| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 5 | Dismantaling of PCC block walling/ brickwork or stone/ boulder masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed. |
| 6 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, exceeding 10cm in width and incluing setting in cement mortar 1:4, complete all as specified and as directed. |
| 7 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 8 | Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed. |
| 9 | Plain cement concrete M-5(1:5:10), type E-2 (using 40mm graded crushed stone aggregate), as lean concrete in foundation, complete all as specified and as directed. |
| 10 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed. |
| 11 | Chequered cement concrete coloured tiles, pre-polished, size 300mmx300mmx25mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 20mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed. |
| 12 | Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates, including necessary form work, complete all as specified and as directed |
| 13 | Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless-steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless-steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and as directed.Makes: TATA Steel/ Steel Authority Of India Ltd/ JSW Steel/ Rashtriya Ispat Nigam Ltd./ Essar Steel India.Note: A BOO will be convene to determine the weight of sections. |
| 14 | Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed. |
| 15 | Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 16 | Preparation of new or previously untreated mild/ rolled steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed. |
| 17 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paintlime wash, complete all as specified and as directed. |
| 18 | Welding in repairs not exceeding 2.50cm in length for metal thickness not exceeding 6.0mm thick, complete all as specified and as directed. |
| 19 | Excavating in post holes (or similar holes) each not exceeding 0.50 Cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm. complete all as specified and as directed. |
| 20 | Surface dressing not exceeding 15Cm deep in any type of soil, complete all as specified and as directed. |
| 21 | Hardcore of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 22 | Plain cement concrete M-7.50(1:4:8), type D-1 (using 20mm graded crushed stone aggregate), nominal mix, 100mm thick, as in floors, finished even and rough without using extra cement, to receive floor finishes of any type, complete all as specified and as directed. |
| 23 | Amount of Schedule of credit of for Rs 1,09,150.00 shall be deducted from quoted amount. Please Enable Macros to View BoQ information |