| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Earthwork excavation in all soil and sub soils except hard rock requiring blasting with initial lead and lift including re filling the sides of foundation in layer of 15 cm thick watering, ramming, depositing the surplus earth in the premises as directed by the departmental officers, etc., complete complying with standard specification. |
| 3 | Cement concrete in 1:4:8 (one cement, four sand and eight aggregate) mix using 40mm ISS hard broken granite metal for foundation including dewatering where ever necessary including cost and conveyance of all materials to work site and labour charges etc., |
| 4 | Supply and erection of steel centering, shuttering for soffits and sides including necessary support strutting for all RCC works using MS sheets of suitable size of BG 10 stiffened with MS angle of size 25x25x3mm for boarding laid over Silver Oak joists of size 10cmx6.5cm space at 10cm c/cand supported by Casurino Prop 10cm-13cm spaced at 75cm c/c etc., complete and as directed by Departmental Officers. |
| 5 | G.Beam |
| 6 | Column Surface |
| 7 | Plain Surface |
| 8 | Supply and fabrication of steel using TMT rods for all Reinforced cement concrete works including cost and conveyance of all materials and all labour charges for cutting, bending and placing the rod in position and tying up the rods with binding wire and other incidental charges etc., complete. as per standard specification SS 86 & 86A V,VI, VII (S6) 7,3 |
| 9 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - |
| 10 | Brick work in following Cement Mortar using best quality ground mould chamber burnt bricks of size 9\\" x 4 3/8\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally, other type of bond shall be done as directed by the Executive Engineer in charge. |
| 11 | CEMENT MOTAR |
| 12 | Plastering in C.M. 1:3 mix (one part of cement and three part of Sand) 10 mm tk including mixing and finishing to a well smoothened surface, watering cost and conveyance all materials and all labour and other incidental charges and other incidental charges etc., complete. as per standard specification TNBPSS 56,57 |
| 13 | Plastering in C.M. 1:5 mix (one part of cement and five part of Sand) 12mm tk including mixing and finishing to a well smoothened surface, watering cost and conveyance all materials and all labour and other incidental charges and other incidental charges etc., complete. as per standard specification TNBPSS 56,57 |
| 14 | Supplying and Painting the walls with two coats weather sealed exterior Emulsion Paint as instructed by the departmental officers including preparation of surface curing etc., copmlete in all floors complying with standard specification (The Colour and shade of paint shall be got approved the departmental officers) |
| 15 | Supplying and fixing of Steel door and Window using ISA Sections and MS Sheet of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 16 | Painting two coats with Enamel paint of approved colour and quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 17 | Paving the floor with colour and designed ceramic tiles 305mm x 305mm x 6mm of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. |
| 18 | Finishing the top of Roof with one course of machine pressed tiles of size ( 23x23x2 cm ) approved quality in C.M. 1:3 - 12 mm thick mixed with water proofing compoud confirming to IS @ 2 % by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc,. complete complying with Standard Specification |
| 19 | Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pip econcealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thickhy lum sheet cover with TW switch box and 5AFT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.) SD 26 |
| 20 | Wiring with 2x1.5 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with 150x100x113mm TW switch box for 5A 3 pinn on inter locking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open PVC plug point SD36 |
| 21 | Supply and fixing of 32 Amps DP Switch of 500 V with metal clad with fuse and neutral (Side Handle) on suitable TW Board , with earth connection only SD 144 |
| 22 | Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work SD 234 |
| 23 | Supply and fixing of TNEB meter Board suitable for 32A Single Phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. SD 125 |
| 24 | Supply and run of 4 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in 25 mm GI Pipe (B Class) suitably bend at both ends with necessary angle iron upright and end supports for mains (SD 72) |
| 25 | Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level witch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact. 2000lit capacity |
| 26 | 1000lit PVC Tank |
| 27 | Provision for coin Box and Platform |
| 28 | Drilling of borewell anywhere in Tamilnadu including transportation from one place to another place withinTamilnadu in alluvial soil or sedimentary strata of clay and sand or sand, stone, shale, pebbles, boulders etc., by firsttaking a pilot bore of 140 mm/150mm dia and then enlarging to required dia by direct or reverse rotatry mud and circulation method using Contractor's rig, fuel, labour, drilling, betonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit only Calyx drills are to be used.etc., complete. as per standard specification |
| 29 | Supply and Delivery of 150 mm dia PVC Casing Pipe of approved quality to require depth including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 30 | Supply and delivery of 1.50HP Single phase Submerssible Pumpset as per Is 8034 with out Panal Board including all labour charges etc,But Excluding Excise Duty&VAT (20 Lpm x 150mHead) etc.Complete |
| 31 | Supply and delivery of 1.50HP Single phase Panal Board With two level gurd and Auto Start including all labour charges etc But Excluding Excise Duty&VAT ,etc.Complete |
| 32 | Supply and delivery of pipes and pipes specials including all charges etc., |
| 33 | 4 sq.mm PVC insulted copper flat cable |
| 34 | 32 mm Dia B-Class G.I.Pipes(Medium) for submersible motors in borewell |
| 35 | 32 mm dia G.I.Coupling |
| 36 | 32 mm dia G.I.Bend |
| 37 | 32 mm dia G.I.Union |
| 38 | 32 mm dia G.M Gate valve & Non Return Valves |
| 39 | 150 mm dia Bore cap |
| 40 | 150 mm dia Bore Clamp set of 65mm Width |
| 41 | 20 mm dia G.I.Coupling |
| 42 | 20 mm dia G.I.Elbow |
| 43 | 20 mm dia Waste Not Tap |
| 44 | 16 Amps DPIC Main |
| 45 | Labour charges for the erection of submersible pumpset(Up To 5Hp) in Borewell including fixing jointing submersible cable with proper clamps up to starter to required depth ande also fixing of riser pipes to the recquired depth valves erection clamps,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter,Ammeter,Three pilot (indicating) lamps capacitor single phasing preventor,Water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days etc.Complete Please Enable Macros to View BoQ information |