| 1 | Civil Work |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) |
| 4 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 6 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 7 | 13.1.1 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand) |
| 8 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 9 | Electrical Work |
| 10 | 90.15.1.1 Supply, installation, testing and commissioning of Octagonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter, thickness 3 mm, base plate dimensions of 200 x 200 x 16 mm, suitable for windspeed as per IS 875 Part III, fixed head frame including round arm luminary carriage suitable to install 4/6 luminaries in symmetrical arrangement including connector, foundation bolt 4 nos, existing RCC foundation and junction box etc., complete. 8 Meters height |
| 11 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | OD362560/2025-2026Supply of Syntex Make Panel suitable to install Meter for electricity supply and otheraccessones mace out of Sheet Moulding Compound (560 x 280x 150 mm size)Surface mounted or recess-in wa (Indoor/Outdoor Use) One piece moulded SMC baseand SMC door with internal hinges. Knockout for wire entry, earthing bolt. IncludesContactor, MCB, Connector, Digital Timer, RCCB, HRC Fuse Base with HRC Fuselink, 2 Way neutral links, Earth Wire, Banana Al. socket, 2.5 sq. mm ISI marked,FRLS PVC insulated, single core copper conductor cable. |
| 13 | OD362561/2025-2026Supply Conveyance and Installation of Surge protector device of IP 20 Mounting type: Screw, Voltageproctection level (UP), Nominal voltage : 230V, UOC: 10KV, L-N:7 KV , L-PE:7KV,N-PE:7 KV, Nominaldischarge current (8/20): 10KA, Tottal discharge current (8/20): 60 KA, Responsetime: <35 ns, Ta: -10-55 |
| 14 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panelboardU' section rubber beeding suitable for 1.60/ 2.00 mm shee |
| 15 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |
| 16 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 17 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 1.50 sq mm |
| 18 | 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 19 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 20 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 21 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 22 | 90.12.5.3Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 23 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 24 | 9.1.2Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 25 | OD362889/2025-2026Fabrication ,supply, conveyance and installation of Granite name board indicating thecost involved, the commencement, completion and inauguration date etc |
| 26 | Connection charges - KSEB Please Enable Macros to View BoQ information |