Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling and removing of 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris 50m lead including stacking the useful materials for reuse and removing the debris with 50m lead including cost of all labour and T&P for the works etc. complete as directed by the Engineer-in-charge. |
| 2 | Providing and laying 4cm thick grading concrete cement concrete of required slope of mix 1:2:4 (1cement:2sand:4 graded stone aggregate of 12 mm nominal size) and down graded size black hard granite chips using 2% of eatwt proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge |
| 3 | Painting two coat with Plastic Emulsion Paint over a coat of primer to make in even finished surfaces in all floors and heights to wall surface oa pproved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.Ground Floor |
| 4 | First Floor |
| 5 | Second Floor |
| 6 | Head room |
| 7 | Providing fitting and fixing of false ceilling with Aluminium anodised T- section No.3215 with 2'-0\\" centre to centre, L-section No. 1705 upto micron on 4 walls to be fixed by means of steel screw and P.V.C. Plug and the Aluminium grid 2'-0\\" x 2'-0\\" with gypsum board suspended from celling with roll plug including cost, conveyance of all materials with labour and T&P required for the work etc. complete. etc complete as per specification & direction of Engineer-in-charge. |
| 8 | First Floor |
| 9 | Second Floor |
| 10 | Finishing wall surfaces with cement based putty (water based) of approved quality for making smooth even to receive painting including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.Ground Floor |
| 11 | First Floor |
| 12 | Second Floor |
| 13 | Head Room |
| 14 | Supplying, fitting & fixing of Granite tiles above 0.40 sqm (20mm thcik) for base plate of kitchen laid on 25 mm thick cement mortar (1:1) (1 cement : 1 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge.FIRST FLOOR |
| 15 | First Floor |
| 16 | Second Floor |
| 17 | Dismantling and removing of RCC Columns, beams, slab, staircase, landing, lintle etc including stacking the useful materials for reuse and removing the debris with 50m lead including cost of all labour and T&P for the works etc. complete as directed by the Engineer-in-charge. |
| 18 | Dismantling and removing of CB bricks/Stone masonary walls including stacking the useful materials for reuse and removing the debris with 50m lead including cost of all labour and T&P for the works etc. complete as directed by the Engineer-in-charge. |
| 19 | First Floor |
| 20 | Dismantling and removing of old lime or cement plaster from brick or stone masonery including stacking the useful materials for reuse and removing the debris with 50m lead including cost of all labour and T&P for the works etc. complete as directed by the Engineer-in-charge. |
| 21 | 16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.GROUND FLOOR |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Head Room |
| 25 | RCC work of M-20 grade in the Structural building works using 20mm to 10mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including all taxes in complete.GROUND FLOORFooting |
| 26 | Column |
| 27 | Plinth Beam |
| 28 | RCC work of M-20 grade in the Structural building works using 20mm to 10mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including all taxes in complete.Head RoomColumn |
| 29 | Roof Slab |
| 30 | Supplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-550) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works ( 4th revision) including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment)GROUND FLOOR |
| 31 | Second Floor |
| 32 | Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Vetrified floor tile of matt finish with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 25 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-chargeGROUND FLOOR |
| 33 | First Floor |
| 34 | Second Floor |
| 35 | In Flag post |
| 36 | Supplying, fitting & fixing of 8-10 mm thick and size of 600x600 mm vertified wall tile of in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. GROUND FLOOR |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge |
| 40 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 41 | Providing and fixing of 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with SS 304 Grade Matt Finished 3 Nos butt hinges of Size 100mm X 60mm X 2.5mm, 1 No 250mm X 16mm Aldrop,1 No 150mm x 16mm tower bolt,2 No 150mm length Door handle with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma/ equivelent make) |
| 42 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) ( FENESTA / NCL VEKA LTD./ PLASTO ONE Upvc Profiles Pvt LTD./ Equivelent make ) Three track sliding Window with top fixed 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for Three track sliding Window Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No. per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc. including cost and conveyance of all materials, accessories, labour charges,materials and product conforming to ASTM D 638 14,EN 477 95 and other applicable codes and standards.(W) etc complete as per direction of Engineer-in-Charge.(including Window Frame) |
| 43 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Ventilator Top Hung 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing deglazing at site etc. including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN 477 95 and other applicable codes and standards. (V) etc complete as per direction of Engineer in Charge.FIRST FLOOR |
| 44 | Supplying, fitting and fixing of M.S Grill gate ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) etc. complete in all respect as directed by the Engineer in charge.FIRST FLOOR |
| 45 | Supplying, fitting and fixing of M.S J Section ISMB 150 including cost and conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 46 | Painting two coat of Weather coat over a coat of primer of approved shade on new works to give an even shade over prepared surfaces including scuffolding to outside walls, including cost and conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.GROUND FLOOR |
| 47 | First Floor |
| 48 | Second Floor |
| 49 | Head room |
| 50 | Supplying, fitting and fixing of Wall panelling made out of 12mm thcik BWR ply and 4mm thcik of vernnier of approved brand including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. Ground FLOOR |
| 51 | First Floor |
| 52 | Fly ash brick masonry in cement mortar (1:4) using bricks of 23cm size having a crushing strength of not less than 75 kg per Sq.cm, after immersing Bricks for six hours in waters before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge. Ground Floor |
| 53 | Second Floor |
| 54 | Foundation and Plinth |
| 55 | 12 mm (1/2\\") thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- ChargeGROUND FLOOR |
| 56 | Head Floor |
| 57 | 6mm thick cement plaster (1:4) over RCC works including deep chipping, finished smooth with proper thickness, watering, curing for required days with cost, conveyance, royality, taxes of all materials and labour with T&P required or the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-charge.Head Room |
| 58 | Supplying, fitting and fixing of stainless steel of 304 grade in Hand railling using 50mm dia of 2 mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90Mtr. C/C and stain less square pipe bracing of size 32mmx32mmx2mm in rows in stair case as per approved design including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In- Charge.GROUND FLOOR |
| 59 | First Floor |
| 60 | Second Floor |
| 61 | head Floor |
| 62 | Providing, fixing retro-reflectorised, cautionary, mandatory & informatory sign as per IRC-67 made of high intensity gr. aluminium sheeting 1.5mm thick supported on MS circular pipe 65 NB firmly fixed to the ground by means of PCC M25 grade foundation of 45cm x 45cm x 60cm, 60cm below ground level as per drawing and Clause 801 of MoRT&H Specifications for Road & Bridge works etc. complete as per technical specification and direction of Engineer-in-Charge.90 cm equilateral triangle |
| 63 | 80x60 cm rectangular |
| 64 | 60 cm circular |
| 65 | Painting two coat with approved Synthetic enamel Paint on new iron work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.Ground Floor |
| 66 | First Floor |
| 67 | Second Floor |
| 68 | Head room |
| 69 | Providing fitting fixing of 100mm dia PVC rain water pipe with including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.Head Room |
| 70 | Earth work in foundation in hard soil or gravelly soil within 50m intial lead and lifts 1.5 M intial lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site including cost of all labour, T&P and dewatering if required for the work etc. complete as per drawing and Technical specification and as directed by the Engineer-in-Charge. |
| 71 | Earth work in Filling the foundation trenches and plinth with excavated materials with in initial lead of 50.00 mtr well etc complete complete as per drawing and Technical specification and as directed by the Engineer-in-Charge. |
| 72 | Supplying in Filling the foundation trenches and plinth with Sand well watered and rammed etc complete complete as per drawing and Technical specification and as directed by the Engineer-in-Charge. |
| 73 | Cement concrete of prop.(1:3:6) in foundation up to lowest bed level using hard black granite crusher broken metal of size 40 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6 thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc. complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 74 | Cement concrete of prop.(1:2:4) in foundation up to lowest bed level using hard black granite crusher broken metal of size 12 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6 thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 75 | Fly ash brick masonry in cement mortar (1:6) using bricks of 23cm size having a crushing strength of not less than 75 kg per Sq.cm, after immersing Bricks for six hours in waters before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge. |
| 76 | RCC work of M-20 grade in the Structural building works using 20mm to 10mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including all taxes in complete.Compound WallFooting |
| 77 | Column |
| 78 | Plinth Beam |
| 79 | Roof Slab |
| 80 | RCC M-20 in Bed |
| 81 | RCC M-20 in Wall |
| 82 | RCC M-20 in Cover Slab |
| 83 | Providing and laying 2.5cm thick grading concrete cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 4.7 mm nominal size) and down graded size black hard granite chips using 2% of eatwt proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge |
| 84 | Distempering two coat over a coat of primer to walls of approved shade on new works to give an even shade over prepared surfaces including scuffolding to outside walls, including cost and conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.Parking shed |
| 85 | Providing & laying of 80mm thick cement concrete interlocking paver block of m-40 grade and approved make variety colour and size made by block making machine with strong, vibratory compaction of approved design and shape , laid in required colour and pattern over 50mm thick including cost convayance royality labour with T&P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 86 | Construction of Granular sub-base by providing Close graded Granular sub-base Grading II materials as per table 400.2, spreading in uniform layers with Motor Grader on prepared surface, mixing by mix-in-place method with rotovator at OMC, and compacting with VRR to achieve the desired density complete as per clause 401 of MoRTH specification for Road and Bridge works (Latest revision) including cost, conveyance royalty and taxes of all material and labour with T&P required for the work etc. complete in all respect as per drawing and Tecnical Specification and as directed by the Engineer-in- Charge (measurement to be taken on finished compacted thickness under OMC compaction). |
| 87 | Providing Weep holes in brick masonary plain RCC abutment, wing wall, return wall with 100 mm dia AC pipes extending through full width of the structures with slop (1:20) etc complete including cost, conveyance royalty and taxes of all material and labour with T&P required for the work etc. complete in all respect as per drawing and Tecnical Specification and as directed by the Engineer-in- Charge. |
| 88 | EI WORKSINTERNAL ELECTRIFICATION:- Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. GROUP-A |
| 89 | GROUP-B |
| 90 | GROUP-C |
| 91 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 92 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( flame retradant type) with suitable size modular box & metallic cover plate (both side) flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 93 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 94 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 95 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable/KEI/Gloster/V-Guard) in recessed PVC FRLS conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar) of mentioned size as approved) as required as per direction of Engg.-in-Charge.. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic FRLS heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 96 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit. (2X2.5+1X1.5) |
| 97 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 98 | 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 99 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(2X6+1X2.5) |
| 100 | 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(4X10+2X6) |
| 101 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 102 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 103 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. |
| 104 | Supplying, installation, testing and commissioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air deliverygrater than 215m3/min Make- Crompton Energion Groove/ Havells Efficiencia Neo/ Usha Technix/ Bajaj Turbo Pro 12DC5) including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Eng.-in-Charge, . |
| 105 | S/F of Wall Mounted Fan including all accessories of USHA(Mist Air Icy Blue)/Crompton (Wall Mounted Fan-High Flo LG 18\\") /Equivalent make Havells/Orient/Bajaj of & connection as per direction of Engineer-in-charge. |
| 106 | S/F.of 600 mm high speed Ceiling Fan with fixing including all accessories of (Make- Havells/Crompton/Usha/Orient/Bajaj ) & connection as per direction of Engineer-in-charge. |
| 107 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 108 | Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 109 | SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 110 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 111 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 112 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.The luminaire should be Replacement Warranty will be 2 yearspanasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 113 | SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holder as required.The luminaire should be Replacement Warranty will be 2 yearspanasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 114 | Supply and fixing of 10 Watt LED BH Fitting.The luminaire should be Replacement Warranty will be 2 years (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro) |
| 115 | Supply,Installation,testing & commissioning of 90 W LED Street light having Aluminium die cast housing powder coated , UV stabilized PC IP lens diffuser, luminiere efficacy not less than 120 lumen/Watt,CCT-5700K,CRI-70,Lumen mainainance- 50000 burning hours as per L70B50, Power Factor > 95, THD<10% having constrant current,isolated, intigrated type driver with 4KV built in surge protection and 10 KV external,IP rating should be IP66,IK-07 protected .Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes . Cable entry thru cable gland in mounting pipe suitable up to 40-60 mm max OD. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 116 | Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 117 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 118 | Supply, delivery and fixing of Ceiling fan hook box made out of 18 swg GI sheet and containing 10 mm dia round ms bar projecting atleast 150mm on either side & duly bent to accommodate ceiling fan down rod bolt & having earthing arrangement as per direction of Engineer-in-charge. |
| 119 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door . |
| 120 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) |
| 121 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 122 | Supplying and fixing 25Amps rating,C series,10KA breaking capacity ,DP 240 volts, MCBof Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 123 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. ( For PDB) |
| 124 | Supplying and fixing 40Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. ( For LDB & Floor UPS DB) |
| 125 | Supplying and fixing 40A/63Amps 4P 415 volts RCCB 30 mA of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.( For PDB & LDB) |
| 126 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 127 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 128 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 129 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 130 | 630A MAIN CONTROL PANEL AT SERVICE AREA |
| 131 | 400A INDOOR LIGHT LOAD PANEL |
| 132 | 125A INDOOR FLOOR POWER PANEL |
| 133 | 100A INDOOR FLOOR LIGHT PANEL |
| 134 | 100A UPS PANEL Board |
| 135 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/Gloster/Finolex/RR Kabel) S/F of 10 sq.mm 4 Core ( For Highmast Light and street light) |
| 136 | S/F of 16 sq.mm 4 Core ( For feeder panel) |
| 137 | S/F of 70 sq.mm 3.5 Core( For Power load floor Panel, For Light Load floor Panel ) |
| 138 | S/F of 120 sq.mm 3.5 Core( For DG to Panel) 2 runs |
| 139 | S/F of 240 sq.mm 3.5 Core ( Main line) 2 runs |
| 140 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 141 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 185SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 142 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 143 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 144 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge 3.5 core x240 sq mm. |
| 145 | 4 core x10sq mm |
| 146 | 4 core x16sq mm |
| 147 | 3.5 core x70 sq mm |
| 148 | 3.5 core x120 sq mm |
| 149 | Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m) |
| 150 | S/F of Electrical safety acrylic chart/Poster depicted with various safety precautions , management and provides information to perform First Aid in case of electric shock etc in English and odia language with Multi color images and sign |
| 151 | EXTERNAL ELECTRIFICATION:- Supply,Installation,testing & commissioning of 90 W LED Street light having Aluminium die cast housing powder coated , UV stabilized PC IP lens diffuser, luminiere efficacy not less than 120 lumen/Watt,CCT-5700K,CRI-70,Lumen mainainance- 50000 burning hours as per L70B50, Power Factor > 95, THD<10% having constrant current,isolated, intigrated type driver with 4KV built in surge protection and 10 KV external,IP rating should be IP66,IK-07 protected .Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes . Cable entry thru cable gland in mounting pipe suitable up to 40-60 mm max OD. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 152 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 153 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 154 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 155 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 156 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 157 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 158 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 159 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/Finolex/Havells/Gloster/RR Kabel/V-Guard |
| 160 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 32mm |
| 161 | Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 200 km/hr wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts |
| 162 | SITC of LED type single dome aviation obstruction light. (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT/Valmont |
| 163 | SITC of 400W Outdoor Flood LED lights with silicon potted driver, IP66, , bottom opening maintanance , LPW not less than 130.Input Voltage: 85-265V AC ,Body : Die cast Aluminium, IP66 as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired. |
| 164 | SITC of 30W Flood light, with efficacy not less than 120 lm/W made up of pressure die cast housing with UV stabilized polycarbonate cover with integrated lens individual high powered LEDs with secondary optics ,IP65, IK 07 protection Make- Havells /Crompton/Phillips/Panasonic/LT/Bajaj including all accessories and connection as per E.I.C(inside temple) |
| 165 | SITC Of 15W LED SPIKE/BUSH focus LIGHT Environmental friendly, new generation, energy saving, decorative IP66 LED spike light using COB LED as light source.(inside temple) Make- Havells /Crompton/Phillips/Panasonic/LT/Bajaj |
| 166 | SITC Of 15W LED WALL DECORATIVE LIGHT Environmental friendly, new generation, energy saving, decorative IP66 LED spike light using COB LED as light source.(wall washer) Make- Havells /Crompton/Phillips/Panasonic/LT/Bajaj |
| 167 | SITC Of 10W UNECO TRACK/SPOT LIGHT Environmental friendly, new generation, energy saving, decorative with all accessories as per the direction of Engineer-in-charge. Make- Havells /Crompton/Phillips/Panasonic/LT/Bajaj |
| 168 | Suplying and Installation Of single color/MulticolorLED flexible strip light of 50 mtr with driver,IP-65.(for temple building) Make- Havells /Crompton/Phillips/Panasonic/LT/Bajaj |
| 169 | ELV SYSTEM:SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20digree to 70digreeC Cable support Conductor Resistance less than 9.38100m Max., Cable support Delay Skew: less than 45 ns/100m, Operating Voltage: 72V , Impedance: 100 pulu or minos 15 100 MHz. and Propagation Delay 250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 170 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 250Mhz & CAT6A 500Mhz. The information outlet connector shall be of gold/nickel, thickness of goldgraterthan 0.8 . The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 171 | SITC of Cat 6, 24 port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 172 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord (1 mtr) : 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 inch Gold Plated Contacts , 100percent Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit |
| 173 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord (2 mtr) : 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50inch Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit |
| 174 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 175 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19inch ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC PC Type ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 176 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : lessthan= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC graterthan equal to 45db, UPCgraterthan equal50db, APCgraterthan equal60db. Make Systimax Legrand Panduit |
| 177 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/Digisol/Netgear |
| 178 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 179 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 180 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 181 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV) 20 MM |
| 182 | 25 MM |
| 183 | (IP-PBX System) Supplying and fixing of Hybrid EPABX system equipped with 128 Analog extensions and 6 Analog Trunk, including required hardware and software etc as reqd. Make-Matrix/Siemens/Coral |
| 184 | Supplying desktop telephone sets with colour ID as reqd Make-Panasonic/Beetel |
| 185 | S/f of 50 pair MDF box with 3 nos. krone module. |
| 186 | S/f of 5O pair krone box with k2 no. krone module |
| 187 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 188 | 20 Pair |
| 189 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - |
| 190 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch |
| 191 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 192 | FIRE FIGHTING EQUIPEMENTS:- Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 193 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 194 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 195 | DG SET (160 KVA):- Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 160KVA ( Make -Kirloskar / Jakson/Mahindra) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years |
| 196 | UPS SYSTEM:- Supply ,installation ,testing & commissioning of 40KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 100AH, 40 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. |
| 197 | AUDIO VISUAL SYSTEM:- Supply of CAT5 Chairman Microphone Unit (Wired), OLED Screen.Note - These microphones connect to a PL- CSC Controller through Cabling for installation (to be procured Separately).Make-Peoplelink/Audiotechnica/Electrovoice |
| 198 | Supply of CAT5 Delegate Microphone Unit (Wired), OLED Screen. Note - These microphones connect to a PL-CSC Controller through Cabling for installation (to be procured Separately). Make-Peoplelink/Audiotechnica/Electrovoice |
| 199 | Supply of Conference System - Controller (Hybrid) is the full DSP Control Unit which supports Wired / Wireless or both in a Hybrid mode. The Controller works on High- fidelity sound quality by lossless audio transmission technology. Make-Peoplelink/Audiotechnica/Electrovoice |
| 200 | Supply of 8 Microphone inputs, 4 Line inputs, 1 wireless microphone input, 6 Line outputs and 1 USB echo suppression reference signal input/output interface and Dynamic adaptive noise reduction. No Micsincluded. Make-Peoplelink/Audiotechnica/Electrovoice |
| 201 | Supply of 2 handheld mic Set of UHF Frequency range Upto 50 meters (Line of Sight) operating frequency in the range of 40Hz to 18KhzMake-Peoplelink/Audiotechnica/Electrovoice |
| 202 | Supply of 200W Amplifier · 100*2 Watts Class D Mixer Amplifier with Bass, treble Equalizer· 2 Balance Phantom Microphone Inputs with two 3 pin phoenix connector· 1 Unbalanced Microphone Phono Input· RS232·Two line inputs with 3 pin phoenix·One line output with 3 pin phoenix·One recording output with 3 pin phoenix·Phantom powered switching between 48v to 12v·100*2 each channel phoenix connector speaker outputMake-Peoplelink/Audiotechnica/Electrovoice |
| 203 | Supply of Passive 5inch Wall mount Speakers Pair The PeopleLink High Performance Wall Mount Speaker is perfect for conference rooms, classrooms and auditoriums, featuring a 5.25 inch polypropylene woofer for deep, clear bass and a titanium dome tweeter for crisp highs. Its fully sealed, dustproof, and water resistant design ensures durability in any environment. The dual-axis mounting allows flexible vertical and horizontal placement. Whats in the box 2 speakers user manual, mounting hardware. Make-Peoplelink/Audiotechnica/Electrovoice |
| 204 | Supply of DISPLAY4K ULTRA HD (3,840 X 2,160), LGThinQAI,60Hz, AI Sound, a5 AI Processor 4k Gen7, Virtual 5.1 Up-mix.Make-LG/Samsung/Panasonic |
| 205 | SITC of All in One Desktop 24-CR0477IN PCi5-13th/8GB/512GB/W11/24\\".Make-HP/Dell |
| 206 | SITC of 16U Closed Shelf RackClosed Shelf Rack with Cantilever Shelves.Make- |
| 207 | SITC TV Cart Trolley with 75 Inches TV BracketTrolley cart for display with height ajustingand detachable wheels. |
| 208 | Supply of HDMI SPLITTER PORT 4K@30Hz-9360 |
| 209 | Supply and fixing of Audio Cable Coaxial Three Core with Socket |
| 210 | Supply and fixing of Optical Fiber HDMI Cable 8K 30 Meter Make- Hunter/ Impression |
| 211 | Supply and fixing of Optical Fiber HDMI Cable 8K 40 Meter Make- Hunter/ Impression |
| 212 | Supply and fixing of HDMI Cable 4K 05 Meter Make- Hunter/ Impression |
| 213 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20digree to +70digreeC Cable support Conductor Resistance lesee than 9.38 100m Max., Cable support Delay Skew: 45 ns/100m, Operating Voltage: 72V , Impedance: 100 15 100 MHz. and Propagation Delay 250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 214 | Testing , comissioning & Installation Charges with Transportation Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail