| 1 | SUB HEAD -1 SITC of Cocealed split type AC |
| 2 | Supply & Delivery of Inverter Ducted/ Concealed split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 26.37 kw, minimum Air Flow 3000 CFM, with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better , both condenser and cooling coils made of copper tube connectingchord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi/ Voltas/Blue Star) |
| 3 | Supply & Delivery of Inverter Ducted/ Concealed split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 17.58 kw, minimum Air Flow 2000 CFM, with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better , both condenser and cooling coils made of copper tube connectingchord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi/ Voltas/Blue Star) |
| 4 | Supply & Delivery of Inverter Ducted/ Concealed split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 14.1 kw, minimum Air Flow 1460 CFM, with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better , both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi/ Voltas/Blue Star) |
| 5 | Installation, testing & commissioning of 4.0-7.5 ton AC machines complete with outdoor condensing unit on iron angle / powder coated bracket & indoor cooling unit on wall with suitable bracket . Rate is inclusive of cutting of wall for making holes and mending good the damages. |
| 6 | Supply and charging Refrigerant - R-32/R-410A/R407C |
| 7 | Supply & fixing of HVAC grade copper pipe with minimum thickness 9 mm Nitril Rubber insulation of following sizes for liquid line and gas line / suction line between ODU and IDU (Make - Ryoku/Nippon): |
| 8 | Supply and fixing of fire retardant nonporous double layer flexible connection Canvass connection for concealed split air-conditioners. |
| 9 | Suupy,laying and termination of following size PVC insulated PVC sheathed unarmoured copper Cable. (Make: polycab / finolex/KEI) |
| 10 | 4 core 4 sq.mm communication cable |
| 11 | Supply and fixing of Al powder coated continuous Grill(Make-Premier / Airkolkata) |
| 12 | Supply & laying PVC Drain Pipe 25mm dia(Make:Suprime/Oriplast) |
| 13 | Supply & laying PVC Drain Pipe 32mm dia(Make:Suprime/Oriplast) |
| 14 | Charges for Scaffolding arrangement including lifting for outdoor & indoor units |
| 15 | Supplying, fabrication & fixing of trap door made for maintenance of IDU of Air conditioning system by frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect as per direction of EIC. |
| 16 | Supplying & fixing of acoustic insulation inside indoor unit with 10mm thick open cell nitrile rubber (class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required |
| 17 | Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 8.5/11TR conceal split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½:3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm ineach platform in outer edge for transmitting the loadcentrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated with locking arrangement & shade arrangement above the grills with corrugated tin shade, necessary anti-rust painting as per direction of EIC. Area of the platform is3 Mtr x 1.2 Mtr |
| 18 | S & F iron cage (40\\"x 36\\"x24\\") structure for the split AC machine ODUs on wall for holding and provide protection with locking arrangement & shade arrangement above the grills with corrugated tin shade, necessary anti-rust painting as per direction of EIC |
| 19 | Supply & wiring with 3 core 2.5 Sq.mm XLPE Insulated, PVC tape innersheathed unarmoured copper cable. Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] (For Indoor Unit Connection) |
| 20 | Sub Head 2: Isolator/MCB/Timer DB/Enclosure |
| 21 | S & F 415V 40A Timer controller for Three phase twin control AC machine in SS double door in suitable SS enclosure with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 4x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :- |
| 22 | 10kA, C-Curve, 415V, 40A,FPMCB(LT/Schnider/ABB Elegance) as incomer --- 1 No. & 25A 3P MCB(LT / Schnider/ABB Elegance) as outgoing ----2 Nos |
| 23 | 24 Hr programmable Digital Timer (LT make cat no 67DDTO) ----1 No |
| 24 | 415V, 40A, 3 pole power contractor (LT make cat no MNX 32/230V/415V) with 1 NO +1 NC additional contact block ---- 2 sets |
| 25 | ON & OFF push button switch ----4 Nos |
| 26 | Overload (Range 9-14A) & SPP protection --------- 1 Set. |
| 27 | 20A Auto-Off-Bipass SPDT toggle switch (Approved /reputed make) ---- 2 Nos & 6A MCB for control circuit ---- - 3 Nos. |
| 28 | 10A SPST Moduler type switch (Make:- Legrand/ Myrius)-1 No |
| 29 | 70V-250V, LED Indicating Lamp (Make (Siemens) -------- 18 Nos |
| 30 | Outgoing connector make ELMAX (Approved/reputed make) - 1 No |
| 31 | S&F of 250V, 25A timer controlled single starter for controlling Single Air Conditioning Machines in SS double door 2+10 way DB enclosure (L&T |/ ABB / Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm2 copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl. necessary connections as per direction of EIC: |
| 32 | 25A DP MCB (L&T/ ABB / Legrand make) - 1 no. 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) - 1 no. 2-pole power contactor (L&T make Cat no MNX22 / 250V) -1 no. |
| 33 | 2-Modular AC motor starter (Legrand / Myrius Cat no 673031) -1 no. |
| 34 | 1-Module 10A Modular switch (Make Legrand / Myrius) - 1 no. 3-module plate with cover (Make Legrand / Myrius) - 1 no. 25A Auto-Off-Bipass SPDT toggle switch (approved reputed make) - 1 no. |
| 35 | LED indication lamp (approved reputed make) - 1 no. Outgoing bakelite connector 32A (Reputed make as approved by EIC) - 2 nos. |
| 36 | Sub Head 3: Supply & Laying of Cable & Wire |
| 37 | Supplying and Drawing 1.1KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of thefollowing sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as require. |
| 38 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 39 | 3x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC |
| 40 | Supply of 4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] [From Loop Box to Outdoor] |
| 41 | 4 Core 16 Sqmm |
| 42 | Laying of cable upto 3/4 core 25 sqmm on wall/surfacе incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy.mending good damages and painting |
| 43 | Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below:4 core 16 Sq. mm |
| 44 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials:4 core 16 Sq. mm |
| 45 | Supply & Fixing 3core 4Sqmm PVC insulated & PVC sheathed Multicore copper cable (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required from AC Starter to Outdoor unit.(Make:Finolex/KEI/Polycab) |
| 46 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 47 | 20mm size |
| 48 | 25mm size |
| 49 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 10 sqmm |
| 50 | 6 sqmm |
| 51 | 4 sqmm |
| 52 | 2.5 sqmm |
| 53 | SUB HEAD -4 SITC of split type AC |
| 54 | S&D of minimum High Wall inverter type Split Air Conditioner with R410A/R407C/R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (6.6KW-7.00 KW), Air flow rate (630-875) CFM, suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 15 A Plug Top (Make - Mitsubishi Electric/Daikin/O-General/Carrier/ LG/Panasonic/Johnson Controls (Hitachi)/Toshiba/Sharp/Mitsubishi Heavy/Voltas) |
| 55 | Supply and Installation of 5/8\\" & 1/4\\" copper refrigerant pipes with 9 mm thick rubber nitrile rubber insulation along with other accessories on the surface of wall. |
| 56 | Supply of XLPE Insulated & unarmoured stranded Copper Conductor control cables having following numbers of core for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] |
| 57 | 4 Core 2.5 Sqmm |
| 58 | Supplying and fixing MCB SS enclosure with IP-20/30protection, powder coated provision for two/four poleMCB, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. painting,connection & provision for earthing attachment |
| 59 | 4 Way |
| 60 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 61 | 32A FPMCB(Make- Legrand/ Siemens/ Schneider). |
| 62 | Supply & Fixing 240 V, 50 Hz, 1ph OLP 3+ starter with digital display for Split AC machine (1.5/2 Ton) having rated current 21 A Voltage range 160V-270V, IP 20, and provision to display voltage , current, and any fault indication (Make- Electron) incl. necessary connection on a S&F 3 modudule PVC Box (incl. supply material like wire, lugs etc if required) and commissioning the same. |
| 63 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. wall match colour painting of tray & MS support. [FOR AC Outdoor to Indoor pipe & communication cable laying] |
| 64 | 100x50x1.25mm (18SWG) |
| 65 | Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information |