| 1 | Cutting in earth work in all kinds of soil such as pick work, jumper work, blasting work and chiselling work etc. and disposal of excavated earth upto a lead of 20 metres as directed within all leads and lifts. |
| 2 | Excavation in foundation, trenches,etc. in earth work in all kinds of soil such as pick work, jumper work,blasting work, hard blasting and chiselling etc. lift upto 50 mtrs. stacking the excavated soil not more than 3 mtrs.clear from the edge of excavation and then returning the stacked soil in 15cm.layers when required into plinths sides of foundations etc.then consolidating each disposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads and lifts of 20 mtrs.complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 3 | Excavation in earth work and disposal of all excavated earth upto a lead of 20 metres and lift upto 1.50 metres disposed earth to be levelled and neatly dressed.complete in all respect and to the entire satisfaction of the Engineer-in-charge.in pick & jumper work 50% each. |
| 4 | Excavation in drains and channels etc. in earth work for pipes upto all depth in all classification of earth work such as pick work, jumper work, saturated soil i/c balling or pumping out water , blasting soft /hard rock or chiseling soft/ hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming and dressing of sides, levelling of beds to correct grade including shoring /struting, planking, timbering and dewatering wherever required stacking the useable /unusable material/soil seperately and after laying,jointing and testing of pipes ,returning the useable soil in treches in 15 cm layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion for traffic, night signals, fixing caution boards,crossing over trenches for access to houses, fencing etc. complete in all respect whithin all leads and lifts as per direction of the Engineer-in-charge. |
| 5 | Providing and laying cement concrete 1:3:6 (1cement: 3sand: 6graded stone agg. 40mm nominal size) and curing complete excluding cost of form work i/c all leads and lifts :-a) Foundation and plinth within all leads and lifts. |
| 6 | Prov. and laying cement concrete 1:4:8 (1cement:4sand:8graded stone agg. 40mm nominal size) and curing complete excluding cost of form work i/c all leads and lifts :-a) Foundation and plinth.within all leads and lifts. |
| 7 | Providing and laying cement concrete 1:6:12 (1cement:6sand:12graded stone agg.40mm nominal size) and curing complete excluding cost of centring and shuttering in: a) Foundation and plinth.within all leads and lifts. |
| 8 | Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone agg. 40mm nominal size)with 15% plum concrete and curing complete excluding cost of form work in retaining wall/breast wall, the size of plums shall usually be 150mm to 300mm.as per HPPWD specifications within all leads and as per the direction of the Engineer-in-charge. |
| 9 | Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone agg. 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and as per the direction of the Engineer-in-charge. |
| 10 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden, battens, and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work complete in all respect in all leads and lifts and to the entire satisfaction of the Engineer-in-charge. |
| 11 | Foundation footings bases of column and mass concrete. |
| 12 | Flat surfaces such as soffits of suspended floors,roofs, landings, and the like:-Floors etc. upto 200mm in thickness. |
| 13 | Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttresses, plinth and string courses and the like. |
| 14 | Edges of slabs and breaks in Floor and walls :- Under 20cm wide. |
| 15 | Column Pillars, posts and struts square, rectangular or polygonal in plan. |
| 16 | Beams, cantilevers, girders and lintels:- Sides and soffits of beam, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 mtrs. in depth in all height from floor. |
| 17 | Sloping or battering surfaces including folded plates: Where inclination to horizontal plane exceeds 30 degrees. |
| 18 | Stair cases with sloping or stepped soffits excluding landing. |
| 19 | Providing form work of ordinary timber, plankings so as to give a fair finish including centring, shuttering, strutting , strutting and propping etc. height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work in:- |
| 20 | Arches upto 6 mtrs. span. |
| 21 | Providing and laying cement concrete work 1:1:2 (M25) (1cement:1 sand:2 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement in reinforced concrete work i/c all leads and lifts complete in all respect.:-Foundation, footing, bases of columns and mass concrete. |
| 22 | Walls (any thickness) but not less than 0.1 m thickness) including attached pillasters,buttresses, plinth and string courses etc.from top of foundation level upto floor two level. |
| 23 | Providing and laying cement concrete work 1:2:4(1cement:2sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work i/c all leads and lifts complete in all respect. :- |
| 24 | a)Foundation footings, bases of column and the like and mass concrete. |
| 25 | b) Walls (any thickness) but not less than 0.10 m thickness) attached pillasters, buttresses,plinth and string courses etc. from top of foundation level upto floor two level. |
| 26 | d) Column, pillars posts and struts upto floor two level. |
| 27 | c)Suspended floors, roofs, landings,shelves and their supports balconies, beams, girders, bressumers and cantilevers upto floor two level. |
| 28 | e)Stair cases (except spiral stair cases) excluding landing but including preparing of the surface and finishing of nosing upto floor two level. |
| 29 | Arches upto floor two level. |
| 30 | Boulder filling behind retaining walls. |
| 31 | Providing Mild steel/Tor steel reinforcement for RCC work including bending, binding and placing in position complete upto floor two level i/c all leads and lifts complete in all respect. :- a) Tor steel. |
| 32 | Providing in RCC work smooth finishing of the exposed surfaces with cement mortar 1:3 (1cement:3sand) complete in all respect. |
| 33 | Supplying and fixing cast iron cover with frame for man hole of size 500mm internal dia (For frames of 500mm internal dia meters C.I.cover medium duty the weight of cover to be not less than 58 kg).including all leads lifts and carriage of material at site complete in all respect. |
| 34 | Prov. 200mm wide cast iron rungs with chequered or ribbed non slip surface including fixing in manholes with 200mmx 200mmx 100mm cement concrete 1:3:6 (1cement:3sand:6graded stone agg. 20mm nominal size).complete in all respect i/c all leads and lifts. |
| 35 | Laying and jointing in trenches,galvanised mild steel tubes (Light grade)i/c Providing and fixing of tube fittings such as Tee, elbow, union & nipple.(earth work in trenches to be measured and paid for separately)i/c all leads and lifts complete in all respect .Labour rate only. |
| 36 | 15mm dia nominal bore. |
| 37 | 20mm dia nominal bore. |
| 38 | 25mm dia nominal bore. |
| 39 | 32mm dia nominal bore. |
| 40 | 40mm dia nominal bore. |
| 41 | 65mm dia nominal bore. |
| 42 | 80mm dia nominal bore. |
| 43 | 100mm dia nominal bore. |
| 44 | 125mm dia nominal bore. |
| 45 | Prov. and fixing brass full way valve with wheel of superior quality including all leads and lifts In :- |
| 46 | 15mm dia nominal bore. |
| 47 | 20mm dia nominal bore. |
| 48 | 25mm dia nominal bore. |
| 49 | 32mm dia nominal bore. |
| 50 | 40mm dia nominal bore. |
| 51 | 65mm dia nominal bore. |
| 52 | Providing and fixing double flanged cast Iron sluice valve of Leader/Kirloskar/ BHEL/Kilburn /GLED/Kartar /Fouress make and 100mm/125mm dia having bye pass arrangement on the delivery line of the pump and capable of with normal seat pressure as per IS-14846 with upto date amendments |
| 53 | 125mm dia PN.1.0 |
| 54 | 100mm dia PN.1.6 |
| 55 | Steel work welded in built up sections, trusses and framed work including cutting hoisting, fixing in position and applying a priming coat of red lead paint i/c all leads and lifts complete in all respect. |
| 56 | In gratings framed guard bars, ladders, railings, brackets and similar works. |
| 57 | In beams, joists, channels, angles, tees, flats with connection plates or angle cleets as in main and cross beams, hip and jack rafters, purlins connected to common rafters and the like. |
| 58 | In trusses and trussed purlins in buildings.(ISMC).complete in all leads and lifts. |
| 59 | Brick masonry of 2nd class in foundation and plinth in cement mortar 1:6 (1 cement :6 sand) including all leads and lifts complete in all respect. |
| 60 | Prov. and placing in horizontal layer filtering media duly graded ,screened, washed and cleaned as specified by the Engineer-in-charge. i/c all leads and lifts. |
| 61 | I. Top layer:- Fine sand (Eff.size 0.20mm to 0.40mm and uniformity-co- efficient 2.00 to 3.00). screened,cleaned,washed and graded from approved source. |
| 62 | II. Second layer:- Coarse sand 3mm to 6mm. screened,cleaned,washed and graded from approved source. |
| 63 | III.Third layer:- Bajri 6mm to 20mm.screened,cleaned,washed and graded from approved source. |
| 64 | IV. Fourth layer:- Bajri 20mm to 25mm.screened,cleaned,washed and graded from approved source. |
| 65 | V. Bottom layer:- Broken stone 50mm to 75mm size.screened,cleaned,washed and graded from approved source. |
| 66 | Half brick masonry in common burnt clay building bricks in cement mortar 1:4(1cement:4sand) second class bricks including all leads and lifts complete in all respect. |
| 67 | Providing and fixing pressed steel door frames manufactured from commercial, mild steel sheet of 1.25mm thickness including hinge jamp, lock jamp beed and if required angle threshold of mild steel angle of section 50x25 mm or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lungs with split and tails to each jamp including steel butt hinges 2.5mm thick with mortor guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pretreatment of the surface i/c all leads and lifts and as per direction of Engineer-in-charge. |
| 68 | Profile \\"A\\" |
| 69 | Profile \\"B\\" |
| 70 | Profile \\"C\\" |
| 71 | Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows including black enamelled iron butt hinges with necessary screws:-including all leads and lifts in:-a) 40mm thick deodar wood 2nd class. |
| 72 | Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of IS gauge designation 85 G with wire of dia 0.56 mm for door windows and clear storey windows i/c bright finished black enemelled iron hinges with necessary screwes. a)40mm thick 2nd class Deodar Wood. |
| 73 | 15mm cement plaster in single coat on fair side on brick/concrete/stone walls for interior plastering upto floor two level including arrises, internal rounding angles, chamfers and or rounded angles not exceeding 80mm in girth and finished even and smooth:- |
| 74 | Cement mortor 1:6. (1cement: 6sand). i/c all leads and lifts. |
| 75 | 20mm cement plaster in single coats,on rough side of bricks/stone walls for interior plastering upto floor two level including arrises internal rounded angles, chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth:-a)In cement mortar 1:6 (1cement:6sand ) including all leads and lifts. |
| 76 | 6mm cement plaster to ceiling including all leads and lifts complete:-In Cement mortar 1:3(1cement:3sand). |
| 77 | White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt, dust , mortar dirt and other foreign matter as per the direction of Engineer-in-charge including all leads and lifts. |
| 78 | Distempering (two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and i/c a priming coat with distempering primer of approved brand and manufacturem after thoroughly brushing the surface free from mortar dropping and other foreign matter and also i/c preparing the surface even and sand papered smooth.Priming coat with distemper primer with in all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 79 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove dirt, loose or softened paint including all leads and lifts. |
| 80 | Precast terrazzo tiles hydraulic compressed 20mm thick (with marble chips of specified shade and specified sizes) laid in floors, treads of steps and landings on a bed of 25 mm average thickness of cement plaster 1:6 (cement:6sand) jointing with neat cement slurry mixed with pigment to match the shade of tiles (wherever required) including rubbing and polishing complete with tiles of grey shade i/c all leads and lifts complete in all respect. |
| 81 | In skirting and riser of steps and dado not exceeding 30cm in height on 10mm thick cement plaster 1:3(1cement:3sand) and jointed with slurry mixed with pigment to match the shade of tiles i/c rubbing and polishing complete with tile of grey shade. |
| 82 | Applying priming coat over new wood and other wood based surfaces after and including preparing the surface by thoroughly cleaning oil grease dirt and other foreign matter sand papering and knotting including all leads and lifts.With ready made paint brushing wood primer pink. |
| 83 | Painting two coats (excluding priming coat) on new wood and wood based surfaces, with enamel paint brushing to give an even shade including cleaning of all dirt dust and other foreign matter,sand papering and stopping:-including all leads and lifts.With enamel paint other than white. |
| 84 | 1.80 mtrs. High fencing with steel post of built up section 2.50 metre centre to centre with nine horizontal lines and two diagonals of galvanised steel barbed wire (IS: 278-1962 type.I) weighing 9.38 kg/ per 100 metre (minimum)strained and fixed to posts with G.I staples,M.S.wires or steel pins etc. including coal tarring of ballies complete) cost of post, struts and straining bolts shall be paid for separately). |
| 85 | Painting two coats (excluding priming coat) on new steel and other metal surfaces with readymixed paint brushing to give an even shade including cleaning the surface all dirt, dust and other foreign matter i/c all leads and lifts and as per direction of Engineer-in-charge:-With readymixed paint other than white. |
| 86 | Providing and fixing M.S. grills of required pattern in wooden frames of windows etc.with M.S.flats square or round bars with round headed bolts and nuts or by screws complete in all respect including all leads and lifts as per the direction of the Engineer-in-charge. Plain grills. |
| 87 | Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding material moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts as directed by the Engineer-in-Charge. |
| 88 | Providing and fixing of M.S.sliding door bolts brigtht finished or/and black enamelled with bolts,nuts and screws etc. complete. |
| 89 | 250x 16mm. |
| 90 | Providing and fixing M.S. Tower bolts (barrel type) anodized transparent or dyed to required shade and colour with screws etc. complete. |
| 91 | 200x10mm. |
| 92 | 100x10mm. |
| 93 | Providing and fixing M.S. handles with necessary screws etc. complete i/c all leads and lifts and as per direction of Engineer-in-charge. |
| 94 | 125mm. |
| 95 | 100mm. |
| 96 | Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm.1:3:6 (1cement: 3sand: 6graded stone agg. 20mm nominal size).complete in all respect as per the direction of the Engineer-in-charge including all leads and lifts. |
| 97 | Providing plinth protection 50mm thick in cement concrete 1:3:6(1 cement :3sand:6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth including all leads and lifts. |
| 98 | Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3(1cement:3sand) over a 12mm layer of cement mortar 1:3(1cement:3sand) and finished neatly withhin all leads and lifts as direction by the Engineer-in-charge. |
| 99 | Providing and fixing PVC \\"P\\" or \\"S\\" trap for water closet (squatting pan) ISI marked including jointing the trap with the pan and PVC pipe with approved adhesive etc. complete in all respect.110mm dia. |
| 100 | Providing and fixing in cement mortar 1:3(1cement:3sand), a pair of Vitreous China foot rest 250x130x 30mm complete in all respect i/c all leads and lifts. |
| 101 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete.110mm dia. |
| 102 | Providing and fixing PVC door bend with oval access door, insertion rubber washer 3mm thick bolts and nuts ISI marked complete including fixing with approved adhesive etc. complete. 110mm dia. |
| 103 | Providing and fixing PVC plain collars ISI marked including fixing with approved adhesive etc.complete. 110mm dia. |
| 104 | Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. complete.110mm dia. |
| 105 | Providing and fixing PVC clamps ISI marked of approved design with steel screws and rawal plugs etc.complete.110mm dia. |
| 106 | Providing and fixing PTMT coloured/white high density polyethylene/poly propylene 10 litres capacity (full flush) European standard control low level flushing cistern with fittings with a pair of brackets with fittings such as lead valve, syphon, 15mm nominal size PVC ball valve with polythene float, with push button, couplings for connections with inlet, outlet and overflow pipe, 40mm dia C.P.flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for seprately). |
| 107 | Providing, placing on terrace (at all floor levels) and fixing PVC water storage tank of ISI :12701 marked, G.I. inlet and outlet connection, 15mm nominal bore ball valve and mosquito proof PVC cover with locking arrangement including hoisting upto all heights above ground level.within all leads and lifts.500 litres net capacity tank |
| 108 | Providing and fixing vitreous China wash, down water closet(Eruropen type W.C.pan)with integral \\"P\\" or \\"S\\" trap including jointing the trap with soil pipe in cement mortar 1:1(1cement:1sand) (seat and cover to be measured and paid for separately):- Ordinary closet. |
| 109 | Wiring for light point/fan point/exhaust fan point/call bell point wire 1.5 sqmm.FRLS PVC.insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible) insulated copper conductor cable in surface/recessed.Medium class with piano type switches, phenolic laminated sheet, suitable size MS. box PVC conduit and earthing the light point with 1.5sq.mm.HRFRLS/PVC insulated single core copper conductor cable as required complete in all respect. Group C. Light point. |
| 110 | Wiring for light/power plug with 2x1.5sq.mm.FRLS PVC insulated heat resistant (HRFR) and low smoke single core (flexible) insulated copper conductor cable in surface/recessed Medium class PVC conduit along with 1No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.a) 2x1.5 sq.mm. |
| 111 | Wiring for power plug with 2x4 sq.mm FRLS PVC insulated, heat resistant flame retardant (HRFR) and low smoke single core (flexible)copper conductor cable in surface/recessed Medium class PVC conduit along with 1 No.4 sq.mm.HRFRLS/PVC insulated single core copper conductor cable for loop earthing as required. |
| 112 | Wiring for circuit/submain with following size FRLS PVC insulated heat resistant flame retardant (HRFR)and low smoke single core (flexible)copper conductor cable in surface/recessed medium class PVC conduit along with 1No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 113 | 2x1.5 sq.mm. + 1x1.5 sq.mm.earth wire. |
| 114 | 2x4.0 sq.mm. + 1x 4 sq.mm.earth wire. |
| 115 | 2x10 sq.mm. + 1x 6 sq.mm.earth wire. |
| 116 | Supplying and fixng LED tube light 20 watt with holder and lamp i/c all necessary fitting complete in all respect. |
| 117 | Providing and fixing LED lamp/bulb 15 watt i/c all necessary fitting complete in all respect. |
| 118 | Providing and fixing 40 watt street light fixture complete with LED lamp bend and suitable copper wire etc.of reputed make complete in all respect. |
| 119 | Supplying and fixing bakelite batten/angle holder including connections etc. as required. |
| 120 | Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess complete with tinned copper bus bar wire set, neutral bus bar, earth bar, din bar (but without MCB/ RCCB/Isolator) detachable gland plate, interconnections, phosphatized and powder painted,including earthing etc. as required : a) Double door 8 way. |
| 121 | Supplying and erection of 6 amps to 32 amps. Rating 10 KVA breaking capacity 240/415 volts.\\"C\\" curves miniature circuit breaker suitable for indicative load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. Single Pole. Cat.A. |
| 122 | Supplying and fixing of of 63 amps. Rating, double pole (single phase & neutral), 240 volts, residual current circuit breakder (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc.as required. |
| 123 | Supplying and fixing following rating piano-type modular switch/socket on the existing switch box/ cover including connections etc. as required. |
| 124 | S.P.5/6 Amps.one way switch piano type. ISI marked |
| 125 | S.P.15/16 Amps.one way switch piano type. ISI marked |
| 126 | 3 pin 5/6 amps. Socket outlet,piano type. ISI marked |
| 127 | 6 pin 15/16 Amps.socket outlet, piano type. ISI marked |
| 128 | Earthing with copper earth platle 600mmx 600mmx 3mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtrs. length etc. (but with charcoal or coke and salt) complete as required. |
| 129 | Supplying and laying 25mm x 5mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required (jointing shall be done by over lapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm). |
| 130 | RISING MAIN:- |
| 131 | Providing, laying,welding, testing and commissioning at site in trenches to be bevelled edge pipe conforming to IS/ISO:3183-2007 (Latest with up to date amendments) having minimum wall thickness as specified below & capable of withstanding required test pressure as prescribed in IS/ISO code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be levelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest applicable and with uptodate ammendments (leak proof) in three layers at site of work with welded rods of Advani/oeriliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces,tee bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-In-Charge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API L 320 or X-46 grade. The laying shall confirm to BIS 5822-970 or latest with upto date ammendments to the entire satisfaction of Engineer-In-Charge. (Earth work & cost of MS Flanges after 100meter length shall be measured & paid for seperately.) including all leads, lifts and carriage of material at site and as per direction and to the entire satisfaction of the Engineer-In-Charge. |
| 132 | R.D. 0-1100 100mm dia. API L-320 or X-46 with 4.80mm wall thickness. |
| 133 | Laying and jointing in trenches galvanised mild steel tube (Heavy grade) of following diameters conforming to IS-1239 as specified below jointed with butt welding (leak proof) in three layers at site of work with welding rods of Advani/oeriliken make/ISI marked (welding rods 3mm to 4mm) according to relevant BIS code 816-1969 including all short pieces bends,tee and other specials etc. made from parent tubes as applicable for the particular reach and of approved specifications as per site conditions including flushing, cleaning and hydraulic testing complete to the best satisfaction of the Engineer-in-charge. The laying of pipes should conform to BIS code 5822-1970 within all leads and lifts complete in all respect. |
| 134 | R.D. 1100-1800 .G.I.1239 100mm dia Heavy grade. |
| 135 | Providing welding (conforming to IS code 3138-1986 ) and fixing of M.S.plate flanges of various dia (100mm nominal bore) of following flange tables conforming to IS-6392-1972 (latest with upto date ammendment) to API/GMS pipe after every 100 mtrs. pipe or as per site requirement including cutting of pipes wherever required, welding in three layers (two layers out side and one layer inner side) (leak proof) conforming to specifications as per prescribed in relevent IS code i.e. IS: 816-1969 or latest as applicable with upto date ammendments with nuts, bolts and washers & specials etc. conforming to IS: 1963 or latest with upto date ammendments including packing sheet i.e. asbestos fiber sheet minimum 3mm thick and painting with anticorrosive paints complete in all respect including all leads and lifts and as per entire satisfaction of Engineer-in-charge. |
| 136 | Table.34 R.D.0 to 700 |
| 137 | Table.28 R.D.700 to 1100 |
| 138 | Table.17.R.D.1100 to 1500 |
| 139 | Table.11.R.D.1500 to 1800 |
| 140 | Providing and fixing double flanged swing cast steel sluice valve of Kirloskar/Leader/BHEL/Kilburn/ GLED/ Kartar/ Fouress make make of 100mm dia having by pass arrangement on the delivery line of pump & capable of with standing the normal seat pressure as per IS-5312-1984 P-I with upto date ammendments Class ASA-300 as per the direction of the Engineer-in-charge complete in all respect i/c all leads and lifts. 100mm dia ASA-300. |
| 141 | PUMPING MACHINERY: Please Enable Macros to View BoQ information |
| 142 | PUMPING MACHINERY: Please Enable Macros to View BoQ information |