| 1 | Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPMagainst head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pumpbowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase230 V+/- 10 %,50 HZ +/-5 % 20x100 Duty x lpm |
| 2 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amendedthereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole MagneticContactor with under Voltage protection, Indication lamp, starting capacitor, running capacitorand On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVCinsulated cable, powder coated vermin proof box including the capacitor (the cost of capacitoris to be taken separately). |
| 3 | Supply and delivery of 32mm Dia u PVC Coulum pipe for Submersible Pipe Heavy type with ISI Mark each pipe 3m Length with Coupler Joint including cost of Pipe and conveyance charges etc complete.(TWAD 2022-23 PAGENO.24) |
| 4 | Supply and delivery of 2.5.0 Sq.mm PVC insulated and sheathed 3 core flat type copper cable conforming to is 694/1990 including cost and conveyance charges etc complete TWAD 2022-23- Pageno.120 |
| 5 | Supplying, laying and jointing PVC Pipes, G.I. Pipes of approved quality and best variety of \\"B\\" class pipe of the following dia including labour fixing G.I. Specials, PVC Specials including charges for cutting and threading of pipes, cost of such specials with necessary teak wood plugs, clamps, screws, thread balls, shellac, etc., etc., complete 32mm dia coulmn pipe adaptor |
| 6 | 32mm GI Pipe B Class |
| 7 | 32mm GI Elbow |
| 8 | 32mm GI Union |
| 9 | 32mm MS Clamp set |
| 10 | 40mm GM Non Return Valve |
| 11 | 32mm GI Hex Nipple |
| 12 | 32mm GI Coupling |
| 13 | 25mm Dia PVC Pipe |
| 14 | 25mm dia PVC Bend |
| 15 | 25mm dia PVC Tee |
| 16 | 25mm dia PVC Coupler |
| 17 | 25mm dia PVC Elbow |
| 18 | 20mm dia GI Pipe |
| 19 | 20mm dia GI Bend |
| 20 | 32mm x 25mm GI dia Reducer |
| 21 | PVC Screw down tap20mm |
| 22 | Gun metal gate valve |
| 23 | 25mm x 20 mm dia GI Reducer |
| 24 | 32mm x 25mm dia PVC Reducer |
| 25 | Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2\\" x 1-1/2\\" x 1/4\\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\\" x 1/4\\" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete (SD 130) |
| 26 | Supply and delivery and fixing of HDPE tank 1000 Litre as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., |
| 27 | Brick work in CM 1:5 (one cement five sand) using country bricks including cost and conveyance of all charges etc., complete as per standard specifications. |
| 28 | Plastering with Cement mortar 1:5 (One cement Five sand) mix using 12mm thick including cost and conveyance of all charges etc., complete as per standard specifications. |
| 29 | Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification. |
| 30 | Labour charges for the removal of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth valves erection clamps, pressure gauges uptp the exterior wall of pump room and erection of panel board consisting of TPICN swithces starter, voltmetre, ammetre, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10days. |
| 31 | Supply and Run of 2 of 10 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade on 7/20 GI wire for service connection mains Providing and laying Bituminous Concrete to 30/40mm thick using 0.13 cu.m of 19.00-9.50mm, 0.17 cu.m of 9.50-2.36mm and 0.26 cu.m of 2.36 and below with 47.28kgs of VG30 bitumen and 3.02Kgs of Waste Plastic for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5 Please Enable Macros to View BoQ information |