| 1 | Footpath Lighting |
| 2 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 3 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 4 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 5 | OD256804/2024-2025:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | OD299532/2024-2025:Supply installation testing commissioning of Decorative pole of 3Mtr height hot dip galvanised GI suitable for wind speed as per IS 875 Part III 3 minimum thickness .The pole shall have two sections, lower section of dia. 114mm and length of 1mtr, upper section length of 2mtr and dia. 76mm. Pole shall be mounted on square base plate 250*250 *12 mm or nearest size thickness. The Pole Shaft should be fabricated out of Steel tube of grade YST 240. Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The complete structure shall be hot dip galvanized through 7 stage process and single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns before treating with primer. After galvanization structure shall be treated with two coats of high quality primer and thereafter coated with Polyurethane UV resistant coating paint (Marine grade paint) to minimum average DFT of 100 microns. The Pole shall of construction designed to withstand basic wind speed of as per IS 875 Part III. The complete structure should be hot dip galvanized and marine grade treated .The pole shall have inbuilt junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base foundation bolt 4 nos fixed in existing RCC foundation and junctions box Make Kesslec /Crompton /bajaj/K-Lite |
| 7 | OD299486/2024-2025:SITC of Decorative classic Post top LED street lantern of system wattage of 45W, BIS certified with a Graphite grey powder coated die- cast aluminum alloy spigot, Diffuser- Optical grade opal/ frosted PMMA with high bright discrete LED, with an optical block (IP65) with heat sink and an anti UV PC protector (IK06). Constant current electronic driver provided with high voltage and open circuit protection suitable for 60mm dia pole. colour rendering index (CRI) ;gt;70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV Make : BAJAJ BCF ANT 45W WW OP PT or equivalent. |
| 8 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 9 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 10 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 11 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 12 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 13 | 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 14 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 15 | OD31236/2025-2026:Supplying and fixing four pole sheet steel enclosure on surface/ recess along with 40 amps 415 volts "Double pole isolator complete with connections, testing and commissioning etc. as required. |
| 16 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Please Enable Macros to View BoQ information |