| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6(1 cement : 6 coarse sand) |
| 3 | Providing and fixing Ist quality ceramic digital joint less glazed wall tiles of size not less than 300 x 400mm of approved make and shades as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 4 | Providing and laying Ist quality Ceramic glazed floor tiles of size 300x300 mm of approved make and shades laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 5 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting |
| 6 | on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. |
| 7 | Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity |
| 8 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 9 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 10 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like difusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 11 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 12 | 20 mm cement plaster of mix:1:6 (1 cement: 6 fine sand) |
| 13 | 12 mm cement plaster of mix:1:6 (1 cement: 6 coarse sand) |
| 14 | Providing and applying white cement based putty of average thickness 1 mm @ 6 kg per 10 sqm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 15 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 16 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 17 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 18 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 19 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 20 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 21 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 22 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 23 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.Internal work - Exposed on wall20 mm dia nominal bore |
| 24 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :20 to 50 mm nominal bore |
| 25 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 26 | 25 mm nominal bore |
| 27 | 20 mm dia |
| 28 | 65 mm nominal bore |
| 29 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 20 mm dia. nominal bore |
| 30 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 31 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 32 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level on the existing frmae (Excluding cost of frame)Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), lightreflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 33 | Providing and fixing white vitreous china flat back white vitreous china flat back urinal (Cera CASEY *##Cat. No. S4020101) with Urinal Valve Auto Closing System with Built-in Control Cock & Wall Flange (Jaquar PRS-077) with standard G.I. flush pipe and C.P. brass spreader including C.P. connecting pipe with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 34 | Providing and fixing of frosted/ Sun /tinted/ Crystal White designer Film 2 Mil thick film having pressure sensitive adhesive ,Total Thickness of film excluding liner is over 120 micron,of approved Design on the Mirror/ Glass or any other Surfaces as per approved design on glass with bubble free installation, no extra cost/liability to be paid for reapplying defective application if any bubble or irregularity is vissible within a few days of newly applied Sun Film as directed by and as per entire satisfaction of Engineer-in-charge . (The work includes the cost of Scaffolding, ladder or anyother support required at site upto 5 Meters of Heights only & includes cleaning of Glass/ mirror before applocation). (Glass Film Make Garware/Cosmo/Saint Gobain/ 3M) |
| 35 | Providing and Fixing Zebra/ Roller Blinds of Specification similar to Vista Sheer Dimout Blinds Hardware Specification Roller Tube: Made up of High Strength Anodized Aluminium Alloy Extruded grooved tube. Size:40mm outside diameter, weight = 220gms/running recontrol Unit with Clutch Mechanism: The control unit is made of high strength reinforced plastic. The clutch is of warp spring design. High carbon steel springs are provided to transmit motion from the driven mechanism Clutch is operated directionally by the use of beaded endless chain to raise and lower the blind smoothly to decide height. Idler: Idler is of high strength reinforced plastic, consisting of an outside sleeve and centre shaft. Sleeve provide bearing surface for centre shaft and rotate freely, providing smooth, quiet and long wearing operation. Round Type Bottom Rail: This is made up of high Strength aluminium alloy Extruded tube, White is powder coated in white. Size: 14mm outside dia.; weigh: =220gms/running mtr Triangle type Bottom Rail: This is made up of high Strength aluminium alloy Extruded tube, which s powder coated in white Size: 15x24x24mm; Weight 230 gms/running mtr. Valance Rail: This is aluminium Extruded Rail made up of High Strength aluminium alloy, which is Powder Coated in White. Size: 84.5 mm Width; weight 320gms/running mtr. Ceiling Rail: This is aluminium Extruded Rail made up of High Strength aluminium alloy, which is Powder Coated in White. Size: 75.6X12mm; weight= 480gms/running mtr. Installation Bracket: It is made up of mild steel with white powder coating having thickness of 1.8 mm.it is used for mounting control unit & idler. Ceiling Bracket: It is made up of mild steel with white powder coating having thickness of 1.0 mm. t issued to fix the blind to the wall or ceiling. Operating chain: This is made of 4.5 mm plastic beads molded on 2.0 mm thick polyester cord. The pitch of the beads is 6mm. The chain drives the sprocket fixed in the end control unit to close and open the blind. The pitch of the chain corresponds to the sprocket in perfect match for trouble free operation. End Cap: End cap for triangular bottom rail, round bottom rail, Ceiling rail and valance are made up of high strength molded plastic in white colour. |
| 36 | Fabric: Technical Data, FR Grade (NFPA 701 :2015) 100% polyester, Fabric width 280 cm, Weight 112 GSM +-5%Thickness 0.30 mm+_5%Fabric Repeat size Soild 7.5 cm +_ 5 % Mesh 5 CM +_ 5 %. |
| 37 | Add 0.5% for water charges |
| 38 | Credit material |
| 39 | Old urinal |
| 40 | Metal scrap Please Enable Macros to View BoQ information |