| 1 | Civil Works |
| 2 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 3 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 4 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 5 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | $Electrical Works |
| 9 | 90.15.1.1 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters |
| 10 | 90.15.4.9 : Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 11 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 12 | OD334120/2025-2026Supply of Syntex Make Panel suitable to install Meter for electricity supply andother accessories made out of Sheet Moulding Compound (560 x 280x 150 mmsize/ nearest size) Surface mounted or recess-in wall (Indoor/Outdoor Use) One piecemoulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthingbolt. Includes Contactor, MCB , Connector, Digital Timer, RCCB, HRC Fuse Basewith HRC Fuse link, 2 Way neutral links, Earth Wire, Banana Al. socket, 2.5 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 13 | 90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 14 | OD334118/2025-2026Supply and fixing of Surge protector device of IP 20,Mounting type: Screw,Voltageprotection level(UP),Nominal voltage: 230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,NPE:7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60KA, Response time :<35 ns, Ta: -10-55. |
| 15 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 16 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke andsalt ) as required |
| 17 | OD334121/2025-2026Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below ground including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
| 18 | 90.12.1.3Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm |
| 19 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 20 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 21 | 9.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 22 | OD334116/2025-2026Supply and fixing of Name Board of MLA, with Angles ,Flats, Square Pipe, ACPSheet (complete 4 sides) including Nut and bolt |
| 23 | OD334117/2025-2026Supply and fixing of Granite Plaque engraved with the name of MLA , name ofProject,Name of Plan, Location, Name of LSGD ,Year of Project, Estimate Costand Name of implementing agency Please Enable Macros to View BoQ information |