| 1 | Chipping of Existing damaged Pressed tiles including cost of removal and conveyance etc.., |
| 2 | Clean Removal of Existing Weathering Course over roof including cost of removal and conveyance etc.., |
| 3 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 4 | Damp Proof Course in Cement Mortar(1:3) 20mm Thick using 5% Crude Oil etc. Complete complying with standard specification and as directed by the Departmental Officers., |
| 5 | Chipping of Existing damaged Celing plastering including cost of removal and conveyance etc.., |
| 6 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 7 | Painting Old Plastered Wall Surface with One finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 8 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 9 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 10 | Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 11 | Supply and fixing of Electrical works including cost and conveyance of materials etc complete exhast fan 12 |
| 12 | exhast fan 9 |
| 13 | 22w led |
| 14 | 9w cfl |
| 15 | 5a plug |
| 16 | 4 elbow |
| 17 | 4 pipe |
| 18 | angle cork |
| 19 | 2 1/2 nani trap |
| 20 | light point |
| 21 | 36w SL light |
| 22 | wall mounted fan |
| 23 | UPVC DOOR Instalation |
| 24 | 2 X2 PVC Manhole Cover |
| 25 | ewc cover |
| 26 | 1.5 ton AC GAS service |
| 27 | furniture table |
| 28 | furniture chair |
| 29 | ladder |
| 30 | shoe rack |
| 31 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 32 | Supply delivery and fixing of RR Stone with necessary cement plastering and conveyance of all materials complete as per standard specfications and instructions given by departmental officers |
| 33 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 34 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 35 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 36 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 37 | Supplying and fixing Teakwood fully panelled (Single Leaf) shutters using Teakwood scantlings of size 100x40mm for styles & rails, 22mm thick planks for panels(5 Nos) and Brass Furniture fittings(3 Nos - Brass Hinges 125x30mm, 2 Nos - Brass Tower bolt 300x12mm, 1 Nos - Brass Tower bolt 200x12mm, 1 Nos - Brass Aldrop 250x16mm, 2 Nos - Brass Handle 200mm) including cost of wind appliances and labour charges for fixing the furniture fittings in position etc., complete complying with standard specification and as directed by the departmental officers |
| 38 | Supplying and Fixing of Doors - Framed and Planked Doors - Single Leaf 1350 X 2100mm Etc, Complete Complying With Standard Specification and as Directed by the Departmental officers. |
| 39 | Painting Old wood work with One coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 40 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) Please Enable Macros to View BoQ information |