze metal) between bowl assembly and as directed by TWAD officers |
| 4689 | Supply and delivery of new bowl shaft for required size for required length.(including Charge for Lathe Works, Grinding, Polishing, Threading, Key Way and other works etc.,Complete) and as directed by TWAD officers |
| 4690 | Supply and delivery of Top Load Bearing with Ratchet assembly including Required Grade lubricating components |
| 4691 | Repairing and reconditioning of 7.5 HP Openwell submersible Pumpset including all material, labour etc., |
| 4692 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4693 | Transporting the pumpset from Pump House to work shop. |
| 4694 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4695 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4696 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4697 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4698 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4699 | Repairing and reconditioning of 167.50 HP HSC Motor including all material,labour,etc |
| 4700 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4701 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4702 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4703 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4704 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4705 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4706 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4707 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4708 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4709 | Repairing and reconditioning of 167.50 HP HSC Pump including all material,labour,etc |
| 4710 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4711 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4712 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4713 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4714 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4715 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4716 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4717 | Supply and delivery of Driven End and Non Driven End bearings |
| 4718 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4719 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4720 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4721 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4722 | Attending the repair works in 11 KV/ 433 V Transformer - 315KVA at T.Palur Booster |
| 4723 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 4724 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 4725 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 4726 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 4727 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 4728 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 4729 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 4730 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 4731 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 4732 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 4733 | Charges for Eart Pit Value Checking with Certificate |
| 4734 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 4735 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 4736 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 4737 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 4738 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 4739 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 4740 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 4741 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4742 | Supply and delivery of Drop Out fuse fixing unit set |
| 4743 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 4744 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 4745 | Supply and delivery of Silica gel |
| 4746 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 4747 | Repairing and reconditioning of 125 HP HSC Motor including all material,labour,etc |
| 4748 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4749 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4750 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4751 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4752 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4753 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4754 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4755 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4756 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4757 | Repairing and reconditioning of 125 HP HSC Pump including all material, labour etc., |
| 4758 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4759 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4760 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4761 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4762 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4763 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4764 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4765 | Supply and delivery of Driven End and Non Driven End bearings |
| 4766 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4767 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4768 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4769 | Attending the repair works in 11 KV/ 433 V Transformer - 200KVA at Jayankondam Booster |
| 4770 | Charges for removing the Transformer from the plinth after disconnecting the incomming & outgoing supply terminations, earthing, neutral connection in the Transformer loading to vehicle with mobile grane and conveying to workshop unloading the transformer with mobile crane as per site condition and as directed by TWAD Board Officers. |
| 4771 | Charges for disconnecting the incomming & outgoing (LT & HT Side) supply terminations, earthing, neutral connection in the Transformer and drain out the oil from the conservator Tank and Transformer tank up to the required level and stacking the containers to attend the repair works/ Oil leakages and as directed by TWAD Board Officers. |
| 4772 | Charges Opening the Transformer Top cover after disconnecting the inside terminal connections, weakening / damaged bushes, brash stud bolt & Nuts and lifting Transformer core & winding without damages etc., complete. |
| 4773 | Charges for cleaning the winding coils of the Transformer free from moisture and cleaning the inside walls of the Transformer by using required new Transformer oil without any damage to the Transformer Coil |
| 4774 | Charges for fixing the required capacity brass LT terminal bush 3nos, copper connecting plate,3 nos using necessary bushes, screws bolt nuts etc., complete |
| 4775 | Charges for re-fixing the Transformer Top cover with conservator tank on the Transformer and connecting with all inside terminal connections including HT terminals by using required bolt & nuts and filling the tapped oil upto the mark of level indicator and charging the transformers, testing with load etc., complete |
| 4776 | Charges for rewinding of Three phase of 11KV/22KV/ 433V Transformer in the suitable core assembly including charges for removing the burnt coil and allining of core assembly and including required insulating materials etc complete after deducting the cost burned scrap. |
| 4777 | Charges for improving of IR Value of Transformer using electric oven - Heat Champer (LT winding, HT winding and Transformer core) etc., complete as directed by TWAD Board officers. |
| 4778 | Charges for two coats of painting the Transformer as directed by TWAD Board officers. |
| 4779 | Charges for two coats of painting the 6 Pole Structure and yard fencing etc,. complete as directed by TWAD Board officers. |
| 4780 | Charges for Eart Pit Value Checking with Certificate |
| 4781 | Charges for 11KV/433V Transformer loading to vehicle with mobile grane and conveying to Pumphouse Unloading the above transformer with mobile crane Re-erection of transformer with cable termination earthing and neutral connection testing of No Load and Load testing at pumphouse as per site condition and existing arrangements and as directed by TWAD Board Officers. |
| 4782 | Charges for transformer oil filtration using hot air vacuum filtering unit up to the required BDV value and submitting test result of both BDV and Acidity etc .complete and as directed by TWAD board officers. |
| 4783 | Supply and delivery of required size of LT Brass rod with terminal bushing with 4 no of nuts, washers and insulating sleeves etc., complete |
| 4784 | Supply and delivery of required capacity copper,connecting plate for cable termination . |
| 4785 | Supply and delivery of required size copper HT terminal rod with Bushing and required Bolt & Nuts with washers |
| 4786 | Supply and Delivery of Cork Packing Sheet, Cork Bush for LT and HT side, oil level Indicator as directed by TWAD Board officers after deducting the cost of old scraps |
| 4787 | Supply and delivery of new LT/HT Coil made EC Grade DP coveriong copper wire for winding of 11KV/22KV/433V Transformer and required insulating materials etc., complete |
| 4788 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4789 | Supply and delivery of Drop Out fuse fixing unit set |
| 4790 | Supply, delivery and fixing of Drop Out fuse Top Contact and bottom Contact |
| 4791 | Supply and delivery of Breather with Silica gel of required size for the Transfomer |
| 4792 | Supply and delivery of Silica gel |
| 4793 | Supply and delivery of 11 KV / 22 KV Lightning Arrestor |
| 4794 | Supply of transformer oil grade “A” for using cooling purpose of transformer winding AS per IS 335/1983, HT 11KV/ 22KV/ 415 V transformer (including transport , loading an unloading etc complete) Directed by TWAD board officers. |
| 4795 | Repairing and reconditioning of 30 HP HSC Motor including all material, labour etc., |
| 4796 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4797 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4798 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4799 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4800 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4801 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4802 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4803 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4804 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4805 | Repairing and reconditioning of 30 HP HSC Pump including all material, labour etc., |
| 4806 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4807 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4808 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4809 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4810 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4811 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4812 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4813 | Supply and delivery of Driven End and Non Driven End bearings |
| 4814 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4815 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4816 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4817 | Repairing and reconditioning of 40 HP HSC Motor including all material, labour etc., |
| 4818 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 4819 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 4820 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 4821 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 4822 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 4823 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 4824 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4825 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 4826 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 4827 | Repairing and reconditioning of 40 HP HSC Pump including all material, labour etc., at Variyankaval Hospital sump |
| 4828 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 4829 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 4830 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 4831 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 4832 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 4833 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 4834 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 4835 | Supply and delivery of Driven End and Non Driven End bearings |
| 4836 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 4837 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 4838 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 4839 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour etc., |
| 4840 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4841 | Transporting the pumpset from Pump House to work shop. |
| 4842 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4843 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4844 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4845 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4846 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4847 | Repairing and reconditioning of 15 HP Monoblock Pumpset including all material, labour, etc., |
| 4848 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4849 | Transporting the pumpset from the Pumping Station to work shop. |
| 4850 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4851 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4852 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4853 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4854 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4855 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4856 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4857 | Repairing and reconditioning of 3HP Submersible Pumpset including all material, labour etc., |
| 4858 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4859 | Transporting the pumpset from Pump House to work shop. |
| 4860 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4861 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4862 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4863 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4864 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4865 | Repairing and reconditioning of 20 HP Submersible Pumpset including all material, labour etc., |
| 4866 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4867 | Transporting the pumpset from Pump House to work shop. |
| 4868 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4869 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4870 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4871 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4872 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4873 | Repairing and reconditioning of 5HP Centrifugal Pumpset including all material, labour etc., |
| 4874 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4875 | Transporting the pumpset from the Pumping Station to work shop. |
| 4876 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4877 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4878 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4879 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4880 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4881 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4882 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4883 | Repairing and reconditioning of 5HP Submersible Pumpset including all material, labour, etc at Edaiyakuruchi |
| 4884 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4885 | Transporting the pumpset from Pump House to work shop. |
| 4886 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4887 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4888 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4889 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4890 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4891 | Repairing and reconditioning of 7.50 HP Centrifugal Pumpset including all material, labour etc., |
| 4892 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4893 | Transporting the pumpset from the Pumping Station to work shop. |
| 4894 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4895 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4896 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4897 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4898 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4899 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4900 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4901 | Repairing and reconditioning of 2HP Monoblock Pumpset including all material, labour etc., |
| 4902 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4903 | Transporting the pumpset from the Pumping Station to work shop. |
| 4904 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4905 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4906 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4907 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4908 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4909 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4910 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4911 | Repairing and reconditioning of 2HP Submersible Pumpset including all material, labour etc., |
| 4912 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 4913 | Transporting the pumpset from Pump House to work shop. |
| 4914 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4915 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 4916 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 4917 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 4918 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 4919 | Repairing and reconditioning of 1HP Monoblock Pumpset including all material, labour etc., |
| 4920 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4921 | Transporting the pumpset from the Pumping Station to work shop. |
| 4922 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4923 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4924 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4925 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4926 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4927 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4928 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4929 | Repairing and reconditioning of 3 HP Monoblock Pumpset including all material, labour etc., |
| 4930 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 4931 | Transporting the pumpset from the Pumping Station to work shop. |
| 4932 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 4933 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 4934 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 4935 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 4936 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 4937 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 4938 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 4939 | Attending repair works in Soft starter 145 HP |
| 4940 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 4941 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 4942 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 4943 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 4944 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4945 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 4946 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4947 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4948 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4949 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 4950 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 4951 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4952 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4953 | Attending repair works in Soft starter 190 HP |
| 4954 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 4955 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 4956 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 4957 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 4958 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4959 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 4960 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4961 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4962 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4963 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 4964 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 4965 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4966 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4967 | Attending repair works in ATS starter 40 HP |
| 4968 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 4969 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 4970 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 4971 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 4972 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4973 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4974 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4975 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4976 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4977 | Attending repair works in ATS starter 30 HP |
| 4978 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 4979 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 4980 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 4981 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 4982 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4983 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4984 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4985 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4986 | Attending repair works in Star Delta starter 20 HP |
| 4987 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 4988 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 4989 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 4990 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 4991 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 4992 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 4993 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 4994 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 4995 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 4996 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 4997 | Attending repair works in Star Delta starter 12.5 HP |
| 4998 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 4999 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5000 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5001 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5002 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 5003 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5004 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 5005 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 5006 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5007 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5008 | Attending repair works in Star Delta starter 7.5 HP |
| 5009 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, CT Coil and PLA safety Relay suitable for the starter |
| 5010 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5011 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5012 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5013 | Supply and Delivery and fixing of required capacity Over load relay suitable for the starter as directed by TWAD Board officers. |
| 5014 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5015 | Replacement of Front Mounting unit including the cost of material (NO and NC Element) suitable for the starter as directed by TWAD Board Officers. |
| 5016 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 5017 | Replacement of of required amps Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5018 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5019 | Attending repair works in DOL starter 5 HP |
| 5020 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5021 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5022 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5023 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5024 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5025 | Attending repair works in DOL starter 3 HP |
| 5026 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5027 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5028 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5029 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5030 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5031 | Attending repair works in DOL starter 2 HP |
| 5032 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5033 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5034 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5035 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5036 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5037 | Attending repair works in DOL starter 1 HP |
| 5038 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5039 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5040 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5041 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5042 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5043 | Supply and delivery of PVC Insulated 3 core flat type copper cable - 6 sq.mm |
| 5044 | Supply and delivery of the following Electrical works:consumable items |
| 5045 | Volt meter SR 96 600 V-AC |
| 5046 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 5047 | LED Outdoor fittings a)30 W LED street light fittings |
| 5048 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking |
| 5049 | Supply and delivery of GI pipes (Medium) as per IS 1239/PART I/2004complete and as directed by the TWAD board officers. |
| 5050 | 50mm GI Pipe |
| 5051 | 65mm GI Pipe |
| 5052 | 80mm GI Pipe |
| 5053 | 100mm GI Pipe |
| 5054 | Charges for Repair and Reconditioning of the Sluice Valves and Air Valves fixed in the Pumping Main, Feeder Main and Branch Main including cost of all materials and labour charges etc., complete |
| 5055 | 300mm Sluice Valve |
| 5056 | 250mm Sluice Valve |
| 5057 | 200mm Sluice Valve |
| 5058 | 150mm Sluice Valve |
| 5059 | 100mm Sluice Valve |
| 5060 | 80mm Sluice Valve |
| 5061 | Replacement of non functioning unserviceble Gun Metal Gate valve without affecting existing alignment by using contractor tools excluding the cost of valve but including required length of GI nipple, coupling etc., complete |
| 5062 | 80mm GM Valve |
| 5063 | 65mm GM Valve |
| 5064 | 50mm GM Valve |
| 5065 | Repair and Reconditioning of the Double Air Valve / Single Chamber Air Release Valve including the Cost of Air Valve Ball, Rubber Washer and required Bolt & Nuts, etc., complete |
| 5066 | 100mm Air Valve |
| 5067 | 80mm Air Valve |
| 5068 | 50mm Air Valve |
| 5069 | 25mm Air Valve |
| 5070 | Sump Cleaning |
| 5071 | Charges for cleaning the sumps of TWAD Board by clearing the sludge and disposing it to near by boundary of the sump site including baling out the sludge water by using diesel pumpset of required capacity and removing the algae and scaling by scrapping, flushing the sump finally with bleaching powder and spreading bleaching powder around the sump , etc., complete and as directed by the departmental officers |
| 5072 | 1.00 LL capacity of sump @ Thoothur |
| 5073 | 8.00 LL capacity of sump @ T,Palur Booster |
| 5074 | 0.20 LL capacity of sump @ Angarayanallur |
| 5075 | 8.00 LL capacity of sump @ Jayankondam Booster |
| 5076 | 0.20 LL capacity of sump @ Elaiyur Mariamman koil |
| 5077 | 0.20 LL capacity of sump @ Elaiyur Colony |
| 5078 | 0.20 LL capacity of sump @ Variyankaval East |
| 5079 | 1.00 LL capacity of sump @ Variyankaval GH |
| 5080 | 1.50 LL capacity of sump @ Devanur |
| 5081 | 1.00 LL capacity of sump @ Kuvagam |
| 5082 | 2.00 LL capacity of sump @ Edayakurichi |
| 5083 | 2.00 LL capacity of sump @ Agneespuram |
| 5084 | 2.00 LL capacity of sump @ Koovathur |
| 5085 | 1.00 LL capacity of sump @ Ayyur |
| 5086 | 2.00 LL capacity of sump @ Kumilakuzhi |
| 5087 | 1.00 LL capacity of sump @ Silambur |
| 5088 | 1.00 LL capacity of sump @ Pukkuzhi |
| 5089 | 0.60LL capacity of sump @ Alagapuram OHT |
| 5090 | 2.00 LL capacity of sump @ Alagapuram Naidu Street |
| 5091 | 0.60 LL capacity of sump @ Alagapuram Colony |
| 5092 | 1.00 LL capacity of sump @ Agaram |
| 5093 | 1.00 LL capacity of sump @ Kavarapalayam |
| 5094 | 0.30 LL capacity of sump @ Manakollai |
| 5095 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 5096 | For the Year 2026-2027 (From 01.04.2026 to 31.03.2027) |
| 5097 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 5098 | Leak and Burst |
| 5099 | Attending Minor/ Major Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II. (The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 5100 | PVC / HDPE Pipes - Minor/ Circumferential Leak |
| 5101 | 63mm 4 ksc PVC Pipes |
| 5102 | 75mm 4 ksc PVC Pipes |
| 5103 | 90mm 4 ksc PVC Pipes |
| 5104 | 110mm 4 ksc PVC Pipes |
| 5105 | 140mm 4 ksc PVC Pipes |
| 5106 | 50mm 6 ksc PVC Pipes |
| 5107 | 63mm 6 ksc PVC Pipes |
| 5108 | 75mm 6 ksc PVC Pipes |
| 5109 | 90mm 6 ksc PVC Pipes |
| 5110 | 110mm 6 ksc PVC Pipes |
| 5111 | 140mm 6 ksc PVC Pipes |
| 5112 | 160mm 6 ksc PVC Pipes |
| 5113 | 160mm HDPE PN6 Pipes |
| 5114 | 250mm HDPE PN6 Pipes |
| 5115 | 280mm HDPE PN6 Pipes |
| 5116 | 315mm HDPE PN6 Pipes |
| 5117 | 355mm HDPE PN6 Pipes |
| 5118 | 160mm HDPE PN8 Pipes |
| 5119 | 355mm HDPE PN8 Pipes |
| 5120 | PVC / HDPE Pipes - Major Burst |
| 5121 | 63mm 4 ksc PVC Pipes |
| 5122 | 75mm 4 ksc PVC Pipes |
| 5123 | 90mm 4 ksc PVC Pipes |
| 5124 | 110mm 4 ksc PVC Pipes |
| 5125 | 140mm 4 ksc PVC Pipes |
| 5126 | 50mm 6 ksc PVC Pipes |
| 5127 | 63mm 6 ksc PVC Pipes |
| 5128 | 75mm 6 ksc PVC Pipes |
| 5129 | 90mm 6 ksc PVC Pipes |
| 5130 | 110mm 6 ksc PVC Pipes |
| 5131 | 140mm 6 ksc PVC Pipes |
| 5132 | 160mm 6 ksc PVC Pipes |
| 5133 | 160mm HDPE PN6 Pipes |
| 5134 | 250mm HDPE PN6 Pipes |
| 5135 | 280mm HDPE PN6 Pipes |
| 5136 | 315mm HDPE PN6 Pipes |
| 5137 | 355mm HDPE PN6 Pipes |
| 5138 | 160mm HDPE PN8 Pipes |
| 5139 | 355mm HDPE PN8 Pipes |
| 5140 | GI Pipes - Above GL |
| 5141 | 125 mm GI pipe |
| 5142 | 100 mm GI pipe |
| 5143 | 80 mm GI pipe |
| 5144 | 65mm GI pipe |
| 5145 | 50 mm GI pipe |
| 5146 | MS Pipes - Above GL |
| 5147 | 300mm MS |
| 5148 | 350mm MS |
| 5149 | DI - Minor/ Circumferential Leak |
| 5150 | 200mm DI |
| 5151 | 250mm DI |
| 5152 | Supply and delivery of GM gate vaves as per IS BS5154 and related IS specification complete and as directed by the TWAD board officers |
| 5153 | 50 mm GM Gate valve |
| 5154 | 65 mm GM Gate valve |
| 5155 | 80 mm GM Gate valve |
| 5156 | 50 mm GM NRV valve |
| 5157 | 65 mm GM NRV valve |
| 5158 | 80 mm GM NRV valve |
| 5159 | Repairing and reconditioning of Air Valve in pumping , booster and branch main |
| 5160 | 50mm DI Single Chamber Air release Valve |
| 5161 | 80mm DI Single Chamber Air release Valve |
| 5162 | 50mm CI Double Air Valve |
| 5163 | 40mm CI Double Air Valve |
| 5164 | 25mm CI Single Air Valve |
| 5165 | Supply and delivery of DI non return valve IS specification complete and as directed by the TWAD board officers. |
| 5166 | 50mm DI Non-Return Valve |
| 5167 | 65mm DI Non-Return Valve |
| 5168 | 80mm DI Non-Return Valve |
| 5169 | 100mm DI Non-Return Valve |
| 5170 | 250mm DI Non-Return Valve |
| 5171 | Supply and Delivery of MJ Collars 200mm |
| 5172 | REPAIR AND RENEWALS |
| 5173 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 5174 | Repairing and reconditioning of 100 HP HSC Motor including all material, labour, etc |
| 5175 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 5176 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 5177 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 5178 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 5179 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 5180 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 5181 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 5182 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 5183 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 5184 | Repairing and reconditioning of 100 HP HSC Pump including all material, labour, etc |
| 5185 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 5186 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 5187 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 5188 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 5189 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 5190 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 5191 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 5192 | Supply and delivery of Driven End and Non Driven End bearings |
| 5193 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 5194 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 5195 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 5196 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour, etc at Infiltration wells Head works |
| 5197 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5198 | Transporting the pumpset from Pump House to work shop. |
| 5199 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5200 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5201 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5202 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5203 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5204 | Repairing and reconditioning of 20 HP Submersible Pumpset including all material, labour, etc |
| 5205 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5206 | Transporting the pumpset from Pump House to work shop. |
| 5207 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5208 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5209 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5210 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5211 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5212 | Repairing and reconditioning of 4 HP and 3HP Submersible Pumpset including all material, labour, etc |
| 5213 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5214 | Transporting the pumpset from Pump House to work shop. |
| 5215 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5216 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5217 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5218 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5219 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5220 | Repairing and reconditioning of 1 HP Submersible Pumpset including all material, labour, etc |
| 5221 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5222 | Transporting the pumpset from Pump House to work shop. |
| 5223 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5224 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5225 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5226 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5227 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5228 | Repairing and reconditioning of 2 HP Submersible Pumpset including all material, labour, etc |
| 5229 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5230 | Transporting the pumpset from Pump House to work shop. |
| 5231 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5232 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5233 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5234 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5235 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5236 | Repairing and reconditioning of 1HP Centrifugal Monoblock Pumpset including all material, labour, etc at Keelaveli to Pattiyadi |
| 5237 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5238 | Transporting the pumpset from the Pumping Station to work shop. |
| 5239 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5240 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5241 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5242 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5243 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5244 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5245 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5246 | Repairing and reconditioning of 3 HP Centrifugal Monoblock Pumpset including all material,labour,etc |
| 5247 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5248 | Transporting the pumpset from the Pumping Station to work shop. |
| 5249 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5250 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5251 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5252 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5253 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5254 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5255 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5256 | Repairing and reconditioning of 2 HP Centrifugal Pumpset including all material,labour,etc at Kallathur SP to kallathur |
| 5257 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5258 | Transporting the pumpset from the Pumping Station to work shop. |
| 5259 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5260 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5261 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5262 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5263 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5264 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5265 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5266 | Attending the repair works in Soft Starter 100HP |
| 5267 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 5268 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 5269 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 5270 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 5271 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5272 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 5273 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5274 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5275 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5276 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 5277 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 5278 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 5279 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5280 | Repairing and reconditioning of ATS Starter 12.50 HP |
| 5281 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 5282 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 5283 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 5284 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 5285 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5286 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5287 | Repairing and reconditioning of ATS Starter 25 HP |
| 5288 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 5289 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 5290 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 5291 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 5292 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5293 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5294 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5295 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5296 | Repairing and reconditioning of DOL Starter 1 HP |
| 5297 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5298 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5299 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5300 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5301 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5302 | Repairing and reconditioning of DOL Starter 2 HP |
| 5303 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5304 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5305 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5306 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5307 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5308 | Repairing and reconditioning of DOL Starter 3 HP |
| 5309 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5310 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5311 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5312 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5313 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5314 | Replacement of Electrical items |
| 5315 | Volt meter SR 96 600 V-AC |
| 5316 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 5317 | LED Outdoor fittings a) 30 W LED street light fittings |
| 5318 | Supply, delivery and fixing of 200 AMPS porcelain Fuse unit (500V) with fuse |
| 5319 | Supply, delivery and fixing of 100 AMPS porcelain Fuse unit (500V) with fuse wire in the existing place inside the pump room for sump |
| 5320 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/ 440V 50 HZ conforming to ISS:2834 with ISI marking |
| 5321 | Sump Cleaning |
| 5322 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 5323 | 2.2 LL capacity of sump @ Head works |
| 5324 | 4.00 LL capacity of sump @ Vanathirayanpattiam |
| 5325 | 2.00 LL capacity of sump @ Kazhuvanthondi Booster |
| 5326 | 0.3 LL capacity of sump @ Pilichikuli, Cholakuruchi, Keelaveli |
| 5327 | 1.00 LL capacity of Stand Post @ Kallathur, Vankudy |
| 5328 | 1.50 LL capacity of Stand Post @ Periayavalaiyam, Radhapuram |
| 5329 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 5330 | 2,00,000 LPH |
| 5331 | 10,000 LPH |
| 5332 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 5333 | For the Year 2027-2028(From 01.04.2027 to 31.03.2028) |
| 5334 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 5335 | Leak and Burst |
| 5336 | Attending Minor/ Major Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II. (The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 5337 | PVC / HDPE Pipes - Minor/ Circumferential Leak |
| 5338 | 63mm 4 ksc PVC Pipes |
| 5339 | 75mm 4 ksc PVC Pipes |
| 5340 | 90mm 4 ksc PVC Pipes |
| 5341 | 110mm 4 ksc PVC Pipes |
| 5342 | 140mm 4 ksc PVC Pipes |
| 5343 | 50mm 6 ksc PVC Pipes |
| 5344 | 63mm 6 ksc PVC Pipes |
| 5345 | 75mm 6 ksc PVC Pipes |
| 5346 | 90mm 6 ksc PVC Pipes |
| 5347 | 110mm 6 ksc PVC Pipes |
| 5348 | 140mm 6 ksc PVC Pipes |
| 5349 | 160mm 6 ksc PVC Pipes |
| 5350 | 160mm HDPE PN6 Pipes |
| 5351 | 250mm HDPE PN6 Pipes |
| 5352 | 280mm HDPE PN6 Pipes |
| 5353 | 315mm HDPE PN6 Pipes |
| 5354 | 355mm HDPE PN6 Pipes |
| 5355 | 160mm HDPE PN8 Pipes |
| 5356 | 355mm HDPE PN8 Pipes |
| 5357 | PVC / HDPE Pipes - Major Burst |
| 5358 | 63mm 4 ksc PVC Pipes |
| 5359 | 75mm 4 ksc PVC Pipes |
| 5360 | 90mm 4 ksc PVC Pipes |
| 5361 | 110mm 4 ksc PVC Pipes |
| 5362 | 140mm 4 ksc PVC Pipes |
| 5363 | 50mm 6 ksc PVC Pipes |
| 5364 | 63mm 6 ksc PVC Pipes |
| 5365 | 75mm 6 ksc PVC Pipes |
| 5366 | 90mm 6 ksc PVC Pipes |
| 5367 | 110mm 6 ksc PVC Pipes |
| 5368 | 140mm 6 ksc PVC Pipes |
| 5369 | 160mm 6 ksc PVC Pipes |
| 5370 | 160mm HDPE PN6 Pipes |
| 5371 | 250mm HDPE PN6 Pipes |
| 5372 | 280mm HDPE PN6 Pipes |
| 5373 | 315mm HDPE PN6 Pipes |
| 5374 | 355mm HDPE PN6 Pipes |
| 5375 | 160mm HDPE PN8 Pipes |
| 5376 | 355mm HDPE PN8 Pipes |
| 5377 | GI Pipes - Above GL |
| 5378 | 125 mm GI pipe |
| 5379 | 100 mm GI pipe |
| 5380 | 80 mm GI pipe |
| 5381 | 65mm GI pipe |
| 5382 | 50 mm GI pipe |
| 5383 | MS Pipes - Above GL |
| 5384 | 300mm MS |
| 5385 | 350mm MS |
| 5386 | DI - Minor/ Circumferential Leak |
| 5387 | 200mm DI |
| 5388 | 250mm DI |
| 5389 | Supply and delivery of GM gate vaves as per IS BS5154 and related IS specification complete and as directed by the TWAD board officers. |
| 5390 | 50 mm GM Gate valve |
| 5391 | 65 mm GM Gate valve |
| 5392 | 80 mm GM Gate valve |
| 5393 | 50 mm GM NRV valve |
| 5394 | 65 mm GM NRV valve |
| 5395 | 80 mm GM NRV valve |
| 5396 | Repairing and reconditioning of Air Valve in pumping , booster and branch main |
| 5397 | 50mm DI Single Chamber Air release Valve |
| 5398 | 80mm DI Single Chamber Air release Valve |
| 5399 | 50mm CI Double Air Valve |
| 5400 | 40mm CI Double Air Valve |
| 5401 | 25mm CI Single Air Valve |
| 5402 | Supply and delivery of DI non return valve IS specification complete and as directed by the TWAD board officers. |
| 5403 | 50mm DI Non-Return Valve |
| 5404 | 65mm DI Non-Return Valve |
| 5405 | 80mm DI Non-Return Valve |
| 5406 | 100mm DI Non-Return Valve |
| 5407 | 250mm DI Non-Return Valve |
| 5408 | Supply and Delivery of MJ Collars 200mm |
| 5409 | REPAIR AND RENEWALS |
| 5410 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 5411 | Repairing and reconditioning of 100 HP HSC Motor including all material, labour, etc |
| 5412 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 5413 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 5414 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 5415 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 5416 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 5417 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 5418 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 5419 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 5420 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 5421 | Repairing and reconditioning of 100 HP HSC Pump including all material, labour, etc |
| 5422 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 5423 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 5424 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 5425 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 5426 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 5427 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 5428 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 5429 | Supply and delivery of Driven End and Non Driven End bearings |
| 5430 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 5431 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 5432 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 5433 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour, etc at Infiltration wells Head works |
| 5434 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5435 | Transporting the pumpset from Pump House to work shop. |
| 5436 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5437 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5438 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5439 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5440 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5441 | Repairing and reconditioning of 20 HP Submersible Pumpset including all material, labour, etc |
| 5442 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5443 | Transporting the pumpset from Pump House to work shop. |
| 5444 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5445 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5446 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5447 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5448 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5449 | Repairing and reconditioning of 4 HP and 3HP Submersible Pumpset including all material, labour, etc |
| 5450 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5451 | Transporting the pumpset from Pump House to work shop. |
| 5452 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5453 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5454 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5455 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5456 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5457 | Repairing and reconditioning of 1 HP Submersible Pumpset including all material, labour, etc |
| 5458 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5459 | Transporting the pumpset from Pump House to work shop. |
| 5460 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5461 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5462 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5463 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5464 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5465 | Repairing and reconditioning of 2 HP Submersible Pumpset including all material, labour, etc |
| 5466 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5467 | Transporting the pumpset from Pump House to work shop. |
| 5468 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5469 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5470 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5471 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5472 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5473 | Repairing and reconditioning of 1HP Centrifugal Monoblock Pumpset including all material, labour, etc at Keelaveli to Pattiyadi |
| 5474 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5475 | Transporting the pumpset from the Pumping Station to work shop. |
| 5476 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5477 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5478 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5479 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5480 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5481 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5482 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5483 | Repairing and reconditioning of 3 HP Centrifugal Monoblock Pumpset including all material,labour,etc |
| 5484 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5485 | Transporting the pumpset from the Pumping Station to work shop. |
| 5486 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5487 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5488 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5489 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5490 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5491 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5492 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5493 | Repairing and reconditioning of 2 HP Centrifugal Pumpset including all material,labour,etc at Kallathur SP to kallathur |
| 5494 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5495 | Transporting the pumpset from the Pumping Station to work shop. |
| 5496 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5497 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5498 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5499 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5500 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5501 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5502 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5503 | Attending the repair works in Soft Starter 100HP |
| 5504 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 5505 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 5506 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 5507 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 5508 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5509 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 5510 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5511 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5512 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5513 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 5514 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 5515 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 5516 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5517 | Repairing and reconditioning of ATS Starter 12.50 HP |
| 5518 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 5519 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 5520 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 5521 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 5522 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5523 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5524 | Repairing and reconditioning of ATS Starter 25 HP |
| 5525 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 5526 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 5527 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 5528 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 5529 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5530 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5531 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5532 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5533 | Repairing and reconditioning of DOL Starter 1 HP |
| 5534 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5535 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5536 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5537 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5538 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5539 | Repairing and reconditioning of DOL Starter 2 HP |
| 5540 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5541 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5542 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5543 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5544 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5545 | Repairing and reconditioning of DOL Starter 3 HP |
| 5546 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5547 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5548 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5549 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5550 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5551 | Replacement of Electrical items |
| 5552 | Volt meter SR 96 600 V-AC |
| 5553 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 5554 | LED Outdoor fittings a) 30 W LED street light fittings |
| 5555 | Supply, delivery and fixing of 200 AMPS porcelain Fuse unit (500V) with fuse |
| 5556 | Supply, delivery and fixing of 100 AMPS porcelain Fuse unit (500V) with fuse wire in the existing place inside the pump room for sump |
| 5557 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/ 440V 50 HZ conforming to ISS:2834 with ISI markingTWAD SR 2022-23/P.205 |
| 5558 | Sump Cleaning |
| 5559 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 5560 | 2.2 LL capacity of sump @ Head works |
| 5561 | 4.00 LL capacity of sump @ Vanathirayanpattiam |
| 5562 | 2.00 LL capacity of sump @ Kazhuvanthondi Booster |
| 5563 | 0.3 LL capacity of sump @ Pilichikuli, Cholakuruchi, Keelaveli |
| 5564 | 1.00 LL capacity of Stand Post @ Kallathur, Vankudy |
| 5565 | 1.50 LL capacity of Stand Post @ Periayavalaiyam, Radhapuram |
| 5566 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 5567 | 2,00,000 LPH |
| 5568 | 10,000 LPH |
| 5569 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. |
| 5570 | For the Year 2028-2029(From 01.04.2028 to 31.03.2029) |
| 5571 | Operation and Maintenance of the Electro Mechanical installations, equipements, components,pipelines valves and appurtenances,water retaining structuress including protection of all scheme components from damages /theft undertaking legal actions for such untoward incidents,preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earnmarked quantity of water to the beneficiaries as per stanndard operating procedures,Acts and rules in force and as directected by TWAD Board Oficers and excluding cost towards attending leak,burst repairs and replacement works to electro mechanical installations consumables for disinfection of water,cleaning of all water retaining structure. |
| 5572 | Leak and Burst |
| 5573 | Attending Minor/ Major Leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges etc complete with in the stipulated time limit as specified in clause 2.6.4 of General conditions of Contact-Part II. (The specifications for attending leaks has to be detailed based on the data prepared and rate approval obtained for each size and material of pipes.The specification has to be mentioned under the clause 1.7 of GCC-Part-I) |
| 5574 | PVC / HDPE Pipes - Minor/ Circumferential Leak |
| 5575 | 63mm 4 ksc PVC Pipes |
| 5576 | 75mm 4 ksc PVC Pipes |
| 5577 | 90mm 4 ksc PVC Pipes |
| 5578 | 110mm 4 ksc PVC Pipes |
| 5579 | 140mm 4 ksc PVC Pipes |
| 5580 | 50mm 6 ksc PVC Pipes |
| 5581 | 63mm 6 ksc PVC Pipes |
| 5582 | 75mm 6 ksc PVC Pipes |
| 5583 | 90mm 6 ksc PVC Pipes |
| 5584 | 110mm 6 ksc PVC Pipes |
| 5585 | 140mm 6 ksc PVC Pipes |
| 5586 | 160mm 6 ksc PVC Pipes |
| 5587 | 160mm HDPE PN6 Pipes |
| 5588 | 250mm HDPE PN6 Pipes |
| 5589 | 280mm HDPE PN6 Pipes |
| 5590 | 315mm HDPE PN6 Pipes |
| 5591 | 355mm HDPE PN6 Pipes |
| 5592 | 160mm HDPE PN8 Pipes |
| 5593 | 355mm HDPE PN8 Pipes |
| 5594 | PVC / HDPE Pipes - Major Burst |
| 5595 | 63mm 4 ksc PVC Pipes |
| 5596 | 75mm 4 ksc PVC Pipes |
| 5597 | 90mm 4 ksc PVC Pipes |
| 5598 | 110mm 4 ksc PVC Pipes |
| 5599 | 140mm 4 ksc PVC Pipes |
| 5600 | 50mm 6 ksc PVC Pipes |
| 5601 | 63mm 6 ksc PVC Pipes |
| 5602 | 75mm 6 ksc PVC Pipes |
| 5603 | 90mm 6 ksc PVC Pipes |
| 5604 | 110mm 6 ksc PVC Pipes |
| 5605 | 140mm 6 ksc PVC Pipes |
| 5606 | 160mm 6 ksc PVC Pipes |
| 5607 | 160mm HDPE PN6 Pipes |
| 5608 | 250mm HDPE PN6 Pipes |
| 5609 | 280mm HDPE PN6 Pipes |
| 5610 | 315mm HDPE PN6 Pipes |
| 5611 | 355mm HDPE PN6 Pipes |
| 5612 | 160mm HDPE PN8 Pipes |
| 5613 | 355mm HDPE PN8 Pipes |
| 5614 | GI Pipes - Above GL |
| 5615 | 125 mm GI pipe |
| 5616 | 100 mm GI pipe |
| 5617 | 80 mm GI pipe |
| 5618 | 65mm GI pipe |
| 5619 | 50 mm GI pipe |
| 5620 | MS Pipes - Above GL |
| 5621 | 300mm MS |
| 5622 | 350mm MS |
| 5623 | DI - Minor/ Circumferential Leak |
| 5624 | 200mm DI |
| 5625 | 250mm DI |
| 5626 | Supply and delivery of GM gate vaves as per IS BS5154 and related IS specification complete and as directed by the TWAD board officers. |
| 5627 | 50 mm GM Gate valve |
| 5628 | 65 mm GM Gate valve |
| 5629 | 80 mm GM Gate valve |
| 5630 | 50 mm GM NRV valve |
| 5631 | 65 mm GM NRV valve |
| 5632 | 80 mm GM NRV valve |
| 5633 | Repairing and reconditioning of Air Valve in pumping , booster and branch main |
| 5634 | 50mm DI Single Chamber Air release Valve |
| 5635 | 80mm DI Single Chamber Air release Valve |
| 5636 | 50mm CI Double Air Valve |
| 5637 | 40mm CI Double Air Valve |
| 5638 | 25mm CI Single Air Valve |
| 5639 | Supply and delivery of DI non return valve IS specification complete and as directed by the TWAD board officers. |
| 5640 | 50mm DI Non-Return Valve |
| 5641 | 65mm DI Non-Return Valve |
| 5642 | 80mm DI Non-Return Valve |
| 5643 | 100mm DI Non-Return Valve |
| 5644 | 250mm DI Non-Return Valve |
| 5645 | Supply and Delivery of MJ Collars 200mm |
| 5646 | REPAIR AND RENEWALS |
| 5647 | Rewinding of motors in pumping station in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 5648 | Repairing and reconditioning of 100 HP HSC Motor including all material, labour, etc |
| 5649 | Charges for removing the motor from bed after disconnection of power supply cable, Earthing line and Coupling arrangements by using contractor tools and materials. |
| 5650 | Transportation charges for conveying the motor from the Booster Station to Our work shop including loading and unloading charges. |
| 5651 | Labour Charges for removing the two end side cover with fan arrangements and the damaged driven end and non driven end bearings. |
| 5652 | Charges for removing the burnt wires from the rotor assembly and cleaning and checking the slots of rotor and labour charges for rewinding of Centrifugal Squirrel Cage Induction Motor after deducting the cost of old materials and including suppy and delivery of Class ‘F’ Insulation Super enameled Copper wire, required for rewinding and Fiber Glass wire, Fiber Glass Sleeves, Class ‘F’ insulation paper, Copper Socket and FG thread required for rewinding of Squirrel Cage Induction Motor |
| 5653 | Labour Charges for reconditioning the worn out shaft for driven end and non driven end bearing seating, knurling, bend checking, and etc., |
| 5654 | Supply and delivery of Driven End and Non Driven End bearings suitable for the required Induction Motor |
| 5655 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 5656 | Transportation charges for conveying the motor from work shop to Pumping Station |
| 5657 | Charges for reassembling the motor with bed and pump coupling, alignment checking connecting power supply cable, including required bolt and Nuts and testing trial running etc., |
| 5658 | Repairing and reconditioning of 100 HP HSC Pump including all material, labour, etc |
| 5659 | Charges for removing the motor from bed assembly after dismantling of Coupling arrangements and removing the pump assembly and including the provision of dummy flange arrangements by using contractor tools and materials. |
| 5660 | Transportation charges for conveying the Pump assembly from the Pumping Station to work shop including loading and unloading charges. |
| 5661 | Labour Charges for removing the impeller by using hydralic system, DE and NDE Bearings |
| 5662 | Labour Charges for reconditioning the worn out shaft including welding the shaft to suit the impeller and suit the driven end and non driven end bearing seating, knurling, bend checking and etc., |
| 5663 | Supply, delivery and fixing of Shaft sleeves in Gun metal including machining charges and making key ways after deducting the scrap materials |
| 5664 | Balancing of Rotor with impeller both dyanamically and Hydralically by using required dyanamic balancing machine |
| 5665 | Supply, delivery and fixing of Gunmetal seal rings for impeller neck including machining charges after deducting the scrap materials |
| 5666 | Supply and delivery of Driven End and Non Driven End bearings |
| 5667 | Labour Charges fixing the DE and NDE bearings correctly and neatly with required lubrications by contractors tools & Materials |
| 5668 | Transportation charges for conveying the Pump assembly from work shop to Pumping Station. |
| 5669 | Charges for reassembling the Pump with Motor by using pulley and alignment checking, including required bolt and Nuts and testing trial running etc., |
| 5670 | Repairing and reconditioning of 12.50 HP Submersible Pumpset including all material, labour, etc at Infiltration wells Head works |
| 5671 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5672 | Transporting the pumpset from Pump House to work shop. |
| 5673 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5674 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5675 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5676 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5677 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5678 | Repairing and reconditioning of 20 HP Submersible Pumpset including all material, labour, etc |
| 5679 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5680 | Transporting the pumpset from Pump House to work shop. |
| 5681 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5682 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5683 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5684 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5685 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5686 | Repairing and reconditioning of 4 HP and 3HP Submersible Pumpset including all material, labour, etc |
| 5687 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5688 | Transporting the pumpset from Pump House to work shop. |
| 5689 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5690 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5691 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5692 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5693 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5694 | Repairing and reconditioning of 1 HP Submersible Pumpset including all material, labour, etc |
| 5695 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5696 | Transporting the pumpset from Pump House to work shop. |
| 5697 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5698 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5699 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5700 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5701 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5702 | Repairing and reconditioning of 2 HP Submersible Pumpset including all material, labour, etc |
| 5703 | Removing the Submersible pumpset by using tripod set after disconnecting the power supply cable and delivery pipe line fittings |
| 5704 | Transporting the pumpset from Pump House to work shop. |
| 5705 | Rewinding the submersible motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5706 | Reconditioning the worn-out shaft and fittings, impeller and Gun Metal/ SS Bushes including cost of lath work & labour charges etc., |
| 5707 | Replacement of carbon type thrust bearing and pumpside Gun Metal Bush including cost of labour charges after deducting the cost of old material |
| 5708 | Transporting charges for Submersible pumpset from work shop to Pump House after attending repair works. |
| 5709 | Re-erection of pumpset in the Sump / Well by using tripod set and required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipeline arrangements testing to trial pumping. |
| 5710 | Repairing and reconditioning of 1HP Centrifugal Monoblock Pumpset including all material, labour, etc at Keelaveli to Pattiyadi |
| 5711 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5712 | Transporting the pumpset from the Pumping Station to work shop. |
| 5713 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5714 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5715 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5716 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5717 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5718 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5719 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5720 | Repairing and reconditioning of 3 HP Centrifugal Monoblock Pumpset including all material,labour,etc |
| 5721 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5722 | Transporting the pumpset from the Pumping Station to work shop. |
| 5723 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5724 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5725 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5726 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5727 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5728 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5729 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5730 | Repairing and reconditioning of 2 HP Centrifugal Pumpset including all material,labour,etc at Kallathur SP to kallathur |
| 5731 | Removing the Monblock Centrifugal Pumpset from the Bed assembly by using contractors tools and materials after disconnecting the power supply cable and delivery pipe line fittings with required dummy plate arrangements. |
| 5732 | Transporting the pumpset from the Pumping Station to work shop. |
| 5733 | Removing the Burnt winding materials from the stator slots and cleaning the stator and rotor assembly by using contractor tools and materials |
| 5734 | Reconditioning the worn-out shaft and fittings, impeller and Rope gland bush including cost of lath work & labour charges etc., |
| 5735 | Rewinding the Monblock Centrifugal Motor using best quality winding wire including cost of wire, Sleeve, other insulating and fibre class materials after deducting the cost of old materials. |
| 5736 | Replacement of driven end (No: XXXX) and Non driven end (No:XXXX) Bearings suitable for Monblock Centrifugal Motor including the cost of Bearing and labour charges after deducting the cost of old materials. |
| 5737 | Replacement of cooling fan at motor end and Terminal Board for suitable for Monblock Centrifugal Pumpset and labour charges after deducting the cost of old materials. |
| 5738 | Transporting charges for Monblock Centrifugal Pumpset from work shop to Pump House after attending repair works. |
| 5739 | Re-erection of pumpset in the Sump / Well by using required Rubber washer and Bolt & Nuts and connecting the power supply cable and delivery pipe line arrangements, testing and trial pumping. |
| 5740 | Attending the repair works in Soft Starter 100HP |
| 5741 | Labour Charges for removing the Burnt FCMA Coil, After Disconnecting the terminal connection and fixing the FCMA Coil after attending the rewinding work. |
| 5742 | Charges for Conveying the FCMA Coil from pumping Station to workshop and Workshop to pumping Station |
| 5743 | Labour Charges for Removal of unservicable contactor with all terminal connection suitable for the starter |
| 5744 | Labour Charges for Removal of Single Phase Preventer, Timer, CT Coil, Volt Meter, Ammeter, Selector Switch and PLA safety Relay suitable for the starter |
| 5745 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5746 | Charges for Removing the old wire from the FCMA Coil ,Cleaning, Rewinding of FCMA Coil and supply and delivery of Double Coated Enamel Copper Wire and all insulation materials after deducting old scrap materials etc., complete |
| 5747 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5748 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5749 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5750 | Replacement of Tin Copper Fibre Glass Wire for Main Control Wire suitable for the starter after deducting the old scrap value as directed by TWAD Board Officers. |
| 5751 | Replacement of Side mounting Add-on Auxillary Contact Block including the cost of material Suitable for the starter, as directed by TWAD Board Officers. |
| 5752 | Replacement of CT Coil with suitable Clamp Suitable for the starter as directed by TWAD Board Officers. |
| 5753 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5754 | Repairing and reconditioning of ATS Starter 12.50 HP |
| 5755 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete., and as directed by TWAD Board officers. |
| 5756 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 5757 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 5758 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 5759 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5760 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5761 | Repairing and reconditioning of ATS Starter 25 HP |
| 5762 | Labour Charges for removing the Burnt ATS Coil after draining the contaminated oil and cleaing the oil tank and fixing the ATS Coil after attending the rewinding work and filling the required oil in the oil tank etc., Complete,as directed by TWAD Board officers. |
| 5763 | Charges for Conveying the ATS Coil from pumping Station to workshop and Workshop to pumping Station |
| 5764 | Charges for Removing the old wire from the ATS Coil , Cleaning, Rewinding of ATS Coil by using double Coated Enamel Copper Wire and all insulation materials including the cost of materials after deducting old scrap materials etc., complete |
| 5765 | Labour Charges for Removal of unservicable / burnt contactor with terminal connection Single Phase Preventer, Timer, OLR, CT Coil and PLA safety Relay suitable for the starter |
| 5766 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5767 | Supply and Delivery of PLA Safety Relay suitable for the starter |
| 5768 | Replacement of On delay / OFF Delay Timer including the cost of material suitable for the starter as directed by TWAD Board officers. |
| 5769 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5770 | Repairing and reconditioning of DOL Starter 1 HP |
| 5771 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5772 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5773 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5774 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5775 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5776 | Repairing and reconditioning of DOL Starter 2 HP |
| 5777 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5778 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5779 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5780 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5781 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5782 | Repairing and reconditioning of DOL Starter 3 HP |
| 5783 | Labour Charges for Removal and Re-fixing of unserviceable or burnt Single phase Preventer, MCB, Over load Relay, terminal block , Contactor and capacitor for the starter |
| 5784 | Replacement of required capacity moving kit of Contactor, and No Volt Coil suitable for the starter including the cost of materials etc., complete |
| 5785 | Charges for Replacement of burnt control circuit wire, ON / OFF Switch and required Main Wire including required cable crimping work in the starter including the cost of materials etc., complete |
| 5786 | Replacement of Terminal block Suitable for the starter as directed by TWAD Board Officers. |
| 5787 | Replacement of power supply Phase indicator, ON / OFF Indicator suitable for the starter. |
| 5788 | Replacement of Electrical items |
| 5789 | Volt meter SR 96 600 V-AC |
| 5790 | Ammeter SR 96 5D/5A C.T.operated-AC |
| 5791 | LED Outdoor fittings a) 30 W LED street light fittings |
| 5792 | Supply, delivery and fixing of 200 AMPS porcelain Fuse unit (500V) with fuse |
| 5793 | Supply, delivery and fixing of 100 AMPS porcelain Fuse unit (500V) with fuse wire in the existing place inside the pump room for sump |
| 5794 | Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/ 440V 50 HZ conforming to ISS:2834 with ISI markingTWAD SR 2022-23/P.205 |
| 5795 | Sump Cleaning |
| 5796 | Cleaning of all storage points like sumps, stand posts of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, dewatering, desilting using rquired machineries , materials , labour, all incidental chargs , application of bleaching powder/ solution etc complete and as directed by TWAD Board officers |
| 5797 | 2.2 LL capacity of sump @ Head works |
| 5798 | 4.00 LL capacity of sump @ Vanathirayanpattiam |
| 5799 | 2.00 LL capacity of sump @ Kazhuvanthondi Booster |
| 5800 | 0.3 LL capacity of sump @ Pilichikuli, Cholakuruchi, Keelaveli |
| 5801 | 1.00 LL capacity of Stand Post @ Kallathur, Vankudy |
| 5802 | 1.50 LL capacity of Stand Post @ Periayavalaiyam, Radhapuram |
| 5803 | Supply and delivery of electrode assembly suitable for water disinfection equipment using silver ionization process using pure silver metal electrode and fixed on PVC/Nylon sheets and nuts with electrical leads for the following capacities. The supply should be with the quality test certificate from approved organisations. (For 2 time eloctroedes replacement per year) |
| 5804 | 2,00,000 LPH |
| 5805 | 10,000 LPH |
| 5806 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. Please Enable Macros to View BoQ information |
| 5807 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of disinfectents such as bleaching powder/ Common Salt as applicable. The supply should be with the quality test certificate from approved organisations. Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail