| 1 | Schedule 'A' B/R |
| 2 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation etc., not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth and getting out in soft/loose soil, complete all as specified and directed by Engr-in-charge. |
| 3 | Material & Labour for Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded stone agg) as in foundation, filling and mass concrete, complete all as specified and directed by Engr-in-charge. |
| 4 | Material & Labour for (Porbandar stone of size 20cm x40 cm) Walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4), complete all as specified and directed by Engr-in-charge. |
| 5 | Material & Labour for Rendering 15mm thick in cement mortar 1:4 on concrete/stone masonary surfaces finished even and fair without using extra cement, complete all as specified and directed by Engr-in-charge. |
| 6 | Returning filling in, including spreading leveling, watering and well ramming in layer not exceeding 25 cm in soft/loose soil, complete all as specified and directed by Engr-in-charge. |
| 7 | Removal of excavated soil to a distance not exceeding 50 Metre and depositing where directed at level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engr-in-charge. |
| 8 | Material & Labour for RCC M-30, using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engr-in-charge. |
| 9 | Material & Labour for RCC M-30 (using 20mm graded stone agg) as in Beams and alike, complete all as specified and directed by Engr-in-charge. |
| 10 | Material & Labour for RCC M-30, using 20mm graded stone aggregate, as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engr-in-charge. |
| 11 | Material & Labour for RCC M-30, using 20mm graded stone aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engr-in-charge. |
| 12 | Use and waste of formwork to the sides of concrete footing, base of columns, plinth beams and similar work for vertical or to batter rough finished surfaces of concrete, complete all as specified and directed by Engr-in-charge. |
| 13 | Use and waste of formwork to sides and soffits of beams, bands and the like for rough finished surface of concrete. |
| 14 | Use and waste of formwork to the sides of rectangular columns for rough finished surfaces of concrete, complete all as specified and directed by Engr-in-charge. |
| 15 | Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)rough finished surfaces of concrete, complete all as specified and directed by Engr-in-charge. |
| 16 | Use and waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed by Engr-in-charge. |
| 17 | Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engr-in-charge. |
| 18 | All as per item here-in-before, but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed by Engr-in-charge. |
| 19 | Material & Labour for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and directed by Engr-in-charge. |
| 20 | Material & Labour for providing and fixing stainless steel (Grade 316) railing made of hollow tubes, channels, plates, chain, ornamental railing cap etc., including welding, grinding, buffing, polishing and making curvature (where-ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc,. of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed by Engr-in-charge. |
| 21 | Material & Labour for 20mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engr-in-charge. |
| 22 | Material & Labour for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15mm thick screed in Cement Mortar 1:6, complete all as specified and directed by Engr-in-charge. |
| 23 | Schedule 'A' E/M |
| 24 | Supply and Installation of Siren System Range 8000 RPM Electrical Siren VT 2KM, Type : Electrical Siren, Mounting Type : Double Ended, Phase : Single, Material : Aluminium Casting Body, complete all as specified and directed by Engineer-in-Charge.Make: Custom/Palex/SKP/Afex fire & safety |
| 25 | Supply and Installation of 6-Input Compact Stereo Mixer 6-channel standalone mixer (no USB) Featuring studio-grade discrete class-A D-PRE pre amps with inverted Darlington circuit - providing fat, natural sounding bass and smooth, soaring highs 3-band EQ and high-pass filters give you maximum control and eliminate unwanted noise, resulting in a cleaner mix1-Knob compressors allow easy control - resulting in livelier guitars, punchier bass lines, a tighter snare and a cleaner vocal sound, complete all as specified and directed by Engineer-in-Charge.Make: Bose. Model: T8S / Yamaha/sonodyne /studio masters |
| 26 | Supply and Installation of DSP Power Amplifier DSP power amplifier/ 4 channel, 70V/100V mono at 1200W Watts per channel, complete all as specified and directed by Engineer-in-Charge.Make: Bose/Crown/Ati pro. Model: Bose Power space P21000A/NCDI2X1200BL |
| 27 | Supply and Installation of Ultra-Compact Indoor/Outdoor Background/Fore ground Speaker Ultra-Compact Indoor/Outdoor Background/Fore ground Speaker Including JBL MTC-23WMG-1 Weather Max Grill and JBL MTC-PC2 Weather Resistance Panel Covers. Components:• 3” woofer with woven fiberglass cone• 1/2” PEI diaphragm tweeter with fluid cooling Contemporary, high-design appearance Weather resistant enclosure and transducers Wide 100° x 100° coverage 50 Watt power handling (100 Watt program) in direct 8Ω setting, plus built-in 15 Watt 70V/100V multi-tap transformer. High fidelity sound character with broad frequency response of 70 Hz – 20 kHz. The MTC-23WMG-1 is a high humidity replacement grill for JBL Control Series The MTC-23WMG-1 grills are made of a rust proof powder coated aluminum alloy to provide greater protection and extend the service life.. JBL MTC-PC2 Weather Resistance Panel Covers installs over the existing input cup, provides a water tight gland-fitting entrance to seal and protect this section of the loud speaker against incursion of water, complete all as specified and directed by Engineer-in-Charge.Make: JBL/Bose/Ahuja. Model: JBL Control 23-1, MTC-23WMG-1 and JBL MTC-PC2/ Bose Free Space FS2SE |
| 28 | Supply and Installation of Hand held Microphone Audio frequency band width:40 - 20000 Hz Sensitivity: 2.5 mV/Pa, Electrical impedance:600 Ohms, Recommended load impedance:2000 Ohms, Polar Pattern: Cardioid, complete all as specified and directed by Engineer-in-Charge.Make: AKG/ Shure. Model: AKG P3S/ Shure SM58 |
| 29 | Supply and Installation Speaker cable and Laying conductor, Material: Tinned Copper Size: 2x20 AWG, Insulation Material: PP, Color: Black, Electric Temperature rating: 75˚C, Insulation resistance: DC–500V 100MΩ/KM MIN. at 20℃, Conductor resistance: 20AWG–34.6Ω/KM MAX. at 20℃, Impedance: 40~100Ω, STANDARDS COMPLIANCEUL: CM RoHS: 2011/65/ EU, complete all as specified and directed by Engineer-in-Charge.Make: Krystal/Belden/remtek. |
| 30 | Supply & Mounting of weather rated speaker Mounting poles as per the site requirement, complete all as specified and directed by Engineer-in-Charge.Make-JBL/ avtron /ahuja radios |
| 31 | Supply and laying 50 /38mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, complete all as specified and directed by Engineer-in-Charge.Make: Rex/Poly/Gemini |
| 32 | Supply and fixing BEE five star eated energy efficient high-speed ceiling fan having 1200mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |