| 1 | Construction of 2 MLD STP including Jungle Clearing, Site Levelling by Cutting and Filling by way of Survey Design, engineering, supply, construction, erection, hydraulic testing and commissioning of STP (including reuse pump station & Main Pump station MPS) The scope shall include all required detailed engineering design, supply, execution of civil works, erection of equipment, testing, and process commissioning necessary to deliver a fully functional and compliant STP system. This work encompasses all civil, structural, architectural, mechanical, electrical, instrumentation, and infrastructure components as listed S.NO 1.01 to 1.05 below. |
| 2 | I. Civil and Structural Works: Construction of all liquid-retaining Reinforced Cement Concrete (RCC) structures, including the Primary Treatment Unit (Receiving Screen Chamber, Screen Channel, Homogenization Tank), Equalization Tank, SBR Tank, Sludge Storage Tank, and Treated Water Tank. This is inclusive of all earthwork, formwork, reinforcement, hydrostatic testing, and protective internal linings etc complete item of work as per standard specification &tender. Special Condition of Contract (SCC) Design & Drawing Submitted by the Contractor& Approved by Competent Authority As directed by the Engineer in Charge. |
| 3 | II. Buildings and Support Facilities: Construction of the Admin Building (G+1, approx. 140 Sqm), incorporating the Electrical Panel Room, Generator Room, Blower Room, laboratory, and Office/Admi Room, complete with finishes and internal services. Provision and installation of a Porta Cabin for Security etc complete item of work as per standard specification &tender. Special condition of contract (SCC) Design & Drawing Submitted by the Contractor& Approved by Competent Authority As directed by the Engineer in Charge. |
| 4 | Ill. Electro-Mechanical (E&M) and Process Systems: Supply, installation, testing, and commissioning of all process equipment manually operated sluice gates, coarse and fine stainless-steel manual screens, motorised screw-type grit removal system, Belt conveyor, complete SBR system with fine bubble diffuser grid, SS304 decanter assembly with actuator, gear motor, VFD, PLC–SCADA automation system, turbo/screw-type air blowers with air distribution valves, NRVs and expansion bellows; Return Activated Sludge (RAS) pumps, Surplus Activated Sludge (SAS) pumps, thickener feed, digester feed and sludge mixing pumps with associated valves, fittings and headers; Combi thickener–centrifuge mechanism, agitator mixers, poly-electrolyte dosing pumps and dosing tank mixers; supernatant and dewatering pumps; mechanical handling systems including chain pulley and EOT cranes; MS and SS fabrication, D.I. specials and fittings; complete LT/HT electrical and instrumentation system comprising transformer yard, panels, cabling, earthing, servo stabilizer, DG Set , instrumentation and on-line Continuous Effluent monitoring system (OCEMS) ; along with HDPE piping network, elevated transformer platform, and all ancillary mechanical, electrical and control works necessary for complete, safe and functional operation of the STP as per specifications, drawings and standards, all complete in all respects. Special Condition of Contract (SCC) Design & Drawing Submitted by the Contractor& Approved by Competent Authority As directed by the Engineer in Charge. |
| 5 | IV. Cotreatment unit: Construction of cotreatment unit including construction of receiving chamber, screen channel, Homogeneous tank, Pumps valves, aeration system etc complete item of work as per standard specification &tender. Special condition of contract (SCC) Design & Drawing Submitted by the Contractor& Approved by Competent Authority As directed by the Engineer in Charge. |
| 6 | V. Infrastructure Facilities: Complete site development, including onsite infrastructure facilities (within the premises) yard lighting , CC Road 3.5m wide, construction of the peripheral Compound Wall with Chain Link Fencing and MS Gate, and offsite (linking) infrastructure facilities external electrification, necessary power connections, transformer, and metering Providing external water supply connection at STP, Approach road 5.5m wide with 1m shoulders on either side along with Rising Main for peak flow rate as per CPHEEO specifications/ Guidelines, with screen channel, including effluent disposal arrangement/clear water pump station & electrical substation incl transformer. The selection of sewage treatment plant criterion will be guided by the least life cycle cost and latest effluent discharge standard. The plant shall include the complete civil, mechanical, electrical and instrumentation components including on-line Continuous Effluent monitoring system (OCEMS) for Treated effluent at the site and shall ensure that the discharge standards as per design parameters are met as per proposed technology (all Civil, E&M and Instrumentation Components) including DG Set, electromagnetic flow meters (at Inlet &outlet), Servo Voltage stabilizer (AVR) of required capacities and scope of work and design shall be based on sound engineering and prevalent norms. All necessary infrastructure connected with STP shall have to be got designed and vetted from reputed Government Institute viz IIT Jammu /NIT Srinagar/Govt Engg College Jammu. The scope shall also include all taxes, lift and leads complete. STP will have SCADA system so that whole plant can be operated from control room & linked to all IPS at one point and all relevant information is available in control room at any given point. etc complete item of work as per standard specification &tender. Special Condition of Contract (SCC) Design & Drawing Submitted by the Contractor& Approved by Competent Authority As directed by the Engineer in Charge. |
| 7 | Earth work in bulk excavation by manual means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.c) All Kind of Soils for construction of collection well,RCC elevated Bridge,Manholes ,IPS-1&2 and pumproom- 1&2- 1&2 |
| 8 | Earth work in bulk excavation by manual means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.c) Ordinary Rock for construction of pumproom- 1&2- 1&2 and I&D structure |
| 9 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. for construction of pumproom- 1&2- 1&2,RCC elevated bridge for crossing & I&D structure |
| 10 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge for construction of I&D structures |
| 11 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.b) Hard Rock (Blasting Prohibited) for construction of pumproom- 1&2- 1&2 and RCC elevated bridge for crossing |
| 12 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.c) All Kind of Soils above 6.0meters for Construction of collection well,IPS-1&2,Manholes,pumproom- 1&2- 1&2,RCC elevated bridge for crossing. |
| 13 | Earth work in excavation by manual means in trenches for foundations , drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andmramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil for laying of conveying main and pumping main |
| 14 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil for laying of conveying main and pumping main |
| 15 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: Ordinary Rock for laying of conveying main and pumping main |
| 16 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :90% of EWE from 1.5 to 3.0 metres by Mechanical means for construction of Collection well,Manholes and IPS-1&2 |
| 17 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materialBeyond 1200 mm girth upto and including 2400 mm girth for construction of I&D structures |
| 18 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materialBeyond 300 mm girth upto and including 600 mm girth for construction of I&D structures |
| 19 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materialBeyond 600 mm girth upto and including 1200 mm girth for construction of I&D structures |
| 20 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge a)In cement mortar for construction of I&D structures |
| 21 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge for construction of I&D structures |
| 22 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete for construction of collection well,elevated RCC bridge for crossing,Manholes,I&D structure,IPS-1&2 and Generator sets |
| 23 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plaincement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge M-15 grade plain cement concrete (cement content considered @ 240 Kg/cum.) for construction of collection well,manholes and IPS-1&2 |
| 24 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)Footings,Pedastal,Foundation Base SlabWeir for construction of I&D structure,pumproom- 1&2- 1&2 and RCC elevated bridge for crossing |
| 25 | Providing and laying in position cement concrete of specified grade including curinexcluding the cost of centring and shuttering. All work upto plinth level with 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)For Thrust Block for conveying main |
| 26 | Providing and laying in position machine batched and machine mixed design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.Base Slab,Sidewalls,Floor Roof Slab,Beams for construction of collection well,Manholes and IPS-1 & 2. |
| 27 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).for construction of I&D and pumproom- 1&2- 1&2 |
| 28 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) for construction of IPS-1&2 and RCC elevated bridge for crossing |
| 29 | Providing and laying in position machine batched and machine mixed design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.30 mm red sand stone sun shade (chisel dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement : 4 coarse sand) including finishing and curing complete. for construction of collection well |
| 30 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)RCC M20 for Sun shades of 0.60M width, 75mm th. at fixed end and 50mm th. at free end for construction of pumproom- 1&2- 1&2 |
| 31 | Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation, footings, bases of columns etc. and mass concrete for construction of collection well,conveying main,RCC elevated bridge for crossing,manholes,I&D structure,IPS-1&2 and pumproom- 1&2- 1&2 |
| 32 | Extra for shuttering in circular work (20% of respective centering and Shuttering items) for construction of collection well,Manholes and IPS - 1&2 |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for:b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc for construction of collection well, manholes,I&D structure and IPS-1&2 |
| 34 | Extra for shuttering in circular work. Add 20% of the rate of respective item of centring and shuttering for construction of collection well,manholes & IPS-1&2 |
| 35 | Centring and shuttering including strutting, propping etc and removal of form work forc) Suspended floors, roofs, landings, balconies and access platforms for construction of collection well, manholes ,IPS-1 & 2 and RCC elevated bridge for crossing |
| 36 | Centring and shuttering including strutting, propping etc and removal of form work for e) Column, pillars, posts and struts etc construction of IPS-1&2 and RCC elevated bridge for crossing |
| 37 | Centring and shuttering including strutting, propping etc and removal of form work for c) Lintels, beams, girders, bressumers and cantilevers etc for construction of collection well,RCC elevated bridge and IPS-1&2 |
| 38 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth levelc)Thermo-Mechanically Treated bars of grade Fe-500D for construction of IPS-1&2,I&D structure,manholes,pumproom- 1&2,Collection well,RCC elevated bridge for crossing,generator sets |
| 39 | Carriage of materials by mechanical means transport including loading, unloading and stacking as directed upto a lead of 5km for disposal.By Mechanical Transport including loading, unloading and stacking for construction of manholes |
| 40 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing. including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design for construction of manholes |
| 41 | Circular shape 560mm internal diameter - HD - 20 for construction of manholes |
| 42 | Supply and Fixing in position of MS heavy structural steel including cost and conveyance of all material , labour charges for fabrication and fixing in postion etc,. Complete. For construction of collection well and IPS-1&2 |
| 43 | Provision for Chain Pulley for construction of IPS-1&2 |
| 44 | Coursed Rubble Masonry with hard stone in foundation and plinth and curing complete with:a) Cement mortar 1:6 (1 Cement : 6 coarse Sand) (1st Sort) for pumproom- 1&2 |
| 45 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) for construction of collection well |
| 46 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) for construction of pumproom- 1&2 |
| 47 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) for construction of pumproom- 1&2 |
| 48 | 6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand) for construction of pumproom- 1&2 |
| 49 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand) for construction of pumproom- 1&2 |
| 50 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall for construction of pumproom- 1&2 |
| 51 | 20mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand)Internal Plastering for Collection well upto 3.0m for construction of collection well |
| 52 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc completeb)On concrete work for construction of collection well |
| 53 | Colour washing such as green, blue or buff on new work (two or more coats) including abase coat of white washing with lime to give an even shade for construction of pumproom- 1&2 |
| 54 | Colour washing such as green, blue or buff on new work (two or more coats) including abase coat or white washing with whiting to give an even shade for construction of pumproom- 1&2 |
| 55 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work complete as per SS for construction of well |
| 56 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.c) 50 mm thick with 20mm nominal size stone aggregate for construction of pumproom- 1&2 |
| 57 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. a) 80x1.25 mm M.S. laths with 1.25 mm thick top cover for construction of pumproom- 1&2 |
| 58 | Providing and fixing factory made uPVC white colour sliding glazed windowabove 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gar with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.149E.1 a) Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.) for construction of pumproom- 1&2 |
| 59 | Providing and fixing double glazed hermetically sealed glazing in aluminum windows, ventilators and partition etc. with 6mm thick clear float glass both side having 12mm air gap including providing EPDM gasket, perforated aluminum spacers, desiccants, silicon sealant (both primary and secondary sealant) etc. as per specifications, drawings and directions of Engineer-in-charge complete for construction of collection well |
| 60 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters for construction of well |
| 61 | Providing precast cement concrete jali M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) reinforced with 1.6 mm dia mild steel wire including,roughening, cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand) etc complete upto floor two level excluding plastering of the jams, sills and soffits. a) 50 mm thick for construction of pumproom- 1&2 |
| 62 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m for construction of pumproom- 1&2 |
| 63 | Providing and installation of internal electrification in pump room -1 & 2 |
| 64 | Providing and fixing ball bearing for rolling shutters for collection well |
| 65 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksMS Flat for Anchoring for construction of RCC elevated bridge for crossing |
| 66 | Providing and laying S&S Centrifugally Ductile Iron Pipesconforming to IS : 8329 150 mm dia DI K9 pipe |
| 67 | Providing and laying S&S Centrifugally Ductile Iron Pipesconforming to IS : 8329 200 mm dia DI K9 pipe |
| 68 | Providing and laying S&S Centrifugally Ductile Iron Pipesconforming to IS : 8329 250 mm dia DI K9 pipe |
| 69 | Providing and laying S&S Centrifugally Ductile Iron Pipes conforming to IS : 8329 150 mm dia K7 pipe |
| 70 | Providing and laying S&S Centrifugally Ductile Iron Pipes conforming to IS : 8329 200 mm dia K7 pipe |
| 71 | Providing and laying S&S Centrifugally Cast Ductile Iron Pipes conforming to IS : 8329 250 mm dia K7 pipe |
| 72 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete250 mm dia. R.C.C. pipe |
| 73 | Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.300 mm dia. R.C.C. pipe |
| 74 | Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.450 mm dia. R.C.C. pipe |
| 75 | Providing and laying S&S Centrifugally Ductile Iron Pipes conforming to IS : 8329200 mm dia DI K9 pipe |
| 76 | Providing and laying S&S Centrifugally Ductile Iron Pipes conforming to IS : 8329300 mm dia DI K9 pipe |
| 77 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.150 mm dia DI K9 pipe |
| 78 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.200 mm dia DI K9 pipe |
| 79 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.250 mm dia DI K9 pipe |
| 80 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.150 mm dia K7 pipe |
| 81 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.200 mm dia K7 pipe |
| 82 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.250 mm dia K7 pipe |
| 83 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.200 mm dia DI K9 pipe |
| 84 | Providing push-on-joints to Centrifugally (Spun) Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.300 mm dia DI K9 pipe |
| 85 | Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS :9523:Total weight of ductile iron fittings - Up to 600mm dia |
| 86 | Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS :9523:Total weight of ductile iron fittings - above 600mm dia |
| 87 | SUBMERSIBLE SEWAGE NON-CLOG VERTICAL PUMPSupply, delivery, installation, testing and commissioning of Submersible sewage, Non clog vertical type pump suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, 1500 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations (4) all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer, arrangements for lifting for maintenance, guide pipes etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S. bearing, S.S shaft with sleeve, SS strainer & MS motor body, including compatible panel board consisting of Auto Transformer Starter suitable for local & remote pump control application consisting of Auto Transformer (vacuum impregnated, air cooled having three (3) tappings at 50%, 65% and 80%), incomer MCCB / MPCB, overload relay and contactors as per Type II coordination including digital MFM with RS 485 communication port, analogue type ammeter with selector switch, run hour meter, required protective relays & control accessories.STANDARD ACCESSORIESSupply, Delivery and Installation of Standard accessories including Power cable of PVC+Cu length 5mtrs, Pedestal auto rail coupling of Cast Iron(CI),Single Rail GR pipe of SS304 length 10Mtr and along with GRP coupler, Lifting chain with bow shackles and control panel including auto transformer starter Including Suction pipe dilavery pipe up to manifold sutuable Valves ,NRV,Pressure Gauge,Manifold etc. |
| 88 | Supply, Transportation, erection and commissioning (Excluding Foundation) of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of 5 KVA out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete without control panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, t to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. |
| 89 | B.Diesel Engine : Kirloskar / Cummins / Mahindra & Mahindra Diesel Engine start, developing suitable 6.25 BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standards |
| 90 | C. AMF Control Panel:- AMF control panel shall be fabricated with 16SWG CRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following.01. Voltmeter with selector switch.02. 4 Pole MCCB incomer of Suitable rating of Schenieder / L&T make for EB and DG.03. Ammeter with selector switch with CTs.04. PF Meter and frequency Meter.05. Indicator lamps (set Run, Load ON) with fuses.06. KWH Meter of required rating.07. Set of control fuses and current transformer.08. Input Terminal board and output Terminal Board.09. Battery charger with transformer rectifier unit.10. Alternator supply air break contactor of L&T make.11. Main supply air break contactor of L&T make.12. Audio Visual announciation.13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons.14.Control cable up to 15 Mtrs 2.5Sqmm 6 Core |
| 91 | Supply of 185 Sqmm of 3.5core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI /Finolex / Payal / RR kable / Beljin /Ollvin / Finecab / RPG / V - Guard / Orbit/ Fortune Arrt / Gemscab / Bonton / SPM/ Unistar / Windsor/Avocab / Pawancab/ Nakoda / Suncab for generator sets |
| 92 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: a) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) for construction of I&D structure,pumproom- 1&2,RCC elevated bridge for crossing,conveing main and generator sets |
| 93 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:b) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for generator sets |
| 94 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required for generator sets |
| 95 | Operation & Maintenance (O&M) for 5 Years Please Enable Macros to View BoQ information |
| 96 | Operation & Maintenance (O&M) for 5 Years Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail