|
| 1 | Well Construction |
| 2 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | OD499336/2025-2026:Extra for open well excavation for all class of soil for first depth |
| 4 | OD499337/2025-2026:Extra for open well excavation in all class of soil for second depth. |
| 5 | OD499335/2025-2026:Extra for open well excavation in all class of soil for third depth |
| 6 | OD500083/2025-2026:Sinking well in all soils other than rock to lines and levels and plumb by scooping out frominside and below the stiening including the use of dredgers or any other appliance,hire andlabour for kentledge,jetting,dewatering,blasting,vibrating or any other method includingremoval of obstacles and dumping the soil within a distance of 150m-Well 4.00m to 5.50mouter dia-1st depth upto 3m below spring level(Std PWD Data 1965 SI NO701 |
| 7 | 5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) derived from natural sources derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources derived from natural sources) |
| 8 | 5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining |
| 9 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 10 | 50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. |
| 11 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 12 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 13 | 50.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete |
| 14 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 15 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 16 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 17 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 18 | 10.5.2:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece |
| 19 | 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 20 | 10.25.1:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 21 | OD501159/2025-2026:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitchofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthicknesswith zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should haveprotective guard film of 25 microns minimum to avoid scratchesduring transportation andshould be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheetshall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal,complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins,rafters and trusses and including cutting tosize and shape wherever required. |
| 22 | OD500185/2025-2026:Excavating trenches of required width for pipes, cables, etc. including excavation for socketsand dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out theexcavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth,including consolidating each deposited layer by ramming, watering, etc. and disposing ofsurplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc., not exceeding 80 mm dia. |
| 23 | OD501167/2025-2026:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement &testing of joints complete as per direction of Engineer in Charge. 63 mm dia10Kgf/cm2(Modified 50.18.9.7.1 Without trenching and Refilling) |
| 24 | OD501621/2025-2026:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement& testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 |
| 25 | OD501684/2025-2026:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement& testing of joints complete as per direction of Engineer in Charge. 25 mm dia10KGF/cm2(Modified 50.18.9.3.2 Without Trenching and Refilling) |
| 26 | OD501626/2025-2026:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50mm dia Bend |
| 27 | OD509476/2025-2026:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -25mm dia Bend modi.50.18.9.20.4 Please Enable Macros to View BoQ information |