Name of Work:- GENERAL-Replacing damaged sewerlines and construction of manholes and allied works in ABC block in GMCK-Replacing damaged sewerlines and construction of manholes and allied works in ABC block in GMCK-General Civil Work
Sl. No.
Item Description
1
DETAILED ESTIMATE
2
OD342534/2025-2026:Supplying, laying and jointing 315 mm PVC Pipe for sewer line to line and grade in trenches up to a depth of 1.50m jointing with solvent cement and filling in with water and testing the line to the required pressure excluding earth work excavation etc. using pipe @ 6kgf/cm2 etc. complete.
3
OD283850/2025-2026: Constructing sewer manhole of size 80x80 inside and depth not exceeding of 120 cm with 20cm thick reinorced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab 120x120x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification
4
OD283849/2025-2026:od43788/2020_2021 : Constructing sewer manhole of size 80x80 inside and depth not exceeding of 90 cm with 20cm thick reinorced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab 120x120x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification
5
OD344059/2025-2026:Constructing sewer manhole of size 50x50 inside and depth not exceeding of 90 cm with 15cm thick reinforced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab80x80x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification Please Enable Macros to View BoQ information