| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft and loose soil/Road Cutting complete all as specified and directed. |
| 2 | Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. |
| 3 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | M&L HDPE double wall Corrugated Duct Pipe for Cable Protection laid in trench of 40 mm OD complete all as specified and directed. |
| 5 | All as per ser item No 4 above, but for 63 mm OD complete all as specified and directed. |
| 6 | All as per ser item No 4 here in before, but for 90 mm OD complete all as specified and directed. |
| 7 | M&L for river washed and screened, dry sand for filling in trenches below and around underground cable for cushioning of cable complete all as specified and directed. (Note: Punned thickness shall be measured) |
| 8 | Supply and lay well burnt/Fly ash brick of size 200x100x80mm locally available as protection of cable in trenches complete all as specified and directed. |
| 9 | Taking up/down existing defective cable of sizes 3.5/4 core 10 to 50 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station complete all as specified and directed. |
| 10 | Laying, jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floor/roof/ceiling etc of size 2/3/3.5/4 core 10 to 50 sqmm including necessary cable lugs, gland etc complete all as specified and directed. |
| 11 | Supply, laying, Testing & commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable , (heavy duty), 1100 volts grade with stranded aluminium conductor including necessary cable lugs, gland etc of 400 Sqmm 3.5 Core size complete all as specified and directed. |
| 12 | All as per ser item No 11 above, but of 300 Sqmm 3.5 Core complete all as specified and directed. |
| 13 | All as per ser item No 11 here in before, but of 240 Sqmm 3.5 Core complete all as specified and directed. |
| 14 | All as per ser item No 11 here in before, but of 185 Sqmm 3.5 Core complete all as specified and directed. |
| 15 | All as per ser item No 11 here in before, but of 150 Sqmm 3.5 Core complete all as specified and directed. |
| 16 | All as per ser item No 11 here in before, but of 120 Sqmm 3.5 Core complete all as specified and directed. |
| 17 | All as per ser item No 11 here in before, but of 95 Sqmm 3.5 Core complete all as specified and directed. |
| 18 | All as per ser item No 11 here in before, but of 70 Sqmm 3.5 Core complete all as specified and directed. |
| 19 | All as per ser item No 11 here in before, but of 50 Sqmm 3.5 Core complete all as specified and directed. |
| 20 | All as per ser item No 11 here in before, but of 35 Sqmm 3.5 Core complete all as specified and directed. |
| 21 | All as per ser item No 11 here in before, but of 25 Sqmm 3.5 Core complete all as specified and directed. |
| 22 | All as per ser item No 11 here in before, but of 16 Sqmm 4 Core complete all as specified and directed. |
| 23 | All as per ser item No 11 here in before, but of 16 Sqmm 2 Core complete all as specified and directed. |
| 24 | All as per ser item No 11 here in before, but of 10 Sqmm 4 Core complete all as specified and directed. |
| 25 | All as per ser item No 11 here in before, but of 10 Sqmm 2 Core complete all as specified and directed. |
| 26 | Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads in drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, pipes of 150 mm bore size complete all as specified and directed. |
| 27 | All as per ser item No 26 above, but of 100 mm bore size complete all as specified and directed. |
| 28 | All as per ser item No 26 here in before, but of 80mm bore size complete all as specified and directed. |
| 29 | All as per ser item No 26 here in before, but of 40mm bore size complete all as specified and directed. |
| 30 | M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the existing surface complete all as specified and with PCC 1:3:6 type C1 by (using 20 mm graded granite stone aggregate)100 mm thick for making good the surface where road cutting/ hard standing/ paths and Removing excavated/demolished material to a distance n.exc. 50m complete all as specified and directed. |
| 31 | M&L for LT indoor end termination Kit (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including all jointing accessories for making joints for the cable of 400 Sqmm to 500 Sqmm sizes 3/3.5/4 core including testing complete all as specified and directed. |
| 32 | All as per ser item No 31 above, but of 185 Sqmm to 300 Sqmm complete all as specified and directed. |
| 33 | All as per ser item No 31 here in before, but of 70 Sqmm to 150 Sqmm complete all as specified and directed. |
| 34 | NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |