| 1 | 9mtr long 300kg PSC Pole |
| 2 | 7/10 SWG stay wire |
| 3 | Earthing device (coil support) |
| 4 | AB switch(11kv 400A) |
| 5 | HG fuse (11kv 400A) |
| 6 | Aluminium cable socket 300sqmm |
| 7 | MS Nuts & bolts with washer of Assorted size |
| 8 | Earthing (gi pipe) |
| 9 | Boundry wall metal separating with gate |
| 10 | LTDB with MCCB All. Bus bar of 3bay with kit kat fuse |
| 11 | 250KVA Transformer |
| 12 | Conductor AAA 100 Sq. mm. Insulated |
| 13 | Disc insulator (B&S) 70 KN Polymer |
| 14 | HW Fitting (B&S) 70 KN Polymer |
| 15 | 300mm 3.5C pvc cable |
| 16 | 11kv 3core 70mm2 XLPE cable |
| 17 | 11kv LA (11kv 5ka) |
| 18 | 100x50x6mm MS channel |
| 19 | 75x40x6mm MS channel |
| 20 | 50x50x6mm Angle |
| 21 | 50x6mm GI Flat for earthing, 2.36kg/mtr |
| 22 | Danger board |
| 23 | Red oxide paint |
| 24 | pin type insulator(polymer) |
| 25 | Plinth for transformer |
| 26 | concerting of pole |
| 27 | concerting of stay |
| 28 | Construction of earthing chamber |
| 29 | Couping ratio 1:1.5:3 of Pole |
| 30 | PG Clamp for Conductor AAA 100 Sq. mm. |
| 31 | Back clamp for anticlimbing device 25X3 |
| 32 | Cable termination kit for 3c 70 sqmm XLPE 11 KV cable indoor type |
| 33 | Cable termination kit for 3c 70 sqmm XLPE 11 KV cable outdoor type |
| 34 | WPB (GI) Pole 160 x 152 (11 mtr Long 30.4 kg per mtr) |
| 35 | 11 KV pin insulator polymer |
| 36 | Earthing of Support (Coil Type) |
| 37 | Top Channel 100 x 50 x 6 mm |
| 38 | Fish Plate 50 x 6 mm |
| 39 | Double Pole Belting Channel |
| 40 | 50 x 50 x 6 mm GI Bracing angle |
| 41 | Danger plate |
| 42 | Back Clamp for danger plate 25 x 3 mm |
| 43 | HT Stay Set |
| 44 | HT Stay insulator Type C |
| 45 | HT Stay Clamp |
| 46 | 7/10 SWG stay wire |
| 47 | GI Barbed wire anti climbing device |
| 48 | Back Clamp for anti climbing device 25 x 3 mm |
| 49 | GI Nut, Bolt & washer of different size |
| 50 | Black paint |
| 51 | Yellow colour paint |
| 52 | Stock, Storage, insurance |
| 53 | Tools & Plant |
| 54 | Transportation |
| 55 | Erection Charges (10% items) |
| 56 | Erection Charges (5% items) |
| 57 | Fixing of complete 11 V line Complete ST |
| 58 | Concreting ration 1:1.5:3 (500mm x 500 mm x 18) |
| 59 | Couping ratio 1:1.5:3 |
| 60 | 25 x 6 mm GI Flat for Earthing |
| 61 | 40 mm nominal bore GI pipe |
| 62 | LA (12 KV, 10 KA) station class |
| 63 | HDPE Pipe 8\\", 10 mtr, |
| 64 | 3c x 95 mm2 11 kV XLPE cable |
| 65 | Cable termination JT 3c x 95 mm2 11 kv XLPE cable indoor type |
| 66 | Cable termination JT 3c x 95 mm2 11 kv XLPE cable outdoor type |
| 67 | Stock, Storage, insurance under service connection |
| 68 | Tools & Plant under service connection |
| 69 | Transportation under service connection |
| 70 | Erection Charges (10% items) |
| 71 | Cubicla room for 11 KV |
| 72 | Excavation of Cable trench |
| 73 | Construction Earthing chamber including |
| 74 | Lay-11KV Cbl (70-400 sqmm) trench/Tray Please Enable Macros to View BoQ information |