| 1 | Cutting BT Road Surface etc., complete |
| 2 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete (Upto 2.00m) |
| 3 | Removing the burst RCC pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the departmental Officers. 3 times of ordinary rate is allowed since the works are done in odd hours400 mm dia Pipe (upto 2m) |
| 4 | Dewatering using 3hp to 70hp diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete.Hire charges for Diesel Pump set For 3 HP |
| 5 | Supplying, Laying and Joining of CI Pipe with socket and spigot ends for LA Class as per IS 1536/2001 etc complete as directed by Engineer-in-charge400mm CI LA Class Pipe - Depth upto 2.00m |
| 6 | Refilling the trenches with suitable excavated earth available along the alignment after the pipes & specials are laid, jointed & tested in layers & watering, ramming & consolidation directed by the Engineer-in-Charge. |
| 7 | Disposal of surplus earth including loading and conveyance within a distance of 5 km (basic cost of earth is zero) including loading charges and Conveyance Charges of 5 kms distance. |
| 8 | Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by the Departmental Engineer. |
| 9 | Hire charges for portable Genset 1.00 KVA with 2 Nos. of 150W flood light including all incidental charges, transportation, crew charges and fuel charges etc., complete. |
| 10 | Replacement of Underground Utilities (PVC Pipe) damaged during earthwork excavation for pipe laying works including cost of additional earthwork excavation in all soil strata, including BT/CC road cutting, removal of slushy soil and replacing the pipeline with sound pipe, including supply and delivery of PVC pipes, couplers, jointing materials and required specials, cutting, conveying , laying, jointing and cost of refilling for the additional earthwork etc complete and as directed by the departmental officers.140mm PVC 6Ksc Pipe |
| 11 | Restoring the tar road surface by spreading Sand filling, filling gravel and WMM over a layer of 30 cm thick gravel and providing premix carpet with seal coat type 'A' including cost of all materials etc. complete 10m2 |
| 12 | Supply and delivery of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16400mm Gate Valve |
| 13 | Supply of C.I. Double Air Valve As Per ISI 14845/2000 and with 5 years warranty etc complete 100mm Air Valve |
| 14 | Supplying of CI Specials with socket and spigot ends for as per IS 1538/1993 etc complete as directed by Engineer-in-charge |
| 15 | Jointing C.I/ D.I double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete including charges for special tools and plants such as air compressor and helmets and sheet piles. etc (including cost of jointing materials) 400mm dia pipe |
| 16 | 80mm dia pipe |
| 17 | Construction of Valve chambers of following sizes with earthwork excavation for foundation with Dust Filling 15cm thick and Plain cement concrete bed in C.M. 1:4:8 using 40mm HBG jelly 10mm thick for foundation, 23cm thick brick wall work in C.M.1:5 for chambers, Inner and Outer Plastering with C.M. 1:3 12mm thick, benching, channelling, MS Grill frame covering in C.M. 1:2:4 mix using 20mm blue granite jelly including necessary reinforcement, etc., complete |
| 18 | ADD GST 18% Please Enable Macros to View BoQ information |