| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/in All kind of soil (Where blasting Prohibited) for foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan),including dressing of sides and ramming of bottoms,lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m complete all as specified and as directed |
| 2 | Returning, filling in the any type of soil including spreading, levelling. Watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed. |
| 3 | Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar all as specified and directed. |
| 4 | M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified. |
| 5 | M&L random rubble stone masonary well bonded bedded solidily hearted in CM 1:4. |
| 6 | -ditto- as above but except stones. |
| 7 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed |
| 8 | M&L for 10mm thick rendering on fair faces of brick works finished even andfair without using extra cement in cement mortar 1: 4 complete all as specified and as directed |
| 9 | M&L for 15 mm thick rendering on stone masonry works or other than fair faces of brick work or concrete surface finished even and fair without using extra cement in cement mortar 1: 4 complete all as specified and as directed |
| 10 | M&L for 20 mm thick rendering on stone masonry works or other than fair faces of brick work or concrete surface finished even and fair without using extra cement in cement mortar 1: 4 complete all as specified and as directed |
| 11 | Supply only liquid water proofing compound |
| 12 | M&L for preperation of new plastered wall surface of any description and applying two coat of cement based paint over a coat of chalk whiting complete all as specified and as directed. |
| 13 | M&L for preperation of old plastered wall surface of any description and applayng one coat of cement based paint complete all as specified and as directed. |
| 14 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness(below or above GL) complete all as specified and directed by Engineer in charge. |
| 15 | M&L for PCC 1:4:8 type, D2 (40mm graded stone agg.) as in foundation filling and mass concrete |
| 16 | M & L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping and surface channel including necessary form work. |
| 17 | Supply and fix FRP manhole cover (900mm X 450mm X 50mm) all as specified and directed by E-in-Charge |
| 18 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 150/160mm dia complete all as specified and as directed by the Engineer-in-Charge |
| 19 | M&L for Reinforced concrete pipes, class NP2, 150mm dia laid in trenches and jointed complete with collars all as specified and directed |
| 20 | M&L for cement concrete C-2 (1:3:6) for 150mm pipe bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 21 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 200/225mm dia complete all as specified and as directed by the Engineer-in-Charge |
| 22 | M&L for Reinforced concrete pipes, class NP2, 200mm dia laid in trenches and jointed complete with collars all as specified and directed |
| 23 | M&L for cement concrete C-2 (1:3:6) for 200 mm pipe bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 24 | Material and Labour for cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 100/110 mm bore pipe complete all as specified and as directed by Engineer-in-Charge . |
| 25 | Material and Labour for cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 150/160mm bore pipe complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Material and Labour for cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 200/225mm bore pipe complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Dismantling of CI/PVC drain pipes 50 to 110 mm |
| 28 | S&F 110mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 29 | S&F 110mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed in walls complete all as specified and directed. |
| 30 | S&F 75 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 31 | S&F 75mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed in walls complete all as specified and directed. |
| 32 | S&F in repair 110mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed. |
| 33 | S&F in repair 75 mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed. |
| 34 | S&F in repair 110mm bore PVC (SWR) branch piece, single T with access door equal or unequal complete all as specified and directed. |
| 35 | S&F in repair PVC (SWR) Reducers all as specified and directed. |
| 36 | S&F in repair 75mm bore PVC (SWR) branch piece, single T with acess door equal or unequal complete all as specified and directed. |
| 37 | S &F in repair PVC (SWR) Vent cowl all as specified and directed. |
| 38 | The labour attend daily complaint and covered the following items:- (a) Cleaning and cleanring of blocked IWCs & EWCs to sewage line upto 1st manholes by rodding or any other suitable method & taking out the muck, mud and other debris from WCs and the sewage line cleaning with fresh water & removing the debris upto a distance exceeding 200M and not exceeding 250 M and covering the same with a layer of soil not less than 15cm thick all as directed by Engineer-in-Charge. (c)Cleaning of clearing of blocked chocked floor trap in kitchen & bathrooms including gully trap, the waste water line connection etc by rodding or by any other suitable method & taking out the debris to a distance exceeding 200m & not exceeding 250m & covering the same with a layer of soil not less than 15cm thick complete and drain out the floors taps, gully traps waste pipe and soil pipe with fresh water etc complete all as directed by Engineer-in-Charge. Note:- The contractor employ sufficient No of labour and at least one supervisor collet complaint slip each day from complaint cell. If any complaint will not attend by the contractor, Rs. 500 will be recovered per complaint. |
| 39 | M & L for Removal of blockage of sewage lines up to 150mm dia including manholes by using necessary tools/mechanically tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe well with water after removal of blockage and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around slope all complete as required and directed. |
| 40 | M & L for Removal of blockage of sewage lines exc 150mm but n exc 250mm dia including manholes by using necessary tools/mechanically tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe well with water after removal of blockage and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around slope all complete as required and directed. |
| 41 | M & L for Removal of blockage of sewage lines exc 250mm but n exc 450mm dia including manholes by using necessary tools/mechanically tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe well with water after removal of blockage and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around slope all complete as required and directed. |
| 42 | Note for ser item No 38 to 46:- (i) The rates quoted in the above item includes cost of T&P like rods, bamboos, gum shoes and hand glouses etc complete(ii) Minimum one sweeper and one helper shall be deployed by contractor and they shall be present on all days from 0900 hrs to 1700 hrs including holiday and Sunday for maintenance of sewage lines. The persons will be detailed by JE/AGE concerned every morning for attending complaints on daily basis.(iii) The complaint has to be rectified within 24 Hrs as given in complaint slip failing which penalty will be imposed @ 500/- per complaint per day and for ser no (ii) also. |
| 43 | M& L for Taking out silt, liquid water sludge in solid/semi solid state from septic tank/Manholes STP tanks of any capacity and size and removing the same using truck mounted honey sucker of capacity minimum 8 cum and to dispose off the sludge to in low lying area at any distance including Sunday and holiday as per requirement depositing the sludge in low laying area with covering by earth over it and leaving the septic tank/sump clean etc. all as specified complete. Note : Driver and operator must be passes a valid license and confirm the serviceability of the Truck. |
| 44 | M & L for Cleaning of sewer line by mechanically by truck mounted sewage cleaning of sewage line water sludge tank with wash down system / suck derrick arm hydraulically spring loaded rotary sliding vane compressor with V hose end section no 33 nozzle and strainer all as specified and as directed by Engr-in-Charge. |
| 45 | Taking out (desilting) silt brick bats, debris , liquid waste sludge in solid/semi solid state from manholes including pumping out sludge wherever necessary diverting the flow in the drain , if necessary and stacking the removed silts in depots away from the edge of manholes as directed including use of sfery belts, dry cells torch for lighting inside the manholes and taking similar precautionary measures and removing the sludge etc to a distance exc 250 mtr but not exc 500m & leveling the manhole cleaned and flushed with water etc all as specified /directed manholes up to the depth of 1.00 mtr. |
| 46 | Taking out (desilting) silt brick bats, debris , liquid waste sludge in solid/semi solid state from manholes including pumping out sludge wherever necessary diverting the flow in the drain , if necessary and stacking the removed silts in depots away from the edge of manholes as directed including use of sfery belts, dry cells torch for lighting inside the manholes and taking similar precautionary measures and removing the sludge etc to a distance exc 250 mtr but not exc 500m & leveling the manhole cleaned and flushed with water etc all as specified /directed manholes up to the depth of exc 1.00 mtr. but n exc 2.00mtr |
| 47 | Taking out (desilting) silt brick bats, debris , liquid waste sludge in solid/semi solid state from manholes including pumping out sludge wherever necessary diverting the flow in the drain , if necessary and stacking the removed silts in depots away from the edge of manholes as directed including use of sfery belts, dry cells torch for lighting inside the manholes and taking similar precautionary measures and removing the sludge etc to a distance exc 250 mtr but not exc 500m & leveling the manhole cleaned and flushed with water etc all as specified /directed manholes up to the depth of exc 2.00 mtr |
| 48 | S & F PVC (SWR) gully trap 110 mm dia fixed in cement concrete including removal of existing old damaged gully traps and providing connection upto 1st manhole with PVC pipe complete all as specified and directed. |
| 49 | S&F vitreous chinaware EWC including connection to drain or outgoing pipe and to PVC flushing pipe, antisyphonage pipe, PVC low level flushing cistern 10 ltr capacity with brackets of approval Make and all necessary fittings etc complete all as directed and specified incl PVC seat cover fixed in repair all as specified and directed. |
| 50 | S & F in repair floor gratings 100mm dia with o without waste hole of PTMT (mim waight 40 grms) all as directed by the Engr-in-Charge |
| 51 | S&F waste pipe of polyethylene of low or high density or PVC ,32 mm dia for wash basin/ sink /flush tank fixed in repairs. complete all as directed by Engr-in-charge. |
| 52 | S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms). |
| 53 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 54 | M&L for coloured Non skid ceramic tiles of size 300x300mmx7mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed in CM (1:6). |
| 55 | M&L Glazed Ceramic Coloured Tiles, 300X200X7/450x300x7/600x300x7mm in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. |
| 56 | Supply and fix Vitreous china Squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding in repairs |
| 57 | S & F in repair PVC low level flushing system plastic valve with inlet ball valve float chain and ball (of capacity 10 liters) ISI Marked incl 32mm PVC flush pipe complete all as specified and directed |
| 58 | S & F in repair Vitreous China wash basin, white, flat back, size 550 x 450mm including brackets all as specified and directed. |
| 59 | S&F in repairs 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with cromium plated brass screws and cup washers complete all as specified. |
| 60 | S & F in repairs 15 mm bore pillar taps, fancy type Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe |
| 61 | S&F in repairs PVC connection pipe suitable for connecting flushing cistern and WHB etc 450mm long complete all as specified and directed. |
| 62 | S&F vitreous China bowl urinal flat back size 465 X365 X 265mm white (minimum) withgrating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixed in repairs complete all as specified and directed |
| 63 | Disconnecting existing exc 250 Ltr and incl 500 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc removing scale and dirt from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position including (a) Removal of algae/dust/mud,foreign material from tank(sides and bottom) with wire brushes & washing with bleeching powder and water (b) Collecting all above sludge on cane bucket and throwing it not less than 50mtr beyond the area where directed by Engineer-in-Charge (c)Cleaning of complete tank (internally) with fresh water and draining again.complete all as directed by Engineer-in-Charge. complete all as specified and directed. |
| 64 | Disconnecting existing exc 500 Ltr and upto 1000 Ltr capacity tank , setting aside (or lowering if required) for repairs, cleaning, etc removing scale and dirt from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position including (a) Removal of algae/dust/mud,foreign material from tank(sides and bottom) with wire brushes & washing with bleeching powder and water (b) Collecting all above sludge on cane bucket and throwing it not less than 50mtr beyond the area where directed by Engineer-in-Charge (c)Cleaning of complete tank (internally) with fresh water and draining again.complete all as directed by Engineer-in-Charge. complete all as specified and directed. |
| 65 | S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 500 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I |
| 66 | S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I |
| 67 | Demolition of cement concrete in ground floor and pavings n'exc 15cm thickness (below or above ground level complete all as specified and as directed). |
| 68 | M & L for 75 mm thick PCC 1:4:8 type D-2 using 20mm graded aggregate as sub flooring all as specified and direcetd. |
| 69 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and properembedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand |
| 70 | M&L Glossy finish machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickiness M-35 grade complete all as specified and as directed by Engr-in-Charge.. |
| 71 | M & L for 75 mm PCC 1:3:6 type C-2 using 20mm graded aggregate as in floors ,Hard standing and pavings finished with spike rolling to surface or making impressions of expanded metal ,whilst the concrete is green all as specified and directed. |
| 72 | M&L Forming Contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'B' in plinth protection |
| 73 | Dismantling chain link fencing/expanded metal or mesh not exceeding 4kg/Sqm fixed in steel, wood fillets, concrete post etc. of any description. |
| 74 | Fixing only Chain link fencing including line wires, any mesh size and type to any type of standards,rails, straining bolts,etc.including provision of binding wire. |
| 75 | Supply only chain link MS galvanised fencing of weight not less than 3.5 Kgs per sqm and size as directed by Engr-in-charge. |
| 76 | S & F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) incl removal of old unservicebale barbed wire. |
| 77 | Restraining resecuring including making good staples etc Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) incl removal of old unservicebale barbed wire. |
| 78 | S& F in repairs wire entanglements wth galvanised steel concertina coil of dia 600 mm reinforced with punched (chrome rajor of blade wire) barbed tape of 2.5mm thick galvanized steel sheet at 75mm saplings and core wire of dia 2.24mm high tensile steel wire complete all as specified and directed by the Engr-in-Charge. |
| 79 | M&L for preparation new steel surfaces of any description, not otherwise described, over 10cm width/girth and applying two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified and as directed |
| 80 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 81 | M&L for Fe 410-W (GdeE- 250) quality A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 82 | Supply and fixing mild steel work as in angle iron, flat iron of any size for post and struts as in fencing including, cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets for securing wire mesh ,chain link fencing etc including all necessary drilling bolting or riveting etc and/or fixing with screws, bolts etc. and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed. |
| 83 | Providing and fixing Precast cement concrete louvers and jallies 25mm thick Type B0 1:2:4(20mm graded aggregate) (measured solid) set in cement mortar 1:4 ,including all moulding but excluding frame(pre cast frame shall be measured separately as Item above) |
| 84 | M&L PCC 1:3:6 type C2 (using 40mm graded aggregate) in fdn, filling and mass concrete for fencing posts and similar work |
| 85 | Demolition of stone slabs and chequired tiles of any description or thickness in floors aprons etc.laid bedded and pointed in any mortar. |
| 86 | M & L for grantite 20mm thick (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing width white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed. |
| 87 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incluidng rubbing and polishing complete including screed bed 20mm thick in cement motar 1:6 complete all as specified and directed. |
| 88 | M & L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with over a 10mm thick plaster in CM 1:3 all as specified and directed. |
| 89 | M&L PCC 1:2:4, 25 mm thick type B0 using 12.5mm graded stone aggregate as in floor finished even and fair with out using extra cement complete all as directed by Engr-in-charge. |
| 90 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), all as specified and as directed |
| 91 | M&L form work to rough finished surface to sides of beams, sides and sofits (if any) of foundations and plinth beams and similar works: verticals or to batter |
| 92 | M&L RCC type M20,1:1.5:3 in beams,plinth beams,Lintels etc,basement slabs , under reamed piles ad mass concrete. |
| 93 | M&L for brocken glass coping on top walls in cement mortar 1:3 including dimolition of old existing glass coping(if required) and removing the rubbish |
| 94 | S & F mild steel TMT bars 10mm dia & over as in reinforcement including cutting, cranking bending & binding with mild steel annealed wire not less than 0.9mm dia or securing with clip. |
| 95 | Ditto but 8 mm dia in stirrups, spacers and binders |
| 96 | S&F Pre-painted galvalume sheet zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, view cutter fixed with self tapping screws as specified and directed. Please Enable Macros to View BoQ information |