| 1 | Ordinary repairs |
| 2 | 2.3.1.A:Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness <br> In area of light jungle - By Manual Means<br> |
| 3 | 16.18:Replacement of Damaged Concrete Railing. |
| 4 | 16.20:Replacement of Damaged Mild Steel Railing |
| 5 | 2.4.6.A:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres <br> Steel Work in all types of sections upto a height of 5 m above plinth level excluding cutting of rivet - -Including dismembering <br> |
| 6 | OD262433/2025-2026:Putting up ring bund as per approved shape 2.5m bottom width, 1m top width using empty gunny/polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund for an average height 2.50m including labour dismantling the bund after completion of the work etc. complete. |
| 7 | OD262437/2025-2026:Bailing out water using Pump above 5HP and up to 10HP- Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection, cost of fuel, lubrication oil and other stores, pay of staff etc. complete. |
| 8 | 12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. <br> Ordinary Soil - Depth upto 3m - Mechanical Means <br> |
| 9 | OD250307/2025-2026: Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
| 10 | 2.4.4.B:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres <br> Dismantling Stone Masonry - Rubble stone masonry in cement mortar.<br> |
| 11 | OD260002/2025-2026:DR with Departmental Stone- Dry Rubble Masonry- Dry rubble without concrete leveling course using departmental rubble including packing to compactness to lines and levels, labour charges, etc., complete as per direction of departmental officers at site (Derived from DAR (Civil) OD Irrigation 60.7.8) |
| 12 | OD260003/2025-2026:RR masonry with Departmental stone- Random Rubble Stone masonry (coursed/uncoursed) work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications |
| 13 | 13.4.A:Random Rubble Stone masonry (coursed/uncoursed) work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications |
| 14 | 13.5.B:Plain/Reinforced Cement Concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M20 - Height upto 5m |
| 15 | 13.5.F.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - Using concrete Mixer - Height upto 5m |
| 16 | 13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications |
| 17 | 14.7:Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, center to center spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. |
| 18 | 16.22:Repair of RCC Railing : Carrying out repair of RCC m30 railing to bring it to the original shape. |
| 19 | 55.10.1:Providing and erecting retro-reflectorised Object Hazard Marker 300mm x 900mm Providing and erecting retro-reflectorised Object Hazard Marker sign with 07 years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick / aluminium composit material sheeting 4 mm thick with suitable back support frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly fixed 30cm above ground level by means of properly designed foundation with M 15 grade cement concrete 30cmx30x45cm, 45cm below ground level including painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as per approved drawing and clause 801.300 mm x 900 mm |
| 20 | 8.6:Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 High Intensity Micro Prismatic (Type IV) grade sheeting fixed over aluminum sheeting, 2 mm thick/aluminum composite material sheeting 4 mm thick with an area exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on suitably designed GI pipe pole not less than 50mm NB , 2 Nos. confirming to IS 1239, firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. |
| 21 | 8.15:Supplying and installation of delineator (Roadway indicators) posts 80- 100cm high above ground level, pained black, and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorized panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification) |
| 22 | 55.14:Providing and fixing retro-reflectorised ceramic tilesProviding and fixing retro-reflectorised ceramic tiles of size 10cmX20cm using High Intensity Micro Prismatic (Type IV) grade sheeting with 7 years warranty fixed over Ist quality ceramic glazed tiles including cost of glue, cutting charges, fixing with suitable adhisive on concrete or other surface etc complete. |
| 23 | 12.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. |
| 24 | 12.8.G.1.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. <br> RCC Grade M30 - Using Concrete Mixer <br> |
| 25 | 13.5.G.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M30 - Using concrete Mixer - Height upto 5m |
| 26 | OD259632/2025-2026:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, G.I. pipes (Derived from DAR 10.26.3) |
| 27 | OD259712/2025-2026:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position all complete ( DAR 10.2) |
| 28 | OD261553/2025-2026:Hire and running charges of tipper |
| 29 | OD261554/2025-2026:Engaging mobile crane with all accessories |
| 30 | OD261555/2025-2026:Hiring chainsaw with motor for wood cutting |
| 31 | OD261556/2025-2026:Engaging wood cutter for cutting trees and branches standing in dangerous condition |
| 32 | OD262968/2025-2026:Engaging Coolie |
| 33 | OD319203/2025-2026:Micoconcrete with Epoxy bonding agent and Curing compound. Encasing the deterioted surface micro concrete so as to get a uniform size. Appying epoxy bonding agent on the existing concrete surface so as to get a well bonding with the new substract. Curing compund shall be applied immediately after setting the concrete. Two coats of saline based corrosion inhibitor, on the treated concrete surface so as to reduce the chloride ion attack. The rate shall include the cost of material, labour charges, hire charges of mixer machine. All complete as per manufactures specification and as per the instruction of engineer in charge. |
| 34 | OD319470/2025-2026:Welding by gas or electric plant including transportation of plant at site etc. complete.(Derived from CPWD Buildings Item No.10.22) |
| 35 | 8.9.A:Providing and applying two coats of Epoxy paint of approved brand on steel surface after through cleaning of surface to give an even shade |
| 36 | APPENDIX 1 |
| 37 | 13.52.2:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work Please Enable Macros to View BoQ information |