| 1 | Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCB's, DB's any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&F small pieces of elctrical cable of size upto 10 Sqmm single core and length not exceeding 0.50m, complete all as specified and as directed.Note : (i) Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only.(ii) Cost of labour for replacement/ attending five complaints in same building number will be treated as one job |
| 2 | Note for item No 01:- (a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work. |
| 3 | (b) All bldg light complaints including service connection, sub main & internal electric for entire OTM and Md accn at CQAE shall be attended |
| 4 | (c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs. |
| 5 | (d) All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt. |
| 6 | (e) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. |
| 7 | (f) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor shall be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. |
| 8 | (g) The decision of the Accepting Officer in this regard shall be final and binding. |
| 9 | Supply only switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 10 | Supply only shuttered socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 11 | Supply only shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 12 | Supply only shuttered switch socket outlet 2 in 1, 5 pin, 5/6 and 15/16 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 13 | Supply only switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 14 | Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton |
| 15 | Supply only bell push, piono type 5/6 Amp, complete all as specified and directed.Make : Anchor/ Cona/ Havells/ Indoasian |
| 16 | Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed. Make : Havells / Anchor/ Crabtree. |
| 17 | Supply only of ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed. |
| 18 | Supply only plug top 3 pin 15 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/Anchor |
| 19 | Supply only PVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 Sqmm of single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza. |
| 20 | Supply only 4 mfd condensor for exhaust fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton |
| 21 | Supply only modular switch 1 way 6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 22 | Supply only modular switch 1 way 16 Amp,1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 23 | Supply only modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 24 | Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 25 | Supply only modular switch 2 way 6 Amp, 1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 26 | Supply only Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed. |
| 27 | Supply only Modular bell push, piono type 5/6 Amp, complete all as specified and directed.Make : Anchor/ Cona/ Havells/ Indoasian |
| 28 | Supply only plug top 3 pin 5 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Anchor |
| 29 | Supply only PVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm of single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza. |
| 30 | Supply only PVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 Sqmm of single core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza. |
| 31 | Supply only electronic LED driver 36/40 W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . |
| 32 | Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, complete all as specified and directed.Make : Legrand/ L&T/ Indo Asian |
| 33 | Supply only insulation tape 25 mm width 10m long (ISI Marked), complete all as specified and directed. |
| 34 | Supply only electronic LED driver 10/12 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . |
| 35 | Supply only metal clad switch socket single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Legrand/ L&T/ Indo Asian |
| 36 | Supply only TPN, MCB 20 to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian |
| 37 | Supply only SPN MCB 40 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 38 | M& L in repair PVC Casing & Capping medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed. |
| 39 | M& L in repair PVC Casing & Capping medium 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed. |
| 40 | M& L in repair PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed. |
| 41 | M& L in repair PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed. |
| 42 | M& L in repair PVC Flexible conduit of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor complete all as specified and as directed. |
| 43 | M& L in repair PVC Flexible conduit of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor complete all as specified and as directed. |
| 44 | M&L for Cutting chases, pinning in brick wall making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 45 | M&L for Cutting chases, pinning in. making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed. |
| 46 | Taking down of old U/S submain wiring of any type complete all as specified and directed. |
| 47 | S&F Sub main wiring with 2 runs of single core, 2.5 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 2.5 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire alongwith PVC conduit/casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza |
| 48 | S&F Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire alongwith PVC conduit/casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza |
| 49 | S&F factory made powder coated distribution board VTPN, 8 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 50 | S&F in replacement distribution board MCCB four pole, 160 Amp ultimate breaking capacity 25 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 51 | Taking down of old U/S MCB DB SPN with MCB any type complete all as specified and directed. |
| 52 | S&F factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 53 | S&F factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 54 | S & F MCB SPN 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 55 | Taking down of old U/S earth enclosure with MCB any type complete all as specified and directed. |
| 56 | Supply and Fix triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 10A- 63 Amps with accessories complete all as specified and as directed. Make Legrand /Schneider /ABB |
| 57 | S&F of Single pole and neutral enclosure with a two pin and earth plug and socket with single pole MCB 32 Amps complete all as pecified and directed. Make Legrand /Schneider /ABB |
| 58 | Taking down carefully copper/aluminium point wiring (light, fan, Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc and making good disturbed surface of wall, floors , roof etc all as specified and directed. |
| 59 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 60 | All as per item No. 59 here in before but for one light point controlled by one way switch. |
| 61 | All as per item No. 59 here in before but for one Exhaust fan/ceilling fan controlled by one by one way switch. |
| 62 | All as per item No. 59 here in before but for one bell point controlled by one bell push. |
| 63 | All as per item No.59 here in before but for one 3 pin socket outlet 5/6 Amp on the same board |
| 64 | All as per item No. 59 here in before but for one switch socket outlet 3 pin 5/6 Amps on independent board |
| 65 | All as per item No. 59 here -in - before but for One light point controlled by two, two way switches. |
| 66 | All as per Sl No 59 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor (FRLS) controlled by one 15/16A switch socket independently complete all as specified and directed. |
| 67 | Taking down of old switch /socket /regulator/ bell push complete all as specified and directed. |
| 68 | Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 69 | Supply and Fix switch piano flush type 15/16 Amps 240 volts complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 70 | Supply and Fix switch piano flush type 5/6 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 71 | Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 72 | Supply and Fix shuttered socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 73 | Supply and Fix shuttered switch socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 74 | Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5/6 and 15/16 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 75 | S&F electronic fan regulator stepped type for ceiling fan complete all as specified and directed. |
| 76 | Supply & fix electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T/ Indoasian |
| 77 | Supply & fix electric gong bell, AC 230 volt, single pole type complete all as specified and directed. Make : Anchor/Havells/L&T/ Indoasian |
| 78 | Taking down of old U/S light fitting of any type complete all as specified and direct. |
| 79 | Supply and Fixing of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells. |
| 80 | S&F 35/36 W( WW/WH) LED recess /surface type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. Make : Philips/ Bajaj /CG/Havells. |
| 81 | S&F LED bed side light /wall light/study light environmentel friendly energy effcient of capacity 3 W warm white etc,inbuilt driver complete with all accessories internally pre-wired swing type and including connecting up to with twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj / Philips / Wipro/CG |
| 82 | Supply & Fixing in repair electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . |
| 83 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 4\\"x 4\\" all as specified and directed. |
| 84 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6\\"x 4\\" all as specified and directed. |
| 85 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6\\"x 8\\" all as specified and directed. Please Enable Macros to View BoQ information |
| 86 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6\\"x 8\\" all as specified and directed. Please Enable Macros to View BoQ information |