|
| 1 | cabin facilities |
| 2 | 10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 3 | 26.24.1:Providing and fixing in position wall panelling at all heights with integraldensified calcium silicate panels/tiles of size 595 x 595mm, having NRC (NoiseReduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectanceof 85% (minimum). Non combustible as per BS:476 (part-4), fire performanceas per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especiallyfabricated galvanised mild steel sheet 0.50 mm thick pressed section(galvanizing @120 grams per sqm including both sides) i.e.vertical studs ofsize 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceilingchannel section of size 50 x 32m fixed to the floor and soffit at 600mm centersusing 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with10mm bolt. This same channel is then to be fixed in horiziontal direction at600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of50mm thickness is then to be inserted in the slots and finally calcium silicatenon combustible panels/tiles are to be screw fixed with self tapping pan headnickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving aneven groove of 1 mm between the panels. The joints between the panels are tobe duly jointed and finished using recommended jointing calcium silicate basedcompound and fiber joint tape roll 50mm wide (90 metre )roll and two coats ofprimer suitable for panelling as per manufacturer's specification as perdirection of Engineer-in-Charge all complete.With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles |
| 4 | OD483940/2025-2026:od1278312/2021_2022 :Providing and fixing wall panelling with 7.5mm thick PVC wooden grains panel ofapproved quality with necessary screws etc complete OD 60 |
| 5 | 12.45.2:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conformingto IS: 2095- (Part 3):1996 (Boards with BIS certification marks) |
| 6 | 50.9.11.2:Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. |
| 7 | 50.9.11.1:Providing and fixing Thomson Multi wood board or equivalent make paneling 12 mm thick, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately) as per the direction of site Engineer-in-charge. |
| 8 | 21.13:Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete |
| 9 | 21.16.1:Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Anodized (AC 15 ) aluminium |
| 10 | 21.4.1:Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness |
| 11 | 9.115:providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer -in-charge. Please Enable Macros to View BoQ information |