| 1 | Civil Works |
| 2 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 3 | 50.6.7.1Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc. |
| 4 | 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 5 | 13.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 6 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 7 | 5.1.3Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 8 | 4.1.6Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 9 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 10 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 11 | 17.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 12 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | 11.41.3Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 800x 800 mm |
| 14 | 17.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. |
| 15 | 11.20.4Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment |
| 16 | 17.10.2.3Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink without drain board470x420 mm bowl depth 178 mm |
| 17 | 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 18 | 13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 19 | 10.25.2Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works |
| 20 | 50.2.25.1Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge |
| 21 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 22 | 50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 23 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 24 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge. |
| 25 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 26 | 51.19.ST4Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately)<br> 4. 35 to 50 flush capacity |
| 27 | 2.28.1Surface dressing of the ground including removing vegetation and in-equalities notexceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5m.All kinds of soil |
| 28 | 16.68Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour andpattern over and including 50 mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 29 | OD299005/2025-2026Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length up to 12 meteror as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 30 | OD298992/2025-2026Carpet Planet Artificial Grass - High Density Grass (Green 3-Tone)- Use As BalconyGarden, Carpet, Door Mat.Artificial Grass Carpet, Mat for Balcony, Lawnmat, Floor mat, Doormat, Mat forTerrace, Garden mats with 4 layers Protection (6.5x2 feet), Green Home Furnishing |
| 31 | OD298717/2025-2026Alphabet and Number Treewith a Set of Capital, Small and Numbers Apples |
| 32 | OD298718/2025-2026Slide for Kids | Safe and Fun Indoor and Outdoor Toy for Boys and Girls 2-4Years,06L x 55.9W x 74.9H CentimetersWebby Foldable Slide for kids | safe and fun outdoor and indoor Toy for boys andgirls |
| 33 | OD298719/2025-2026Play Nation Jumbo Brix Stack & Fix set| Infant & Preschool ToysJumbo Toy Building Blocks Set Multicolour |
| 34 | OD298720/2025-2026Toy Design See Saw - Multicolor |
| 35 | OD298721/2025-2026Samsung/LG/Godrej 180 L 2 Star Advanced Cappillary Technology with JumboVegetable Tray Direct cool Single door Refrigerator |
| 36 | OD298722/2025-2026Toshiba /Panasonic/LG or other available brand 42 inch (106 cm) Led Full HD TV1080 p |
| 37 | OD298723/2025-2026LG/O general/Samsung/Blue Star/Voltas/ available other brand 3 Star (2.0) Split AC-2025 ModelEqual series 2.0 Ton 5/4/3 Star Inverter Split Smart AC with Double swing automatic 3D air flow copper condenser |
| 38 | OD298724/2025-2026Supplying HW185-HW SD table 90*60*75cm (planks) |
| 39 | OD298725/2025-2026HW1860-HARDWOOD CONFERENCE HALL ARM CHAIR WITH CUSHION45/100*50*55CM |
| 40 | OD298726/2025-2026supply 12 mm thick EVA technology mat (kids playing mat)as per specifications.Interlock type size of 60*60 cm 400sqm*3 |
| 41 | OD298729/2025-2026PRT 1-FIBER BABY CHAIR HEAVY QUALITY |
| 42 | OD298730/2025-2026CLASS ROOM WALL THEME BASED ART ONE SIDE DRAW ANDINCLUDINGNUMBERS,ALPHABETS(ENGLISH,MALAYALAM),ONE SIDE GO BASEDARTWORK,CLASS ROOM( ACTUAL BILL ATTACHED DURING EXECUTION)BOTTOM 4 WALL GRASS,TREE ART AND NATURAL THEME ART ETC.4WALL TOPART CLOUDS,BIRDS,MOUNTAINS,ETC.AND INCLUDING DOOR ANDWINDOWPAINTING |
| 43 | OD299059/2025-2026PRT-MOON TABLE,FIBER MATERIAL SIZE 54*30*20 HEAVY QUALITY |
| 44 | OD298731/2025-2026Supplying of High Quality Magazine/book shelf |
| 45 | OD298732/2025-2026ZEBRA Blind for Windows Dual Layer Zebra Roller Shades Light Filtering SheerWindowTreatments Privacy Light Control for Day and Night Lightweight fabric to allowmaximumlight diffusion. Excellent UV protection, insulation and energy savings. Fabric treatedto resiststains and minimize dust built up. |
| 46 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 47 | OD298734/2025-2026Supplying and providing 304 grade Stainless Steel lettering for name board, fixing tothe wall with necessary fittings and other arrangements including cost andconveyance of allmaterial |
| 48 | OD299019/2025-2026Providing and fixing Granite of any colour and shade for Name board, of requiredsize laid over base of cement mortar 1:4 ( 1 cement : 4 coarse sand), including allcharges etc. complete at all, levels, including lettering & fixing |
| 49 | Electrical Works |
| 50 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 51 | 1.2Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed steel conduit, 2 way piano typeswitch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 52 | 90.2.1.1Supply and wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mmFRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWGbare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. All the terminationsin the switch boards and DB's shall be tinned and the wires shall be drawn andfixed along the periphery of the box using suitable ties, tie mounts etc as required.(RoHS compliant modular accessories).Single Control light point with 6A, plateceiling rose - Short point |
| 53 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). |
| 54 | OD298747/2025-2026Cost of 9W LED bulb |
| 55 | OD299141/2025-2026Supply and installation of 1200mm, 20W LED tubelight with all accessories asrequired. (Make: Crompton/Philips/Wipro) |
| 56 | 90.3.20.3Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 1X20W LED Lamp with box type fixture |
| 57 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required |
| 58 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 59 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. asrequired. |
| 60 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 61 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 62 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 63 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 64 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 65 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator |
| 66 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 67 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet |
| 68 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 69 | 2.11Supplying and fixing single pole blanking plate in the existing MCB DB completeetc. as required. |
| 70 | 2.17Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts "C" curve TP MCB complete with connections,testing and commissioning etc. as required. |
| 71 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 72 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 73 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 74 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 75 | 1.28.4Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module |
| 76 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 77 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm |
| 78 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm |
| 79 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 80 | 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG) |
| 81 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required20 mm |
| 82 | OD298981/2025-2026Supply & installation of 1 Phase Meter Board made from CRCA sheet complete withall accessories including 32A Cutout fuse, 32A DP MCB and to fix KSEB meters, etcas required including fixing it on wall, making good the damages colour washing etc.as required |
| 83 | 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 84 | Connection charges - KSEB |
| 85 | EXCLUSIVE OF GST |
| 86 | Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL |
| 87 | 2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items |
| 88 | 3.Rate should be Exclusive of GST. |
| 89 | 4.Work should be executed as per DSR/PWD specification and direction of Engineer at site. |
| 90 | 5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 91 | 6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 92 | 7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference. |
| 93 | 8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.) |
| 94 | 9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered) |
| 95 | 10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS. |
| 96 | 11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately. |
| 97 | Make of Electrical equipments/materials |
| 98 | All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification |
| 99 | Panel Boards: CPRI certified reputed manufacturers make |
| 100 | MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent |
| 101 | Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD |
| 102 | Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent |
| 103 | Cable Glands & Sockets - REPUTED MAKE , Cosmos |
| 104 | Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent |
| 105 | Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj |
| 106 | 12. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference. |
| 107 | 13.DELUXE MULTI SURFACE PAINT SYSTEM: Make: JOTUN, Asian, Berger, Nerolas or eq. in the order of pref. |
| 108 | 14.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client |
| 109 | 15.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO |
| 110 | 16. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref. Please Enable Macros to View BoQ information |