| 1 | CIVIL WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 6 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | Fabrication supply, conveyance & installation of Granite name board indicatingthe cost involved, the commencement, completion and inauguration date etc |
| 9 | Supply and fixing of name board with angles, flats, square pipe, ACP sheet includingnut and bolts. 2 nos per mast, 1Sqm in area. |
| 10 | ELECTRICAL WORKS |
| 11 | Supply installation testing and commissioning of High Mast using Octogaonal Polemade single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mmbottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part IIIwith head frame assembly two point suspension system with steel wire rope 5mm diadouble drum winching system w and including round arm galvanized luminarycarriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gearbox and lighting spikes with single phase operation power tool installed inside thebase compartment including connector foundation bolt 4 nos fixed in existing RCCfoundation and junction box etc, complete 12 Meters |
| 12 | Installation, testing and commissioning of 150W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 13 | Supply and installation of twin unit aviation LED obstruction light with stand yellowpainted die-cast aluminum alloy housing, red coloured poly carbonate dome and BC/ EC lamp holders suitable for LED lamp. |
| 14 | Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyas per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will betaken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCAsheet, powder coated (excluding base frame) |
| 15 | Supply and providing heavy duty 'A' section neoprene gasket in the panelboardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 16 | Supply and fixing of 1 no. of 25 A 4 Pole AC 1 rated power contractor ,25 Aconnector , 1 nos of Digital timer, suitable copper socket, 2.5 Sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable |
| 17 | Supply Conveyance and Installation of Surge protector device of IP 20,Mountingtype: Screw,Voltage protection level(UP),Nominal voltage:230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,NPE: 7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60 KA, Response time :<35 ns, Ta: -10-55 |
| 18 | Supply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switchfor motor control, supply and fixing flush head push button NO-NC, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 19 | Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 20 | Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |
| 21 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 22 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole and neutral. |
| 23 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 24 | Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 25 | Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 1.50 sq mm |
| 26 | Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.4 core 2.50 sq mm |
| 27 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired. |
| 28 | Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 29 | Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 30 | Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 31 | Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm |
| 32 | Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).4 core 4 sq mm |
| 33 | Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 34 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 35 | EXCLUSIVE OF GST Please Enable Macros to View BoQ information |