| 1 | Comprehensive maintenance of wall top perimeter electrical power fence 1.2 Mtr height with12 HT wire divided into 3 Zones and 3.2 Meter height with 30 HT wire divided into 01 Zones make of A1 fence including network fence controller software complete and make system fully functioning condition in installed at DCN palam complete all as directed by Engr-in-charge The details of the equipment /system to be included in the AMC are as under.(a) 12 HT electric power fence with connected accessories ( make- A1 fence) - 470 RM(b) 30 HT electric power fence with connected accessories ( make- A1 fence) - 140 RM(c) Nework fence controller and keypad and perimeter control - 04 Nos software complete. ( make- A1 fence) (d) SM OFC 12 Core ( Make - Diglink) - 600 RM(e) work station with 21\\" LCD TV monitor along with software ( Make -DELL) - 01 No |
| 2 | Notes:-(i) The comprehensive maintenance shall be done throuhg OEMs i.e Altima Security Technologies /A1 Fence /Static System (ii) The contract included for repair/ replacement and maintenance of Network electrical power fence complete i.e fence wire, OFC cable, pole, software and hardware controller ,insulator, LCD monitoring display, Enerzier, elctrical panel and connected all accessories of electric power fence, etc under comprehensive AMC.(iii) Quality of spares: The equipment ( Newrork for electric power fence and controller device) parts replaced must be new and equivalent in performance of existing part. (iv) The above maintenance include complete maintenance of existing electrical power fence system by regularly and systematically examining as required for smooth and efficient functioning of the equipment. (v) On each visit of the maintenance staff, a certificate to the effect will be co-signed by the user and Engineer-in-charge for verifying the visit. (vi) Monthly preventive maintenance visit will be comprise a team of an Engineer/ Technician, and also visit shall be made as and when required basis.(vii) Contractor will carry out comprehensive maintenance once in a month for Eleven (11) months and maintain the record of same as per the performa of monthly maintenance check enclosed in the tender documents.The same shall be forwarded alongwith RAR failing which no payment shall be released to the contractor(viii) Any repair/replacement of equipment part will be replenished without adding any cost to departmant except modification /Upgradation of hardware/software of equipment and civil work. |
| 3 | Comprehensive maintenance for IP Based Network CCTV Camera with their accessories in installed at DCN Palam complete all as directed by Engr-in-charge The details of the IP Network CCTV camera and their accessories to be included in the AMC are as under:-(a) High Speed outdoor IP Camera PTZ ( Make of CP Plus) - 06 Nos(b) HD outdoor/indoor IP Camera (fixed) ( Make of CP Plus) - 26 Nos(c) CCTV Software for server with 36 camera ( Make of CP Plus) - 01 Lot(d) Speed dome controller /PTZ controller( make of CP Plus) - 01 No (e) 12 core SM OFC cable - 600 RM(f) Layer 3/2 Switches with accessories ( Make of HP,Comnet) - 11 No(g) 24 Port light guide interconnect Unit , LIU (make of Diglink) - 02 No(h) 04 port controller server ( make of Barco) - 01 No(i) 42\\" LED TV Full HD for monitoring with CPU ( make of LG) - 02 No(j) 2 x2 LED 55' LED video wall 4 screen with controller ( make of BARCO) - 01 No(k) 5 KVA online UPS complete with backup (make of Emerson) - 01 No |
| 4 | Notes:- (Including in AMC)(i) All the items which are mentioned in the item No 2 should be covered under the AMC for 11 Months with OEM(ii) Repair ,maintenance of the total Hardware and software maintenance and troubleshooting for CCTV i.e Camera Visibility Test, DVR / NVR Recording Test, DVR / NVR Settings,controller server,keypad, Verification, and Disk Error Check, LED display monitoring complete part of Network of CCTV camera . Replacement of CCTV parts, and some consumable items and the maximum repair to the defective component of CCTV camera and their part are covered under AMC. (iii) In case of any technical snag it should be attended within 24 hours and ensure attending the break down calls on urgent basis. (iv) Monthly preventive maintenance visit will be comprise a team of an Engineer/ Technician, and also visit shall be made as and when required basis.(v) Contractor will carry out comprehensive maintenance once in a month for Eleven (11) months and maintain the record of same as per the performa of monthly maintenance check enclosed in the tender documents.The same shall be forwarded alongwith RAR failing which no payment shall be released to the contractor.(vi) The comprehensive maintenance in respect of IP based Network CCTV camera under his contract shall be done through OEMs or any authorised dealers i.e any one of M/s mobotix / m/s Bosch / M/s Barco /M/s diglink / M/s Synolgy / M/s LG/ M/s Hik-Vision / M/s CP Plus(vii) The equipment like replacement of CCTV Camera, NVR,VMS Software & hardware controller, electrical control panel , LED TV,video wall ,LAYER switches ,Hard disk, UTP & OFC cable , MCB will be paid separately. |
| 5 | Supply and fixing MCB DP 10 Amp ,10KA, 230 volt incluing PVC box mounting complete all as specified & directed. Make- L&T/Legrand/ Havells /Indo Asian/Siemens |
| 6 | Supply and fixing in replacement of high speed IP outoor PTZ Camera 2MP with metal body and and designed to capature high quality colour image inlow-light environments ,1/2.8\\" progressive Scan CMOS,upto 05 faces capture at the same time,min illumination- clour 0.005 lux@(F1.6 AGC ON), 25x optical zoom, 16X digital zoom complete all mounting /installation accessories ,fitting as per existing location complete all as specified and directed. Make:- BOSCH/HikVision/Panasonic/Bajaj/Honeywell /CP Plus |
| 7 | Supply and fixing in replacement of High speed 2MP smart IP Outdoor bullet Camera (fixed) with metal body and designed to capature high quality colour image inlow-light environments and support full HD,highframe rate resolution upto 60 fps., water and dust resistenance (IP 67) ,1/2.7\\"progressive Scan CMOS, Day & Night auto IR Cut filter with auto switch , min illumination 0.01 Lux @(F2.0 AGC ON),0 Lux with IR, Aperture-F2.0 complete. mounting /installation accessories , fitting as per existing location complete all as specified and directed. Make:-Panasonic/Bajaj /Honeywell / CP Plus |
| 8 | Supply and fixing in replacement of High speed 2MP smart IP Indoor bullet Camera (fixed) with Metal body and designed to capature high quality colour image inlow-light environments and support full HD,highframe rate,1/2.8\\"progressive Scan CMOS, Day & Night auto IR Cut filter with auto switch , protaction rating IP-66 , H.264/MJPEG Type, min illumination 0.01 Lux @(F1.2 AGC ON),0.028 Lux Aperture-F2.0 complete mounting /installation accessories , fitting as per existing location complete all as specified and directed. Make:- Panasonic/Bajaj /Honeywell / CP Plus |
| 9 | Supply and fixing in replacement of defective 4TB My Passport Portable External Hard drive, Black with automatic backup, 256 Bit complete all as specified and directed.Make-Seagate/WD |
| 10 | Supply and fixing in replacement of 12 Core SM optic Fibre Communication cable with the required termination to all point of camera loaction as per site requiremt complete all as specified and directed. Make:- Diglink/Usha Martin/finolex |
| 11 | Supply and fixing in replacement of armoured UTP cat 6 cable incuding clamp for fixing on wall /roof/ceiling etc complete as per site requiremt all as specified and directed. Make:- Diglink/Finolex/D-Link |
| 12 | Supply and fixing in replacement of UPS Battery 12V 36 AH sealed maintenance free battery complete all as specified and directed. Make Exide/Okaya/Microtek/Amron |
| 13 | Supply and fixing in replacement Managed Ethernet Switch with (8) 10/100TX + (2) 10/100/1000TX / 1000FX RJ45 or 1000 FX SFP Ports as per Model No CNGE2FE8MSPOE Complete mounting as per existing place all as specified and directed .Make - Comnet Communication network/ D-LinK |
| 14 | Supply and fixing in replacement DIN Rail Mounting 240 Watt @ 48 Volt DC Power Supply converter AC-DC auto Select 115/230 VAC Input Voltage as per Model No PS-DRA240-48A Complete mounting as per existing place all as specified and directed .Make - Comnet Communication network/ D-LinK |
| 15 | Supply and fixing in replacement of Single pole MCB 6-32 Amps ,10KA,230 volts complete all as specified and directed.Make -L&T/Legrand/ Havells /Indo Asian/Siemens |
| 16 | Material & Labour for PCC1:3:6 typeC-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for burried in the ground of supporting angle iron pole/picket of fencing complete and including any to be required form work etc all as specified and directed. |
| 17 | Supply and fixing in replacement of NVR ( Network video recorder) 64 channel with support IP camera upto 12 MP and storage 80 TB HDD capacity and 320 mbps encoding bit rate , support various VCA detection alarm and VCA search and support H.265 / H.264/ MPEG4complete all as specified and directed. Make - CP plus/ Panasonic /Bajaj |
| 18 | M & L for cutting/fabrication ,fixing & welding of MS angle iron of size as per site requirement for fixing CCTV camera, fencing wire supports fixing brackets etc including bracing ,supports ,clamps,and back plates fabricated from structural steel section including Nuts & Bolts ,washers,welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint inclusive of one coat of Red Oxide Zinc chrome paint and two coat of alumunium paint complete all specifed and as directed.Note:- The cost of PCC work for fixing of structure will be measured seperately. Please Enable Macros to View BoQ information |
| 19 | M & L for cutting/fabrication ,fixing & welding of MS angle iron of size as per site requirement for fixing CCTV camera, fencing wire supports fixing brackets etc including bracing ,supports ,clamps,and back plates fabricated from structural steel section including Nuts & Bolts ,washers,welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint inclusive of one coat of Red Oxide Zinc chrome paint and two coat of alumunium paint complete all specifed and as directed.Note:- The cost of PCC work for fixing of structure will be measured seperately. Please Enable Macros to View BoQ information |