| 1 | CONSTRUCTION OF BUS SHELDER AT MUTHUPETTAI MAIN ROAD IN THALAYAMANGALAM PANCHAYAT |
| 2 | Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. Refilling the sides of foundation with excavated earth other than sand in layers of well rammed and compacted and depositing the surplus earth in places shown by the departmental officers with an initial lead of 10m and initial lift of 2m and clearing and leveling the site etc. complete complying with standard specification. |
| 3 | Supplying and filling in foundations and basement with filling M sand in layers not exceeding 15 cm. thick, well watered ,rammed and consolidated etc. complete complying with standard specifications. |
| 4 | Plain Cement Concrete: 1:4:8 - One part Cement:Four part Sand:Eight part hard broken stone jelly using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick,well rammed,consolidated and curing etc.complete complying with standar specification. |
| 5 | Providing and laying in position, Standardised Concrete mix M-25 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement concrete 350kg/m3 and maximum water cement ratio of 0.5, including admixture (plasticiser / super plasticiser) in recommened proportion as per IS :9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0cu.m) 7730kg of 20mm machine crushed stone jelly and with about (3.3cu.m) 5156 kg of 10-12mm machine crushed stone jelly and wiht about (4.79cu.m) 7670 kg of M.Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fanc clams in the RCC floor/ roof slabs wherever necessary without claiming extra, etc, complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards . (No separate payment will be made by the Department for hte excess usage of materials). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Providing and laying cement concrete 1:2:4 (1 cement : 1 coarse sand : 2 graded brick aggregate 20 mm nominal size) for sunken floor filling excluding the cost of centring and shuttering upto floor five level. |
| 8 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) . |
| 9 | Providing and Laying of Interlocking Concrete (Surface Textured) Block Pavements having thickness 60mm and compacted over a thin bedding sand layer of 25 mm thickness and joints shall be filled by fine sand of specified grading as per table 1500.6 of Specification of Rural roads-2014 and Technical specification clause 1504. |
| 10 | steel reinforcement for R.C.C work ready to use cut and bend rebars of apporved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level , thermo-mechanically treated bars of grade Fe-550D or more |
| 11 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 12 | Providing corrugated G.S. sheet Cladding including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers including cutting to size and shape wherever required. |
| 13 | Providing corrugated G.S. sheet Cladding including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers including cutting to size and shape wherever required. |
| 14 | Providing Ridge sheet |
| 15 | Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu.conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for open PVC light/ fan point (SD No.22) |
| 16 | Supply and fixing of 4'-18W LED tube with fitting inclusive of all charges |
| 17 | Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu. conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for open PVC plug point (SD No.37) 5 pin plug point |
| 18 | Supply and fixing of TNEB meter Board suitable for 32A Single Phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. (SD No. 125) |
| 19 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes, Bends, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \\"U\\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 20 | Providing Granit CHAIR arrangements with fixing. The cost shall include all labour and materials and as directed by the departmental officers. |
| 21 | Provision for EB post shifting charges |
| 22 | Provision for Name board charges |
| 23 | Provision for Photo charges |
| 24 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \\"BB\\" for all works in this package} gst lwf contingec 3751378.51 675248.1318 37513.0 908.0 35000.0 4500047.6418 0.0 0.0 0.0 0.0 3751378.51 4500047.6418 0.0 4500047.6418 -748669.131800001 Please Enable Macros to View BoQ information |