| 1 | Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation etc in hard and dence soil & getting out for laying of cable, poles etc, complete all as specified and as directed by Engineerr-in-Charge. |
| 2 | Excavation in trenches, exc 1.5m wide & n.exc 3.00m in depth for foundation etc in hard and dence soil & getting out for laying of cable, poles etc, complete all as specified and as directed by Engineerr-in-Charge. |
| 3 | Returning filling in including spreading leveling watering & well ramming in layers n exc. 25cm Cum thick, complete all as specified and as directed by Engineerr-in-Charge. |
| 4 | Removing of surplus excavated soil to a distance n.exe 50 Mtr and depositing where directed at a level n.exe 1.5 mtr above the starting point, complete all as specified and as directed by Engineerr-in-Charge. |
| 5 | Material and labour for sand filling in trenches as in cushioning to under ground cable spreading, levelling and punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose complete all as specified and directed. |
| 6 | Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm all as specified and directed. |
| 7 | Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole all as specified and directed by Engr-in-Charge.( NOTE- Excavation & PCC will be measured and paid separately) |
| 8 | M&L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation, filling mass concrete including necessary form work. |
| 9 | M&L for PCC 1:3:6 type C 1 using 20 mm graded aggregate block masonry with solid block ,exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed. |
| 10 | Material and labour for cement concrete in foundation, filling and mass concrete type B2 1:2:4 with using 40 mm graded crushed stone aggregate as in foundation, filling mass concrete including necessary form work. |
| 11 | Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs, restretching of ACSR conductor to achieve proper sag and rewinding to the insulators using aluminium/ GI wire all as required at site or directed. Note:- Distance between two poles irrespective of distance and four no of lengths of conductor shall be considered as a single span. |
| 12 | Supply and fixing in replacement of Shackle Type polymer insulator including galvanised mild steel straps, washers insulator bolts, washers and nuts of height 100 mm, max dia 115 mm,section of straps 31x5 mm,dia of bolts 14 mm all as specified and directed by Engr-in-charge. |
| 13 | Supply and fixing in replacement of Pin insulator polymer white, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified. |
| 14 | Supply and fixing in replacement of loop Polymer insulator white small size with overall dimensions 65 x 90mm, clearance of hole 16mm for stay complete all as specified and/or dirercted by Engineer-in-Charge. |
| 15 | Supply and fixing in replacement of disc type poymar insulator 145 mm heigh and 255 mm dia ball and socket type, sink disc assemble with tension clamps for conductors working pressure 11000 volts grade complete all as specified and/or directed by Engineer-in-Charge |
| 16 | Dismantling of stay assembly complete of any size and type from exisiting site all as directed by Engr -in- Charge. |
| 17 | Disconnecting and taking out worn out jumpers / connectors of LT/HT over head line / DO fuse unit in substations of any size or any length after removing binding wire / connector and replacement with the new ACSR weasel conductor jumpers including PVC sleeve in colour coding R/Y/B of same size and length approx 1.5mtr including new binding wire/ connectors suitable for AB switch/DO fuse unit, including provision of conducting jelly all as specified & directed by Engr-In-charge. |
| 18 | M&L for Painting to exposed surfaces of LT Steel tubular pole with one coat of synthetic enamel paint of complete pole and up to 1 mtr height from ground level with 3 strip of yellow colour synthetic enamel paint and two strip of black synthetic paint including preparation of old painted surface, complete all as specified and directed by Engr-in charge. |
| 19 | Material and labour for rubbing the background and Using stensils reflected Stiker of letter height not more than 50mm Stiker having green background and white colour writing to indicate the street/security pole number all as complete all as specified in Engineer in Charge. |
| 20 | Repair of pole copping for LT Pole Plain cement concrete M-15 nominal mix, type B-1 using 20mm graded crushed stone aggregate as in coping of pole including necessary form work , complete all as specified. |
| 21 | Supply and lay XLPE insulalted, armoured heavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 4.0 core lalid in trenches or passing through pipes, ducts or fixed to walls/poles including taing down old unserviceable cable and cable covers complete all as specified and/or as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 22 | Supply and lay XLPE insulalted, armoured heavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 24 Sqmm 4.0 core lalid in trenches or passing through pipes, ducts or fixed to walls/poles including taing down old unserviceable cable and cable covers complete all as specified and/or as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 23 | Supply and lay XLPE insulalted, armoured heavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core lalid in trenches or passing through pipes, ducts or fixed to walls/poles including taing down old unserviceable cable and cable covers complete all as specified and/or as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 24 | Supply and lay XLPE insulalted, armoured heavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core lalid in trenches or passing through pipes, ducts or fixed to walls/poles including taing down old unserviceable cable and cable covers complete all as specified and/or as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 25 | Supply and lay XLPE insulalted, armoured heavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 185 Sqmm 3.5 core lalid in trenches or passing through pipes, ducts or fixed to walls/poles including taing down old unserviceable cable and cable covers complete all as specified and/or as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 26 | Supply and lay XLPE insulalted, armoured heavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 300 Sqmm 3.5 core lalid in trenches or passing through pipes, ducts or fixed to walls/poles including taing down old unserviceable cable and cable covers complete all as specified and/or as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective items. |
| 27 | Supply and fixing in replacement of GI tubing 50mm dia \\"light grade\\" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as directed. |
| 28 | Supply and fixing in replacement of GI tubing 80mm dia \\"light grade\\" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as directed. |
| 29 | Supply and fixing in replacement of ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etccomplete all as specified and directed by Engr-in-Charge. |
| 30 | Supply and fixing in replacement of galvanized steel wire 4mm dia for continuous earth wire complete all as specified and directed by Engr-in-Charge. |
| 31 | Supply and fixing in replacement of MCCB with magnetic short circuit and overload protection of capacity 100 Amps, 415 Volts, 50 Hz, 25 KA, four pole complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fixing in replacement MCCB 160 Amps, 25 KA, 415 Volts four pole adjustable thermal & fixed Magnetic setting type complete all as specified and/or directed by Engineer-in-Charge. |
| 33 | Supply and fixing in replacement MCCB 200 Amps, 25 KA, 415 Volts four pole adjustable thermal & fixed Magnetic setting type complete all as specified and/or directed by Engineer-in-Charge. |
| 34 | Supply and fixing in replacement MCCB 250 Amps, 25 KA, 415 Volts four pole adjustable thermal & fixed Magnetic setting type complete all as specified and/or directed by Engineer-in-Charge. |
| 35 | Supply and fixing in replacement MCCB 400 Amps, 36 KA, 415 Volts four pole adjustable thermal & fixed Magnetic setting type complete all as specified and/or directed by Engineer-in-Charge. |
| 36 | Supply and fixing in replacement MCCB 630 Amps, 36 KA, 415 Volts four pole adjustable thermal & fixed Magnetic setting type complete all as specified and/or directed by Engineer-in-Charge. |
| 37 | Supply and fixing in replacement of digital type voltmeter of size 96x96 sqmm, flush mounted type, model three phase, class 0.5, complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of digital type ampere meter, three phase, class 0.5 flush mounted case, complete all as specified and as directed. |
| 39 | Supply and fixing in replacement of lamp indicator, three phase, class 0.5 flush mounted case, complete all as specified and as directed. |
| 40 | Supply and fixing in replacement of selector Switch, three phase, class 0.5 flush mounted case, complete all as specified and as directed. |
| 41 | Supply and fixing in replacement of wall/floor mounted LT Bus bar Chamber of 200 Amps fabricated by using sheet steel (CRCA) of 1.6 mm thickness, epoxy powder coated and comprising of 04 Nos of aluminium bus bar complete all as specified and as directed by Engineer-in-Charge. |
| 42 | M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 32X6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 3 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and/or directed by Engineer-in-Charge. |
| 43 | Supply and fixing in replacement Off load changeover switch 1000 Amps, 4 pole in sheet metal enclosure, side /front handle operated ccomplete all as specified and as directed by Engineerr-in-Charge. |
| 44 | Supply and fixing in replacement Off load changeover switch 630 Amps, 4 pole in sheet metal enclosure, side /front handle operated complete all as specified and as directed by Engineerr-in-Charge. |
| 45 | Supply and fixing in replacement Off load changeover switch 200 Amps, 4 pole in sheet metal enclosure, side /front handle operated complete all as specified and as directed by Engineerr-in-Charge. |
| 46 | Supply and fixing in replacement Off load changeover switch 200 Amps, 4 pole in sheet metal enclosure, side /front handle operated complete all as specified and as directed by Engineerr-in-Charge. |
| 47 | Supply & fixing in Replacement of 1100 volts grade Heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed Solid conductor in service connections 6 Sqmm twin core flat/circular cable complete all as specified and as directed by Engineerr-in-Charge. |
| 48 | Supply & fixing in Replacement of 1100 volts grade Heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed Solid conductor in service connections 10 Sqmm twin core flat/circular cable complete all as specified and as directed by Engineerr-in-Charge. |
| 49 | Supply & fixing in Replacement of 1100 volts grade Heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed Solid conductor in service connections 16 Sqmm twin core flat/circular cable complete all as specified and as directed by Engineerr-in-Charge. |
| 50 | S&F danger notice plate for LT 20x15cm size made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red, colour and fixed with suitable MS clamps, bolts and nuts complete all as specified and as directed by Engineerr-in-Charge. |
| 51 | Cutting the existing PCC/ Road for passing of UG Cable in road crossing and making good the disturbed surface of road to its original specification complete all as specified and as directed by Engineerr-in-Charge. |
| 52 | Deduct Schedule of Credit of Rs (-) 91735.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |