| 1 | Dismantling of boarding in wall/ceiling, any description, fixed in any position with nails or screws complete all as specified and directed.Note: Taking down carefully old FTL fitting recessed mounted light fittings/ceiling complete with all accessories and making necessary electric connection, complete all as specifiedd & directed by Engr-in charge. |
| 2 | M&L for 9mm Pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws/nails to timber frame work in wall portion complete all as specified and directed. |
| 3 | Providing & fixing false ceiling with semi perforated 8-9mm thick micro tegular edged GRG at all heights with GRG false ceiling tiles of size 595X 595 mm of approved texture design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS476(part4)-1970 and light reflectance of 85%(min) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanised iron sec of 0.33 mm thick (galvanised @ 120 grams per sqm incl both sides) comprising of main -T runners of size 15x 32 mm of length 3000mm ,cross-T of size 15X32 mm of length 600 mm to form grid module of size 600 x600 mm suspended from ceiling using galvanized mild steel items (galvanizing @80mm per sqm ) i'e 50mm long 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 x 25 x 2 mm ,Galvanised iron perimeter wall angle of size 24 x 24x 0.40 mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws.The work shall be carried out as per specifications, drawing and as per directions of the Engr-in-Charge. |
| 4 | Dismantling of timber scantling in fillets, posts, rafters, purlins etc under 40Sq. Cm in section in framed work complete all as specified and directed. |
| 5 | M&L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area exc 13 Sqcm and not exc 25sqcm secured with nails complete all as specified and directed. |
| 6 | M&L for 2nd class soft wood fillets sectional area exc 3 and n exc 6 sqcm rectangular or triangular in section but bullnosed, splayed, chamfered or rounded on one edge of face, secured with nails or brads, complete all as specified and as directed. |
| 7 | Dismantling of plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering/wall complete all as specifed and directed. |
| 8 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws having EPDM washer complete all as specified |
| 9 | S&F for 0.50mm thick CGI sheets fixed to wall/roof with two corrogations side lap, fixed with L- type or J type or cranked hook bolts and washers with grade of zinc coating 275 complete all as specified and directed. |
| 10 | S&F 0.50 mm thick plain galvanised mild steel sheeting, in ridges, hips, valley gutter, drip and straight flashings fixed with L- type or J type or cranked hook bolts and washers with grade of zinc coating 275 complete all as specified and directed. |
| 11 | M&L for two coat of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description, not otherwise described over 10cm width or girth incl preparing new zinc or galvanised surfaces to receive painting by coating with mordant solution incl washing and cleaning etc completed all as specified and directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 13 | M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed. |
| 14 | M&L for coloured light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15 mm thick screed bed or bedding of cement mortar (1:6) complete all as specified and directed. |
| 15 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 16 | S&F for SDC Laminated flooring 8mm thick of any coloured manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base complete all as direceted by Engr-in-Charge. |
| 17 | Taking down of chowkats with shutter (without taking of shutter from frame) n exc 1.5 Sqm each complete all as specified and directed. |
| 18 | Taking down of chowkats with shutter (without taking of shutter from frame) exc 1.5 Sqm but n exc 4.0 Sqm each complete all as specified and directed. |
| 19 | Taking down shutter only exc 2 sq. m each complete all as specified and directed. |
| 20 | Taking down shutter exc 1 sq. m and n exc 2 sq. m each and refixing in the same opening after minor repairs complete all as specified as direted |
| 21 | Taking down shutter exc 2 sq. m each and refixing in the same opening after minor repairs complete all as specified as direted |
| 22 | S&F of 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 23 | S&F plain 2nd class hardwood 35mm thich framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 24 | S&F for 30mm thick 2nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) completed all as specified and directed. |
| 25 | Supply and fixing for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-charge. |
| 26 | Supply and fixing for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, & bottom rail, lock rail & bottom rail on either side & as gap insert for top rail & colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed |
| 27 | S&F of 100mm size, butt hinges, cold rolled steel or stainless steel with screw, medium weight , ISI marked complete all as specified and directed. |
| 28 | S&F 150 mm long Aluminium, anodised, barrel tower bolt, Mild steel or stainless steel having dia/shoot not less than 10 mm with screws complete all as specified and directed. |
| 29 | S&F 150 mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed. |
| 30 | S&F of 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 31 | S&F of 300mm long, Mild steel or stainless steel, sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 32 | M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 33 | M&L fixed in repairs for Aluminium extruded section Door closer hydraulically regulated, designation No 2 universal type,suitable for door shutters of 851 to 1000 mmm in width and weight between 61 to 80 kg complete all as specified and directed. |
| 34 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, light fitting cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 35 | M&L for point wiring complete for one light point / exhaust fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Make of Wire : Havells / Standard / KEI / C&S / RR Kabel / Polycab. |
| 36 | Description all as per srl item no. 35.00 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board. |
| 37 | Description all as per srl item no. 35.00 here-in-before but for one socket outlet 3 pin, 5 Amps on same board. |
| 38 | Description all as per srl item no. 35.00 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.Note : The point wiring for power point will not be mixed with light/fan point circuit. |
| 39 | S & F Modular switch 1 way 6A , 1 module size completed all as directed by Engr-in-Charge. |
| 40 | S & F Modular switch 1 way 16A , 1 module size completed all as directed by Engr-in-Charge. |
| 41 | S & F Modular Bell push 1 way 6A , 1 module size completed all as directed by Engr-in-Charge. |
| 42 | S & F Modular Socket , 6 A , 5 Pin , 2 module size completed all as directed by Engr-in-Charge. |
| 43 | S & F Modular Socket , 6 A / 16 A , 5 Pin , 2 module size completed all as directed by Engr-in-Charge. |
| 44 | S&F, in replacement of Modular blank plate 01 Module size completed all as directed by Engr-in-Charge. |
| 45 | S & F Modular cover plate with frame 6 module completed all as directed by Engr-in-Charge. |
| 46 | S & F Modular cover plate with frame 4 module completed all as directed by Engr-in-Charge. |
| 47 | S & F Modular cover plate with frame 3 module completed all as directed by Engr-in-Charge. |
| 48 | S & F Modular cover plate with frame 2 module completed all as directed by Engr-in-Charge. |
| 49 | S & F Modular cover plate with frame 1 module completed all as directed by Engr-in-Charge. |
| 50 | S & F Modular metal flash box 6 module completed all as directed by Engr-in-Charge. |
| 51 | S & F Modular metal flash box 4 module completed all as directed by Engr-in-Charge. |
| 52 | S & F Modular metal flash box 3 module completed all as directed by Engr-in-Charge. |
| 53 | S & F Modular metal flash box 1/2 module completed all as directed by Engr-in-Charge.Note: Make of Modular switches / sockets and other accessories : Anchor / Legrand / Havells Please Enable Macros to View BoQ information |
| 54 | S & F Modular metal flash box 1/2 module completed all as directed by Engr-in-Charge.Note: Make of Modular switches / sockets and other accessories : Anchor / Legrand / Havells Please Enable Macros to View BoQ information |