| 1 | Supply of MEDICAL, SURGICAL ITEM |
| 2 | ADULT WEIGHT MACHINE 1. Sturdy dial type mechanical platform weighing machine with magnifying mirror for adult andchildren. 2. Zero adjustment facility should be there. 3. Should have accuracy and resolution of 500gram4. Range of weighing: 0 to150kg 5. The manufacturer shall have the valid license and should have model approval by the legal metrological department and the weighing scale must be stamped by the by legal metrological department. 6,Manufacturer should have ISO 9001.7. Guarantee: Three years on full product (including battery) from the date of installation. |
| 3 | CTG MACHINE (FETAL MONITOR)1. Fetal monitor for recording and analyzing the Fetal Heart Rate (FHR) on beat-to-beat basis.2. Toco and Maternally sensed fetal movements. both manually and automatically detected3. Should have facility of twin monitoring.4. Should have built-in printer with multiple printing speed and automatic paper feeding facility.5. Fetal monitor should have inbuilt rechargeable battery of atleast 60 min. backup.6. Display of FHR upto Twins FHR1 & FHR2 & TOCO on 10\\" or more display.7. Heart rate offset mode to visually distinguish between the heart rates of twins with ability to offsetthe secondary FHR by atleast 20 BPM.8. Uterine contractions alarm. Alarm delay facility, so that alarm is available only if the alarmingcondition is persistent for preset time. User friendly alarms and patient data.9. Actual FHR in BPM.10. Blinking corresponding to each Beat.11. Patient Name / ID, date and time, Memory Backup/Graphical or Tabular trend for minimum 24hours with fast printing facility.12. In-built / Separate Acoustic Stimulator with a separate marker on the graph for acoustic stimulators.13. Ultrasound transducer should be multi crystal wide beam pulsed Doppler with frequency of 1MHz. 14. Fetal Heart Rate - measurements Range: 50-220 BPM.15. External toco transducer which should be a sealed waterproof unit. Guard ring designed to reducematernal respiration artifact. Measurement Range: 0-99 Units.16. Event Market - Hand held, patient operated as well as front panel operated. Voltage 230V A.C.±10%, 50 Hz.17. Product should be European CE / USFDA certified.18. Guarantee: Three Years on equipment from the date of installation.20. Installation will be done by supplier free of cost.21. List of spare parts and accessories to be supplied.22. Company should have Service Network in Rajasthan.23. The company should mention the make & model name/number of the quoted equipment and submit .the technical brochure of the quoted model in the technical bid along with compliance sheet as per technical specifications.24. Should be supplied with following accessories:- a) FHR Probe - 2 Nos. b) TOCO Probe - 1 No.c) Event Marker - 1 No. d) Fetal Simulator - 1 No. e) Probe Belt - 3 Nos. f) Ultrasound gel - 10 Nos. g) Compatible Paper roll - 10 Nos. h) Power Cable - 1 No. i) Movable Trolley with cover - 1 No.26. Final technical approval after demonstration on patient. |
| 4 | Instrument tray INSTRUMENTS TRAY 12\\" X 8\\", STAINLESS STEEL , ISO CERTIFIED ,WITH LID COVER |
| 5 | DIGITAL BP APPARATUS Mercury free,Should measure blood pressure and pulse rate in adult as well as pediatric patients.Based on oscillometric measurement technology using dynamic linear deflation method.Backlight LCD/LED display.Pressure range: 0–299 mmHg with accuracy ±5 mmHg.Pulse rate range: 40–180 bpm with accuracy within 5%. Memory storage for 60 patients or more.Single button operation with auto-inflation cuff (latex-free). Irregular heartbeat (IHB) indicator with cuff fit and movement error indicator.Auto deflation pressure release valve. Operating temperature: 0°C to 45°C (suitable for Rajasthan weather).Battery life approx. 300 measurements.Supplied with adaptor and replaceable AA batteries.Operates on AC adapter and user replaceable AA batteries.Manufacturer ISO 13485 certified. Model should be BIS/US-FDA/European CE approved.Box contents: Latex-free arm cuffs (large & medium), tubing, AA batteries, AC adapter/charger, user manual.Final approval after technical committee inspection.Local service center in Rajasthan required. 1-year warranty including battery and charger. |
| 6 | DIGITAL INFANT WEIGHTING SCALEIt is a table top electronic scale with built in rechargeable system and has: Easy to clean acrylic (non metallic) baby tray Resolution of 5 gram Freeze reading display Zero weight adjustment facility e Quick, clear, digital readouts |
| 7 | DRESSING DRUMStainless steel Dressing drum Seamless Size 11 x 9, ISO CERTIFIED |
| 8 | AUTOCLAVETechnical Specifications (30 Ltr Vertical):Capacity: 30 Ltr.Dimensions: Chamber of diameter 350mm and overall height 300-325mm.Construction: Vertical steam autoclave with a stainless steel chamber and dome-shaped lid, often featuring a silicone door gasket.Heating: Electrically heated, usually with a 2KW immersion-type heater (220/230V, 50 Hz AC).Pressure: Operates at 1.1 to 1.2 kg/cm² (15-18 PSI).Safety Features: Equipped with a pressure gauge, safety valve, and steam release valve.Certification: Should conform to IS 8462:1977.Warranty/Service: Recent tenders have specified a 3-year warranty for these items. |
| 9 | PATIENT EXAMINATION TABLEEXAMINATION TABLE (2 SECTION) Overall approx size: 1800 X 500 X 800 mm, Framework of CRS tubes, adjustable backrest of ratchet, Pre–treated and epoxy powder coated.Examination Table Mattress size: 1800 X 500 mm |
| 10 | GLUCOMETER codefree with 100 Strips Codefree,It should be a hand held meter.Measurement Range: Must measure blood sugar between 20 mg/dL and 500 mg/dL (some documents specify up to 600 mg/dL).Sample Size: Requires a small blood sample of 1–2 µL.Testing Speed: Should deliver accurate results within 5–8 seconds.Calibration: Must feature a \\"No Coding\\" system for automatic calibration.Memory: Capable of storing at least 200 tests with date and time.Display: Large LCD screen with symbols for easy reading.Detection: Built-in under-dosing detection system to alert if the blood sample on the strip is insufficient |
| 11 | NEBULIZER MACHINEType: Piston Compression or Atomiser-type electric aspirator.Operating Voltage: 230V AC (50 Hz).Maximum Pressure: Approximately 35 psi.Air Flow Rate: Minimum 14 litres per minute (LPM).Aerosol Output: 106 per minute with a residual volume of approx. 1.24 ml.Particle Size (MMAD): Approximately 3.3 microns (ideal therapeutic range is 1-5 microns).Medicine Cup Capacity: Minimum 5 ml.Usage Compatibility: Designed for continuous use and must be motion-tolerant for transportation.Noise Level: Maximum 60 dBA (verified via NABL accredited laboratory reports), CE Certified |
| 12 | FINGURE PULSE OXIMETERISO CERTIFIED This fingertip oxymeter is intended for measuring the pulse rate and functional oxygen saturation (SpOr) through a patient's finger from adult to pediatric patient. 2. lt should display SpO2-, PR, Plethysmogram and Perfusion Index. 3. Best Features: Auto Power Off, Water Resistant, Buzzer- Visual Alarm, Dual segment LED. Low battery indication.4. Quick, Accurate and Easy To Use - lt's newly designed monitor gives instantsaturation (SpOr), pulse rate (PR), Plethysmogram and displays them on a display clearly shows inconsistencies. lts display can rotate in four directions. 5. The quoted model should be European CE (Notified Body)/USFDA/BlS Certified. |
| 13 | Patient Foot StepDouble made of 16 gauge pipe and 20 gauge sheet |
| 14 | Xray View BoxNo. of Films1Thickness 25 mm Dimensions (L x H) 825 x 530 mm LED Intensity 15000 LUX |
| 15 | hb meter with 100 strips and 100 lenslet LCD DISPLAY, HIGH SENSITIVITY , Maximum volume of sample required Not more than 50ul (One full blood drop) Sample material Measuring time Auto-calibration Capillary, venous or arterial whole bloodLess than one minute Auto/self calibration |
| 16 | LABOUR TABLE WITH MATTRESSTop Of Double Bent M.S. sheet Provide with Gynae Cut For Procedure at legend side and Top Of Double Bent M.S. sheet Provide with Gynae Cut For Procedure at leg end side and Top Frame is made of tubular frame work or angle frame work or angle frame work with M. S. sheet top WITH Rexine Cover Mattress. SIZE 72’ l x 30 w X 30 h |
| 17 | PLASTIC BMW BUCKETS 4 set with PedaLRed, Yellow and black, BLUE, 20 LTR Premium Plastic |
| 18 | PATIENT STOOL Tubular Tripod base with S S Revolving Top Height Adjustable From Approx 480 mm to 670 mm by accurately machines screw mechanism leg fitted with rubber shoe pre treated and powder coated. |
| 19 | Patient Slide SCREEN WITH CURTAINS (3folder)M S Tubular Pipe Construction in Three Fold with Hook Mounted on Swivelling Castors 50 mm dia finish in epoxy powder coated with curtain set. Size 66 H x 96 L Finish Pre treated and epoxy powder coated |
| 20 | BED SIDE LOCKER Overall approx size: 350 mm × 350 mm × 800 mm. Tubular pipe construction with PVC stumps Stainless steel topPre-treated and epoxy powder coated |
| 21 | IV STAND M.S. tubular pipe frame. Five-leg base with 50 mm castors S.S. adjustable rod: 137 to 240 cm Double hookPre-treated and epoxy powder coated |
| 22 | STADIOMETER (Height Measurement Scale)Stadiometer use in medical device use to accuracy measure human height. wall mounted fixed |
| 23 | STANDING BP INSTRUMENT MERCURY FREE Portable type stand model ISI mark measuring Range From 0 to 300 MM of HG Control Valve should have a thumb control device. B P Instrument With Stand with strong Leg fitted with castors. |
| 24 | SUCTION MACHINE Pump Type: Must feature a low-vacuum, low-flow, oil-free vacuum pump.Vacuum Range: Regulatable from 0 to 700 mmHg ± 10%.Flow Rate: Must provide a flow rate of at least 40 Liters/min, which should be adjustable.Motor: Equipped with a 1/ 2 HP single-phase, 1440 rpm motor with ISI/ISO/BIS/IS: 996 marking. |
| 25 | WHEEL CHAIRISO CERTIFIED |
| 26 | PATIEN BED WITH MATRESSES Hospital Bed Tubular head and foot bows of unequal height with vertical tube support, framework made up of M.S. tubes, Top made up of perforated CRCA M.S. sheet, legs fitted with PVC stumps, Overall approx size 1900 X 910 X 600 mm.matresses should be provided with this |
| 27 | ECG Machine 12 CHANNEL It should have In-built Thermal Printer 2. Automatic Manual Recording Modes with long lead rhythm strip. 3. 3/6/12 Channel Print Format on A-4 Size Thermal Paper 4. 12 Lead Monitoring Simultaneously on TFT/LCD/LED display, size 7\\" or more 5. Should have 12 lead ECG preview display before taking printouts 6. It should have water proof Keyboard or Touch Screen Keyboard (touch pad) 7. Mains & Battery Operated 8. In-built Rechargeable Battery for minimum 4hour battery backup on full charged. 9. It should have pacemaker detection 10. It should have facility of visual alarm for open icad. 11. CMRR should be 90 or more 12. Frequency Response 0.0511z to 150Hz 13. Memory for 200 ECG or more 14. Patient Leakage Current:Web Cam Integrated HD Web Camera (Front facing) Battery Minimum 40Whr Power Adapter Standard power adapter Antivirus Minimum 3 years subscription Antivirus with protection for Ransomware, Browsing, Phishing along with OEM undertaking to be provided. Model specific Certification BIS Compliance RoHS, ISO 9001 Accessories Carry Bag Warranty 3 Years comprehensive on site OEM warranty |
| 28 | FETAL DOPPLERTransducer/Probe: Multi-crystal wide beam pulsed Doppler probe with a frequency typically of 1 MHz to 2.5 MHz.Heart Rate Range: Measurement range of 50–220 BPM or up to 240 BPM in some models.Signal Processing: Utilises Auto Correlation technology for accurate and reliable fetal heart rate (FHR) detection.Audio Output: High-fidelity built-in speaker with adjustable volume and a headphone jack for private listening.Display: Backlit LCD or TFT display showing real-time FHR, average FHR, and battery status.Power: Powered by rechargeable Ni-Mh or Li-ion batteries; usually compatible with 230V AC ± 10%, 50 Hz power supply.afety Standards: Equipment must be USFDA or European CE certified and comply with IEC 60601-1 electrical safety standards. |
| 29 | Suturing set (1 SET MUST INCLUDE THESE ITEMS)TOOTH FORCEP,STRAIGHT ARTERY FORCEPS,NEEDLE HOLDER,SUTURE CUTTING SCCIOR , CURVED ARTERY FORCPES Please Enable Macros to View BoQ information |