| 1 | Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc complete all as specified & directed. |
| 2 | M&L for Point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLSH type drawn through and including PVC concealed conduit / casing caping (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, including 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLSH type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for the following:- Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 3 | One light point / one fan point controlled by one, one way swtich complete all as specified & directed. |
| 4 | One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire complete all as specified & directed. |
| 5 | All as per BOQ serial item No. 2.01 above but on independent board complete all as specified & directed. |
| 6 | All as per ser item No. 2.01 above but with 2.5 Sqmm PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes. |
| 7 | All as per BOQ serial item No. 2.01 above but one light point controlled by 2 way switches complete all as specified & directed. |
| 8 | All as per BOQ serial item No. 2.01 above but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified & directed. |
| 9 | S&F in repairs of switch piano flush button 5 Amp single pole one way 230 volts white finish complete all as specified & directed. |
| 10 | S&F in repairs of bell push, 230 volts white finish complete all as specified & directed. |
| 11 | S&F in repairs of socket outlet flush type 2 in 1,3 pin 5 Amp 230 volts white/ivory finish complete all as specified & directed. |
| 12 | S&F in repairs of 16 Amp switch flush type 230 volts single pole white/ivory finish complete all as specified & directed. |
| 13 | S&F in repairs of socket multipurpose flush type 2 in 1 type (3 and 3 pin ) 5/16 Amps, 230V, AC white / ivory finish complete all as specified & directed. |
| 14 | S&F in repairs of switch piano flush button 5 Amp single pole 2 way 230 volts white finish complete all as specified & directed. |
| 15 | S&F in repairs switch socket combination 3 pin , 16 Amp flush type, complete all as specified & directed. |
| 16 | S&Fin repairs angle type Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified & directed. |
| 17 | S&F in repairs ceiling rose surface bakelite three terminal (65x50) mm, PVC/Polycarbonate, isolated body complete all as specified and as directed. |
| 18 | S&F in repairs of step type fan regulator complete all as specified and directed. |
| 19 | S&F in repairs LED Lamp, 09Watt, B22 base complete all as specified & directed.Make-Cat No: Orient Cat Part no :High Glo B22d/ E27/Philips/Crompton or equivalent make as approved by GE |
| 20 | S&F in repairs LED tube 20 W Tube light fitting LED Batten with aluminum housing and integrated electronic driver with square profile extruded connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as specified & directed. Make-Cat No: Orient Cat Part no : LBLN-20-C-SQ-AL/Philips/Crompton or equivalent make as approved by GE |
| 21 | S&F in repairs LED 9/10 W Tube light fitting LED Batten extruded and polycarbonate connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as specified & directed. Make-Cat No: Orient Cat Part no :LBLN-10-C-SQ /Philips/Crompton or equivalent make as approved by GE |
| 22 | S&F in repairs bldg security lighting of LED 30 watts high efficennt lighting solution anodised with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters of suitable diameter(as required at site) complete all as specified and as directed. Make: Cat No: Orient Cat Part no :LSFT-030-C/Philips/Crompton or equivalent make as approved by GE |
| 23 | S&F in repairs of energy saver, LED bulkhead, light fittings, 10 Watts complete with all accessories prewired incl three core copper cable 23/0.0076 from ceiling rose to light fittings complete all as specified & directed. Make: Orient/Philips/Wipro or equivalent make as approved by GE |
| 24 | S&F in repairs MCB DB double door with necessary lugs for incomming and outgong connections up to Copper/Aluminium conductor og 16 sq mm fixed on wall surface/concealed complete all as specified & directed for the following : |
| 25 | MCB, DB, SPN 4 Way |
| 26 | MCB, DB, SPN 8 Way |
| 27 | MCB, DB, SPN 12 Way |
| 28 | MCB, DB, TPN 4 way |
| 29 | Supply and fix in repairs MCB of following rating complete all as specified & directed. |
| 30 | MCB SP 6 to 40 Amp |
| 31 | MCB DP 6 to 40 Amp |
| 32 | MCB TP 6 to 40 Amp |
| 33 | MCB TPN 40 to 63 Amp |
| 34 | S&F in repairs MCCB, 415 V, of following capacity complete all as specified & directed. |
| 35 | 63 Amps, 4 pole, 16 KA |
| 36 | 100 Amps, 4 pole, 16 KA |
| 37 | 125 Amps, 4 pole, 16 KA |
| 38 | Supply and laying or fixing in replacement twin sub main cable with (2 x 4) Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable including contineous earth wire (1 x 4) Sqmm copper conductor insulated unsheathed complete all as specified & directed in the following:- |
| 39 | In PVC concealed conduit |
| 40 | In PVC casing caping |
| 41 | Supply and laying or fixing in replacement twin sub main cable with (2 x 6) Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable , in pvc casing caping including contineous earth wire (1 x 6) Sqmm copper conductor insulated unsheathed complete all as specified & directed in the following: |
| 42 | In PVC concealed conduit |
| 43 | In PVC casing caping |
| 44 | S&F in repairs of PVC rectangular block of sizes of following size for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement complete all as specified & directed. |
| 45 | 100 mm X100 mm square,50 mm deep |
| 46 | 175 mmX100 mm , 50 mm deep |
| 47 | 200mmX150 mm , 50 mm deep |
| 48 | 250mmX200 mm 50 mm deep |
| 49 | S&F industrial laminated sheet board/hylem sheet of any size 6 mm thick of any size for for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing laminated top cover complete all as specified & directed. |
| 50 | M&L for point wiring with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathed FRLSH cable, copper conductor multistranded passing through including concealed PVC conduit not than 20 mm dia with concealed modular box suitable for logic modular switches , sockets , etc with logic modular white plates, sorroundings of suitable size as required at site with PVC insulated FRLSH unsheathed stranded copper conductor of size 1.5 sq mm as earth wire connected to common earth dully as specified complete all as specified and directed for the following:- Note: - (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good to the walls (No extra payment will be made for the same)(ii) Rate quoted shall also include for cost of cover plate and blank plates as per site requirement (No extra payment will be made for the same) |
| 51 | One light point / one fan point controlled by one, one way swtich |
| 52 | One light point controlled by two way switch complete all as specified & directed. |
| 53 | One 3 pin 6 Amps socket modular type on the same board with 1.5 sqmm cable complete all as specified & directed. |
| 54 | One 3 pin 6 Amps socket modular type on the independent board with 1.5 sqmm cable complete all as specified & directed. |
| 55 | All as per BOQ Serial item No 25.00 above but for socket modular type 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 2.5 sqmm copper conductor cable as earth continuity conductor complete all as specified & directed. |
| 56 | All as per BOQ Serial item No 25.00 above but for socket modular type 2 in 1,3 pin 5/15 Amp on independent board with 4.0 Sqmm PVC unsheathed copper cable and 4.0 sqmm copper conductor cable as earth continuity conductor complete all as specified & directed. |
| 57 | S&F in repairs modular Socket, 6 Amp, 2/3 pin combined 2 module, complete all as specified and as directed. |
| 58 | S&F in repairs modular Socket, 6/16 Amp, 2/3 pin combined 2 module, complete all as specified and as directed. |
| 59 | S&F in repairs modular switch single pole, one way, 6 Amp, 1 module, complete all as specified and directed. |
| 60 | S&F in repairs modular switch single pole, one way, 16 Amp, 1 module, complete all as specified and directed. |
| 61 | S&F in repairs modular switch single pole, two way, 6 Amp, 1 module, complete all as specified and directed. |
| 62 | S&F in repairs Bell multi music type complete all as specified & directed. |
| 63 | S&F in repairs modular Bell push 6 Amp, single pole, 1 module complete all as specified and as directed. |
| 64 | S&F in repairs Modular step type fan regulator, 120W, 2 module, complete all as specified & directed. |
| 65 | M&L for earthing as in replacement complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with GI wire of size 4.0 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 66 | M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified & directed. |
| 67 | S&F power unit up to 25 Amps including sockets 25 Amps, 04 module box for mounting of power unit and including power socket complete as specified and directed power unit complete all as specified & directed. Make - Legrand\ Havells\Anchor or equivalent in make as approved by GE |
| 68 | Supplying, laying and testing XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall with supporting insulators/saddles etc for following size including taking down existing old U/S LT U/G cable complete all as specified & directed. |
| 69 | 50 Sq mm, 3.5 Core |
| 70 | 35 Sq mm, 3.5 Core |
| 71 | 25 Sq mm, 4 Core |
| 72 | 16 Sq mm, 4 Core |
| 73 | M&L for repairing / testing Ceiling fan 1200/1400 mm sweep including rewinding, bush, bearing and fan blade suitable for 240V, ISI marked, 50HZ with regulator complete with all accessories and connection as per manufacturer instruction complete all as specified & directed.Note-(i) Fans shall have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length (ii) Spare parts shall be measured and paid separately as supply only . |
| 74 | M&L for painting of ceiling fan of size 1200mm sweep with down rod upto 2.00 mtr long with two coats of synthetic enamel white paint including preparation old painted surface including writing of MES No with letters n exc 15cm height complete all as specified and as directed. |
| 75 | All as per BOQ Serial item No 39 above but 1400mm sweep complete all as specified and as directed. |
| 76 | Supply only capacitor of capacity 2.5/4 mfd complete all as specified and directed. |
| 77 | Supply only Gun Metal bush suitable for any type of fan complete all as specified and directed. |
| 78 | Supply only ball bearing of No. 6200/ 6201/ 6202/ 6203 complete all as specified and directed. |
| 79 | Taking down exhaust fan of any type, any make and any sweep for repairing, opening the body including blade, checking for repalcement of unserviceable spares,cleaning, oiling, greasing including replacement of unserviceable spare by new one, painting, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed.Note : New spare parts required shall be measured and paid seperately as 'Supply only\\" |
| 80 | Supply only Ball bearing 2001/ 2002/ 2003 for exhaust fans complete all as specified and as directed. |
| 81 | Supply only Metal bush bearing for exhaust fans complete all as specified and as directed. |
| 82 | S&F in repairs 2.5 mfd capacitor complete all as specified and as directed. |
| 83 | All as per BOQ serial item No 47 above but 3.5 mfd capacity complete all as specified and as directed. |
| 84 | Taking down cabin fan/wall mounted fan of any type, any make , by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position complete all as specified and as directed.Note : New spare parts required shall be measured and paid seperately as 'Supply only\\" |
| 85 | Supply only Ball bearing size 2601 quality for cabin fan/wall mounted fan complete all as specified and as directed. |
| 86 | Supply only Metal bush bearing for cabin fan/wall mounted fan complete all as specified and as directed. |
| 87 | S&F in repairs 16 amp, 3 pin plug top complete all as specified and as directed. |
| 88 | Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity 25/50 ltrs comprising of the following works complete all as specified & directed:(a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the entire satisfection of Engr-in-Charge(b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required.(c) Inspect overflaw and vent pipes and remove blockages (if any)(d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points(e) Check, maintain and re-fixing thermostat and re-adjust(f) Visual examination of of fusible plugs for its serviceability(g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution(h) Checking of indicator lamp for its serviceability(j) Re-assembling the geyser, re-installed and testing complete(Note: (i) Spare parts/components of geysers shall be measured and paid seperately as \\"supply only\\" (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.) |
| 89 | Supply only heating element, 2KW capapcity, AC 230 volts, pressed/screw/ triangular/ ceramic type, ISI marked complete all as specified and directed. |
| 90 | Supply only heating element, 1.5KW capapcity, AC 230 volts, pressed/ screw/triangular/ ceramic type, ISI marked complete all as specified and directed. |
| 91 | Supply only thermostate element type EST, 11/20 Amp 250 Volt ISI Marked complete all as specified & directed. |
| 92 | Supply only thermostate element type EST, 7/15 Amp 250 Volt ISI Marked complete all as specified & directed. |
| 93 | Supply only hot and cold flexible pipe, high pressure with both end brass adopter 18\\" long ISI marked complete all as specified & directed. |
| 94 | Supply only copper connection tubes for inlet/outlet connection PVC washer, benjo nuts and bolts etc. 450 mm long 3/8'' dia standard gauge complete all as specified & directed. |
| 95 | S&F split type bolt MS 12mm dia, 10cm long grouted with cement mortar suitable for fixing new geyser including making good to distrubed surface complete all as specified and as directed. |
| 96 | S&F in repairs for indicating lamp, 230 V, flush type, rectangular, red indicator suitalbe for water heaters complete all as specified and as directed. |
| 97 | Supply only porclain Heating Element ceramic type suitable for 2 KW geyser complete all as specified & directed. Please Enable Macros to View BoQ information |