| 1 | Maintenance of Building |
| 2 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 3 | 13.98.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work |
| 4 | 13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 5 | 13.112.2:Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shadeOld work (one or more coats applied @ 0.83 ltr/10 sqm). |
| 6 | 15.57:Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge |
| 7 | OD512961/2025-2026:Providing and fixing in wall lining with Factory made single extruded WPC (Wood Polymer Composite) solid plain white colored board of 12 mm thick laminated with pvc foil of minimum thickness of 14 microns of approved designwith necessary fixing arrangement and screws etc. complete.12 mm thick. (Modified 9.158) |
| 8 | 12.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 9 | OD513319/2025-2026:Providing and fixing false ceiling at all heights with integral densified calcium silicatereinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approvedtexture, design and patterns in true horizontal level suspended on interlocking metal T-Grid ofhot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqmincluding both sides) comprising of main- T runners of size 24x38 mm of length 3000 mm andsecondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size600 x 600 mm, suspended from ceiling using galvanised mild steel items (L-shape level adjusterof size 24x10x0.50mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mmcenter to center and 40 mm long dry wall S.S screws. The work shall be carried out as perspecifications, drawing and as per directions of the Engineer-in-Charge.With 8 mm thick tegular edged light weight calcium silicate false ceiling tiles.(Modifieddata_26.22.1) |
| 10 | OD513013/2025-2026:Providing & fixing in position Factory made HDF (High-Density Fiberboard) laminate flooring with planks of sizes 1200mm length (minimum), 180 mm wide(minimum) and 8mm thick or nearest size in approved colour, texture and finish. The flooring shall be fixed with tongue and groove interlocking system, over 0.2mm polythene sheet as vapour barrier and 2mm EPE foam sheet, etc. all complete as per direction of the Engineer in-charge. |
| 11 | 11.41.4:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm |
| 12 | OD513019/2025-2026:Plywood partition with laminate finish :Providing and fixing plywood partition system as per approved drawing .Partition Frameworkfinished with 19 mm thick plywood , i.e. 50 mm sections to fixed at 600 mm c-c spacing/as persite condition. Both sides of the frame to be fixed with 9 mm plywood. Finish both side of thepartition with 1 mm thick laminate sheet fixed on the plywood using suitable adhesive .Finishthe partition with necessary grooves, electrical / window openings if any. Including cost andconveyance charges of all materials, labour charges etc |
| 13 | OD513033/2025-2026:Toughened Glass Partition with patch fittings :Providing and fixing 12mm thick Toughened glass Partition System with SS Patch Fittings asper design intent. Including all cost and conveyance of materials, labour etc complete. |
| 14 | 50.9.12.1:Providing and fixing Thomson Multi wood board or equivalent make, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately) as per the direction of site Engineer-in-charge. |
| 15 | 9.127.2:Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick |
| 16 | 9.115:providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer -in-charge. |
| 17 | 9.165.1:Providing and fixing bright /matt finished Stainless Steel handles of approvedquality & make with necessary screws etc all complete.125 mm |
| 18 | 9.79.1:Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40 mm |
| 19 | OD513310/2025-2026:Providing and fixing Automatic & Self Closing Hinge For Kitchen & Office Cabinet OrCupboard with mounting plate,necessary screws etc. complete as per directions of Engineer -in-charge: Inside Fitting |
| 20 | 24.3:Cleaning the sand stone surface and removing dirt, dust , bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by Archaeological Survey of India / Engineer - in-charge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building / structure, all as per direction of Engineer- in- Charge ( The rate is inclusive of all materials & labours involved except scaffolding). Please Enable Macros to View BoQ information |