| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: PROVISION OF DEFICIENT MD ACCN WITH ASSOCIATED INFRASTRUCTURE AT AF STATION MOHANBARI Contract No: CE(AF)SZ/MHB/ OF 2025-2026 File No: 88676/MHB/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE \\"A\\" PART- I(BUILDINGS/STRUCTURES WORK) Details of prepriced Schedule is given in tender documents |
| 3 | SCHEDULE \\"A\\" PART- IA(PILE FOUNDATION) Details of prepriced Schedule is given in tender documents |
| 4 | SCHEDULE \\"A\\" PART- II (SITE CLEARANCE AND AREA DEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 5 | SCHEDULE \\"A\\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \\"A\\" PART-IV (INTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 7 | SCHEDULE \\"A\\" PART- V (ROAD/PATH/CULVERT)Details of prepriced Schedule is given in tender documents. |
| 8 | SCHEDULE \\"A\\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \\"A\\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \\"A\\" PART- VIII (FIRE POINT)Details of prepriced Schedule is given in tender documents |
| 11 | SCHEDULE \\"A\\" PART- IX(UG SUMP)Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \\"A\\" PART- X(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 13 | SCHEDULE \\"A\\" PART- XI(EXTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents |
| 14 | SCHEDULE \\"A\\" PART- XII(LIGHTNING ARRESTER)Details of prepriced Schedule is given in tender documents |
| 15 | SCHEDULE \\"A\\" PART- XIII(FIRE FIGHTING AND FIRE ALARM SYSTEM)Details of prepriced Schedule is given in tender documents |
| 16 | SCHEDULE \\"A\\" PART- XIV(LIFT)Details of prepriced Schedule is given in tender documents |
| 17 | SCHEDULE \\"A\\" PART- XV(DEMOLITION /DISMANTLING)Details of prepriced Schedule is given in tender documents |
| 18 | SCHEDULE \\"A\\" PART -XVI(MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 19 | INTERNAL ELECTRIFICATIONS&F TV socket single module, polycarbonate type complete with box, complete all as specified & directed. |
| 20 | S&F LED lamp 10 Watt, complete all as specified and directed. |
| 21 | S&F LED security light fitting not less than1x35 watt of minimum lumen efficiency of 110 lm/W with integral reflector made of aluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5M long bend to shape of dia. 25/40 mm GI medium grade pipe with MS clamp including two coats of aluminium paint over a coat of red oxide primer and necessary fixing fasteners, complete all as specified and directed. |
| 22 | Supply and fix MCCB 415 Volts, 4 Pole, 63 Amps, 50 Hz, 16 KA with thermal magnetic release type, complete all as specified and directed. |
| 23 | Supply and fix MCB 230 Volts, 50 Hz, Single Pole, 40 Amps, 10 KA with \\"C\\" curve complete all as specified and directed. |
| 24 | M&L for Single Phase sub main wiring with 3 run of FRLSH type PVC insulated & unsheathed multistranded copper conductor cable of nominal cross sectional area 10 sqmm alongwith one run of FRLSH type PVC insulated & unsheathed multistranded copper conductor cable of nominal cross sectional area 10 sqmm as earth continuity conductor drawn through and including concealed PVC conduit non metalic type rigid medium grade complete all as specified and as directed. NOTE : Three run of submain wiring cable alongwith one run of earth wire including one run of PVC conduit shall be measured as one unit. |
| 25 | M&L Earthing complete with galvanized steel earth plate electrode 600mm x600mm x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected with galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 15mm bore light grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanised iron wire mesh charcoal or cock and common salt in alternate layer of 15cm (compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1, 50mm thick precast RCC (1:2:4) B1 nominal mix cover slab of size 450mmx450mm reinforced with 8mm dia TMT bar 100mm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in any type of soil and deposite surplus soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No 3 of MES Shedule Part -l complete all as specified and directed.Note:- The quoted rate of above item includes supply and fixing of earth identification plate as directed and necessary weather coat paint on exposed part of earth pit complete all as directed. |
| 26 | INTERNAL WATER SUPPLYS&F for 15 mm bore, two way type, bib tap(suitable for fixing a health faust), fancy type, CP, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. |
| 27 | Supply and fixing 15mm bore mixer for WHB (Hot & cold) cast copper alloy chromium plated with long shank and cup fancy type, screw down, high pressure with crutch or butterfly handle, including three joints to steel/CPVC pipe or union and plugging and screw to wall, complete all as specified and as directed. |
| 28 | SEWAGE DISPOSALM&L for construction of RCC Septic tank conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 typ D-2 foundation bed, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc. with Vent shaft , manhole openings with cover connection etc. with effective depth of 1.5 mtr and overall depth of 3.0 mtr complete for 100 users including RFR, removal, complete all as directed and shown in drawings. |
| 29 | M&L for construction of soakage wells ,excavation in any type of soil, foundation in PCC 1:3:6 type C-2, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 mtr dia x 3.0 mtr effective depth complete all as directed and shown in drawings. |
| 30 | EXTERNAL WATER SUPPLYSupply and install 7.5 HP, 3 Phase, 415 Volts, 50 Hz, minimum 39 mtr head, 500 LPM self priming openwell submersible pump set minimum 3 star includind suction and delivery pipe and mounting arrangement with suitable size of nut bolts and washer complete suitable for 80 mm GI pipe in suction and delivery line with all accessories, complete all as specified and directed. |
| 31 | Supply and fixing of PVC insulated copper conductor submersssible cable FR Type, water proofing, of size 10 sqmm 3 core,1100 Volts grade,multistranded with all accessories, complete all as specified and directed. |
| 32 | Construction of brick masonry valve pit of size 900mm x 900mm x 900mm (outer dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level providing valve pit 40 x 40 x 6mm angle iron frame all-round the fixed point by means of 4Nos holdfast made out of flat iron 40 x 6mm x 150 mm long bent to shape embedded using 150 mm long bolt with anchor plate in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 3mm thick welded to angle 40 x 40 x 6 mm, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm dia pad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed. |
| 33 | EXTERNAL ELECTRIFICATIONSupply, installation, testing and commissioning of step down outdoor type copper wound, Oil cooled transformer of capacity 160 KVA complete with standard, filling HT 11KV, 3 Phase, LT 433 volts, 3 phase 4 wire (Dyn 11) with off load temp changer with range +7.5 to -7.5% in steps of 2.5% on HT side to vary secondary voltage all as per IS 1180 Level-II complete all as specified and as directed.(as per IS 1180:2021 or Latest Revision) (1) Technical Details(a) No load Voltage Ratio (Normal Tap)- 11000/433V(b) Number of Phase: Three(c) Frequency: 50 Hz(d) Type of Cooling: ONAN(e) Winding connection: The primary winding (HV) shall be connected in delta and secondary winding (LV) shall be connected in star.(f) Vector Group: Windings shall be connected as per Vector symbol: Dyn 11(g) Neutral Earthing: The neutral point of Secondary (LV) winding shall be brought out to a separate insulated terminal and shall be solidly earthed.(h) Off Load Tap Changer of the transformer: Voltage tapping range on H.V. side will be (+7.5%) to (-7.5%) insteps of 2.5%. The tap changing switch shall be located in a convenient position so that it can be operate from ground level. The switch handle shall be provided with a locking arrangement along with tap position 1(+7.5%) & 7 (-7.5%) .(j) The percentage impedance at 75 deg C & 50 Hz refer to the (normal) principal Tapping shall be as per BIS BEE rating.(k) Losses: Minimum losses as per BIS BEE rating. |
| 34 | (Srl Item No. 32.00 Contd...)(2) Structural Details: The transformer shall be comprising of the following items:-(a) Externally hand operate off-circuit Tap Changer witch with position indicator and locking device.(b) Conservator with Oil gauge, filling Hole with plug and drain hole with plug. (c ) Undercarriage with foul plain rollers.(d) Oil filling hole cum air release plug.(e) Drain Valve cum sampling valve.(f) Filter valve with Plug.(g) Lifiting Lugs for Transformers.(h) Lifting Lugs for Lid.(j) Earthing Terminals. (k) Thermometer Pocket.(l) Silicagel Breather.(m) Inspection Cover.(n) Explosion Vent.(o) 6 inches Dial type temperature indicator with Metal Guard.(p) Rating Plate and Diagram Plate.(Note: First time Transformer Oil filling is deemed to be included in quoted rate) |
| 35 | Supply and fixing of HOT moulded (FRP) SMC jucntion box for street light pole with locking arrangementt hinged door with IP -65 protection of size 200 x 250 X 105 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and directed. |
| 36 | Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 0.80mx0.6mx0.4m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement ,louvers at sides & duly powder coated including in-panel CO2/Clean agent fire suppressing system complete for accomodating & including following accessories:-(Main Panel)DETAILS:-INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity 36 kA of 320 Amps with fixed thermal and fixed magnetic setting- 01Nos OUTGOING: (i) MCCB 4 Pole ,415 Volts with breaking capacity 36 kA of capacity 200 Amps with thermal magnetic release -02 Nos (1 for Bldg Panel + 1 spare)(ii) MCCB 4 Pole ,415 Volts with breaking capacity 25 kA of capacity 100 Amps with thermal magnetic release -01 Nos (1 for change over Panel for DG Panel )BUSBAR: (i) Al bus bar 500 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii) Digital ampere meter of 0-300 A, 3 phase, class 1 , including CT having CTR 500/5 - 01 No(iii) Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No |
| 37 | Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.20mx0.9mx0.5m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement ,louvers at sides & duly powder coated including in-panel CO2/Clean agent fire suppressing system complete for accomodating & including following accessories:-DETAILS:-INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity 25 kA with capacity of 125 Amps - 01Nos.OUTGOING: (i) MCCB 4 Pole ,415 Volts with breaking capacity 25 kA of capacity 40 Amps with thermal magnetic release -03 Nos (ii) MCCB 4 Pole ,415 Volts with breaking capacity 25 kA of capacity 20 Amps with thermal magnetic release -02 Nos(iii) MCB SPN 32 Amps ,240 Volts with breaking capacity 10 kA -02 Nos (iv) Street Light Timer switch 230 V single phase of 20 Amps with contactor - 01 Nos (v) Automatic DOL Starter 415 Volts.50 Hz,3 Phase,7.5 HP including single phase preventer,overload relay protection,contacto - 02 NosBUSBAR: (i) Al bus bar 300 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii) Digital ampere meter of 0-300 A, 3 phase, class 1 , including CT having CTR 100/5 - 01 No(iii) Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No |
| 38 | Supply, install, testing and commissioning of LT Indoor Feeder Pillar Box wall mounted AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.0mx1.0mx0.35m, single door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement , louvers at sides duly powder coated including in-panel CO2/Clean agent fire suppressing system complete for accomodating & including following accessories:-DETAILS:-INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity 36 kA of 160 Amps with fixed thermal and fixed magnetic setting- 01 NosOUTGOING: (i) MCCB 4 Pole,415 Volts 32 Amps breaking capacity 16 kA with fixed thermal and fixed magnetic setting- 08 NosBUSBAR: (i) Copper bus bar 300 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii) Digital ampere meter of 0-300 A, 3 phase, class 1 , including CT having CTR 200/5 - 01 No(iii) Digital voltmeter 0-500 Volts, 3 phase, class 1 - 01 No |
| 39 | M&L for earthing complete with copper plate 600mm x 600mm x 3.15mm thick electrode and 20mm x 3mm copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to copper strip 20 x 3mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on pit cover as per colour code followed in AF Station.(ii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. |
| 40 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. complete with GI bracket 1.2M long bend to shape of dia. 32 mm GI medium grade pipe with MS clamp including two coats of aluminium paint over a coat of red oxide primer and necessary fixing fasteners, complete all as specified and directed. |
| 41 | Supplying and fixing in repair single run 3 core, 2.50 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting, complete all as specified and directed. |
| 42 | Supplying and fixing in repair single run 3 core, 1.50 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting, complete all as specified and directed. |
| 43 | Supply and fixing 20 mm nominal bore dia, UPVC pipes of pressure rating 10 kgf/cm2 fixed to pole, any type including provision MS clamp of size 20mm x 3mm flat at interval of 1.5 m length, complete all as specified and as directed |
| 44 | S&F of LED Aviation light luminaire having die-cast aluminium housing with polycarbonate enclosure ,drive and LEDs connected in series and parallel combination with better heat dissipation,09 Watt, 240 Volts,IP-65 With all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable and necessary mounting arrangements, complete all as specified and as directed |
| 45 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on pit cover as per colour code followed in AF Station.(ii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. |
| 46 | Supply and installation of 11KV Compact sub station with non extensible 3 way RMU consisting of 2 No. manually operated & one 11 KV/630 Amps VCB in SF6 insulated stainless enclosure, HT Cable/Bus Bar, 1 No. transformer 160 KVA, 11KV/0,433 V ONAN Cooled oil immersed copper wound step down transformer as per IS 1180(Part-I):2024 & associatedequipments including OTI, WTI & Marshalling Box complete all as specified and directed. |
| 47 | (Srl Item No. 44.00 Contd...)MAIN PANEL:-INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity 36 kA of 320 Amps with fixed thermal and fixed magnetic setting- 01 NosOUTGOING: (i) MCCB 4 Pole,415 Volts 160 Amps breaking capacity 36 kA with thermal magnetic release- 02 Nos (i) MCCB 4 Pole,415 Volts 125 Amps breaking capacity 25 kA with thermal magnetic release- 01 Nos BUSBAR: (i) Aluminium bus bar 500 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii) Digital ampere meter of 0-400 A, 3 phase, class 1 , including CT having CTR 400/5 - 01 No(iii) Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No |
| 48 | Supply and installation (above ground) including testing HT joint box 3 way outdoor type of size 1700x1500x1200 mm (overall) made out of 3.15 mm thick CRCA sheet with support of angle iron frame of size 40x40x6 mm with KIOSK BOX and comprising of 06 Nos. HT porcelain bushing and copper round bus bar 12 mm dia rigidly mounted on baelite sheet 12 mm thick to support insulators of suitable size and shape including providing electric connection and applying two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces (internally and externally) including PCC foundation base of size 1700mmx400mmx1200 mm height ( 700 mm above GL and 500 mm below GL) with PCC 1:3:6 TYPE C1 using 20mm graded aggregates complete including necessary excavation and earthwork for foundation and necessary electric connection complete including dismantling of unserviceable junction box complete all as specified and directed. |
| 49 | LIGHTENING ARRESTERS&F Lightning Arrester ASEEL THOR HELIOS equipped with stainless steel , full electrical continuity between the tip and the earth point, Radius coverage 90 Mtrs ASEEL THOR HELIOS type lighting protection complete with the Lighting Air terminal with stand a Minimum switching impluse voltage of 200 kA complies,including one unit of ASM/HB/F/C/50 for the fixing of Thor and lighting impluse counter digital type ,necesssary accessories to be installed roof of and the centre of the building , collect energy through including accessories of lighting arrester 5 mtr Mast with its installation accessories etc complete all as specified and directed. |
| 50 | S & F U clamp for holding the copper wounded rod complete all as specified and directed. |
| 51 | S&F suitable sized heavy duty bridge/post porcelain/mini busbar insulator on wall / roof with suitable size of PVC plugs / gutties,screws for fixing aluminium / GI strip incl. making good the disturbed surfaces complete all as specified and directed. |
| 52 | FIRE FIGHTING SYSTEMSupply and fix Cast Iron Air Valves with double air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia complete all as specified and directed. |
| 53 | Supply and fix of wireless modem suitable for GSM based communication system to be mounted in RTU enclosure to be installed in the buildings complete all as spcified and directed. |
| 54 | Supply, Installation, Testing and Commissioning of Glass Reinforced Poly plastic Sheet Moulded Compound panel terrace tank confirming to IS:14399 of 1966 and IS:4249 of 1967 of capacity 25000 Ltr for fire fighting system complete all as specified and directed. |
| 55 | Supply, installation, testing and commissioning of first aid fire hose reel wall mounting swinging type complete with drum, bracket, 20mm dia.and 30m length, high pressure hose reel tubing with gun metal shutoff nozzle conforming to IS:8090-1976. The hose reel shall be as per IS:884-1985, complete all as specified and directed. |
| 56 | Supply and installation of fire extinguisher (ABC) type of 6.0 Kg capacity confirming to IS: 15683, complete all as specified and directed. |
| 57 | Supply and installation of fire extinguisher light weight squeeze grip type CO2 of 4.5 Kg capacity confirming to IS: 15683, complete all as specified and directed. |
| 58 | Supply and installation of fire extinguisher mechanical foam extinguisher as per (IS 15638) 9 Ltr capacity confirming to IS: 15683, complete all as specified and directed. |
| 59 | S&F of Fire exit glow sign board green colour arrow showing dowm/right/left/up stair complete with LED luminairies of 5 watt and with lithium ion rechargeable battery for minimum 03 hr backup during no electric supply condition complete all as specified and directed. |
| 60 | Supply, Installation, Testing and Commissioning of RTU Logic dovelopment for center monitoring through wireless communication at master control station which include the dovelopment logic for fire alarm control panel including wireless modem suitable for GSM based communication system to be mounted in RTU encloser and shall be installed at building (it should also to be used as GSM based autodialer, to be installed with the main control panel having minimum 10 Nos mobile connection facility and atleast memory for voice recording of minimum five mounted data) including providing one GSM SIM card(including rental and SMS charges for period of one year) inport including TCP/IP card RS232 card is an optical card for RTU /control panel s, providing two photoelectric isolation RS232 interfaces for connecting with graphic moniter center and defining toll. Modify address of communication card including necessary programming as per site requirment, complete all as specified and directed. |
| 61 | LiftSupply and fix fire proof Lift suitable to carry 8 passengers (544 Kg) at Rated speed of 1.25 M/sec to serve upto 6th floors (G+6 floors), electrically operated Microprocessor based VVVF Drive system and Microprocessor based simplex selective collective control with/without attendent complete with power driven automatic, 3 phase AC 415 volts,50 Hz power supply , and having SS lift cabin with Moonrock finish of dimension 1300 x 1100 x 2200 mm , power operated center opening stainless steel (SS) sliding doors with Moonrock finish (two panel enclosure), ceiling LED light ,PVC floor,SS round handrail in rear side,Cross Flow Fan, 7/7 stops/opening with floor display characted (at each entrance position). Car operating Panel which includes stainless Steel car operating faceplate with Hairline Finish,Oval type Button,Orange Square Dot Matrix Scrolling display. Landing indicator includes JLLP01 type Landing operating panel,OSDM-V type Landing Display on wall,SS faceplate material with Hairline Finish,Call register signal and SS Braille Button .Having safety features like over speed governor,door protection,counter weight screen,over load indicator,fireman switch,automatic rescue device,battery operated emg alarm light & two way intercom with press & speak in car operating panel, complete all as specified and directed. |
| 62 | SIGNAGE BOARDS&F signages board of size exc 0.04 sqm but n.exc 0.06 sqm using photo-luminescent sheet, pasted on thisck aluminium sheet of 2mm thick & inscription (i.e Emergency exit, Fire alarm, Fire point, lift etc) made by the way of computerized Vinyl cutting & lamination, including necessary fittings for fixing the board complete all as specified and directed. |
| 63 | S&F signages board of size exc 0.50 sqm but n.exc 0.60 sqm using photo-luminescent sheet, pasted on thisck aluminium sheet of 2mm thick & inscription (\\"IF FIRE OCCURS\\" necessary data will be given at execution time by Engr-In-Charge) made by the way of computerized Vinyl cutting & lamination, including necessary fittings for fixing the board complete all as specified and directed. |
| 64 | DG SETSupply, installation, testing and commissioning of 60.0 KVA/48.0 KW, 84 Amps at 0.8 lag PF, canopied Genset, radiotor cooled, turbo charged, water cooled, diesel engine developing 64.0 BHP at 1500 RPM with fuel tank,12 Volt/180 AH battery, exhust silencer complete with AMF control panel and accessories like base frame, AVM pads, AVR with free standing floor mounted , cubicle compartmentalised, dust and vermin proof etc with following specification and all as per direction of the Engineer-in-Charge.Engine:- Diesel engine, direct injection, 4 strokes, four cylinders water cooled diesel engine developing of 64.0 BHP @ 1500RPM complete with engine safties and all stanard accessories as per the standard of BS-5514, ISO-3046 of make: Kirloskar or equivalent model of Cummins, Mahendra and Mahendra etc.Alternator:- Direct coupled with diesel engine having KVA rating 60 KVA and KW rating 48.0 KW at 0.8 PF, 415 volts, 50 Hz at 1500 RPM 3 Phase 4 wire system, class \\"h\\" insulation, IP-23 protection enclosure as per the standard of IS 4722, BS 5000 of make kirloskar or equivalent model of cummins, standford etc.Acoustic Enclosure:- Acoustic enclosure shall be powder coated and fabricated as per CPCB(IV+) norms, sound level shall be less than/=t5 dB (A) at one meter from enclosure in free filed conditiond as per ISO 8528.AMF Panel:- The microprocessor based AMF panel shall be with AMF controller suitable to start the engine on main failure after 10 to 15 Sec time delay and to switch off engine only after 60 to 90 Sec after the amin supply restored. The AMF contoller shall have under/over volatege/over load protection, cooolent temp cut off, fuel control upto 10% of tank capacity. The panel shall also have one change over switch and gears of suitable capacity to by pass main supply when the AMF control become defective. |
| 65 | (Srl Item No. 62.00 Contd...)Notes:-(i) The panel will be completed with internal wiring with suaitable size of multistrandard copper cable. The suitable control of AMF panels with all meters, control wires are included in the scope of work.(ii) Tools if any shall be supplied as per manufactures instructions and cost shall be included in the cost of DG set.(iii) Fuel tank shall be provided inside the canopy.(iv) Thermostat switch inside the accoustic enclosure shall be providedto shutt off the DG set in case of temprature increses beyond 97 degree celcious inside the accoustics enclosure. (v) There shall be proper air circulation and windows with glass in the accoustics enclosure suitably located to read the meters of various controls from outside.(vi) Necessory grouting including mild steel work and antivibration pad shall be provided bt the contractor.(vii) First filling of lubricants/engine oil and diesel for complete testing 10 % over loading for one hour in twelve hour duration by load test deemed to included in the items rate quoted.(viii) Necessary foundation for installation and plinth protection of the DG set shall be provided as per manufracture recommendation and cost deemed to be included on the items rate quoted.(ix) Necessory 10% over load test shall be carried out in the present of the Engineer-in-Charge and testing officer.(x) Shifting of DG set from showroom to the site by means of truck/creane is the responsiblity of the contractor. The cost incurred will be brone by the contractor. |
| 66 | SMART METERSupply, Set up and Tuning of Smart RF/Cellular/Hybrid (RF+Cellular) Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards including inbuilt Radio Frequency communication facility with self healing mesh network/ GPRS(Cellular) Network facility/ Hybrid Network facility as per design with default and on demand display,anti-tamper features, Microprocessor and LED/LCD based circuitry including SMC Meter Box of suitable size for Single Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency. Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Note: This will also include Cost of Planning / Setup/Tuning of RF/GPRS/Hybrid (RF+GPRS) Communication infrastructure including the Network Management and Head End System(HES) for complete Automatic Metering Infrastructure (AMI) solution and the same shall be capable of meter data acquisition at user selected period, mantain time synchronism with smart energy meter and mantain communication device status and will provide visual interface to view the data/events |
| 67 | (Srl Item No. 64.00 Contd...)Notes:(a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES and the cost of the same is deemed to be included in the quoted rate for Smart Energy Meters.(b) It would be possible to run the meter in both prepaid and postpaid mode(c) Meter shall carry minimum 10 years warranty.(d) The OEM would need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. The OEM should provide complete support to MES to be able to integrate the AMI infrastructure with any IS 16444 compliant meters and connected accessories such as RF/GPRS/Hybrid Infrastructure including supporting software without any extra cost to the department. (e) During Defect liablity period of 2 years post completion of work of AMI infrastructure the contractor has to replace the Smart Meter irrespctive of the extent of fault in defective smart meter, if any in subject work. |
| 68 | Supply and Setup of Meter Data Management (MDM) system including supply and configuration of the Web based Software with following modules:(i) Meter Data Management ModuleThe meter data management module would be deemed for collecting the data from the meter and sending to DCU/server directly and vice versa based on type of communication (RF or Cellular/Hybrid), make the data available in bidirectional mode to support the currency recharge, online payment gateway, post paid billing modules, scheduling maintenance, low balance warning, quarter wise KVA allocation/tripping, tariff regulations, software customisations etc all as directed by the Engr-in-Charge with the following features:(a) 15 min instantenous data from all the meters for minimum six parameters- Cumulative Energy, Power, Current, Voltage, Power Factor and Frequency.(b) Abstract Download for Monthly and quarterly billing survey data for cumulative energy and max demand and tampering features.(ii) Multiple Payment Gateway with different Payment Modes such as Secure Mobile App/ PC Based/Swipe Machine/ Online Payment Gateway/all UPI platform/MRO based cash payment for all users assigned by BSO/GE. Gateway/Mode should be selected such that No transaction charges are levied/applicable to the admin (MES).(iii) Billing Module: Postpaid /Prepaid Billing Module:The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make the energy data/billing data available to admin to end users. The billing module would include functionaries for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required without any additional cost implication to the department. |
| 69 | (Srl Item No. 66.00 Contd...)(iv) Occupation and Vacation Module: Provision to enter admin controls for transfers/vacations. The system would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events.(v) Customer Module: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.(vi) Energy Accounting ModuleThe system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case tally with incomer EB energy meter.(vii) Communication ModuleThe system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process.(ix) Excel Export:The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution.(xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. |
| 70 | (Srl Item No. 66.00 Contd...)(xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email.Notes - The additional functional requirements of MDMS are as follows: (A) Asset Management: i) Meter Location (Apartment, shop, industry/address etc).ii) Consumer Information (Name, Account, ID etc)iii) Meter details (Meter No. 1 phase/3 phase, with or without relay etc).iv) Meter Configuration (Demand integration period, load profile capture period etc).v) GIS information (connection, feeder/transformer/pole etc)(B) Meter data:i) Schedule and on demand meter reads and pinging of meter.ii) Storage of all connected meter events and alarm. (storing of 5 years data or more via archiving)iii) Provide complete history and audit trail for all data for 30 days (configurable period)iv) Handle net metering/meters at the same premises.v) Manage at a minimum 15 minutes interval data. |
| 71 | (Srl Item No. 66.00 Contd...)(C) Data validation, Estimation and Editing (VEE): i) Registered Read Data: Daily Billiing Cycle, as well as derived billing determinants like TOU.ii) Interval Data: Variable intervals and variable units of measure.iii) Calculated Data: Derived or computed such as determinants billing and aggregated loads.iv) Event Data: Event and alarm data from meters, network equipment and MDMS itself. (D) Billing Determinants:i) Configuration multiple TOU/TOD options by customer type, day type (Weekend, Weekdays, and holidays) and by season.ii) Processing of interval data into billing determinants. a) Total consumption b) Consumption in different time blocks for TOU billing. c) Maximum demand (KW and KVA) d) Number of tamper counts e) Average power factor f) Ability for check metering, sub metering prepaid metering and net metering.(E) Exceptions:i) Capture and log data exceptions, problems and failures and send emails/SMS.ii) Generate exceptions for a) Meter tamper alerts b) Communication module health alerts c) Communication is less/more than pre-defined average consumption d) Negative consumption e) Power Outage f) Demand/Load g) Renewable Energy/EV |
| 72 | (Srl Item No. 66.00 Contd...)(F) Customer Services:i) Access to current and historical consumption and interval data, outage flags, voltage and power quality indications.ii) Email/SMS notification of configured alarms and events to selected users.iii) Web portal to provide the consumer near real time online views of Usage and Cost, Alerts and Notifications and Mobile App.(G) Analysis:i) Consumption/load profiles. a) Configurable period (hours, day, month, year etc) b) Day type (Weekend, holiday, festival wise etc) c) Tariff, customer type, or any user specified collection of meters.ii) Peak and off peak load patterns by aggregating all loads of DT/Feeder/consumer group.iii) Feeder wise energy audit.iv) Load forecasting, load research.v) Ability to configure the system to effectively visualise consumption trends, identify unusual patterns, and visualise load analysis to understand which assets are being over utilised.(vi) Analysing tamper event data. |
| 73 | (Srl Item No. 66.00 Contd...) (H) Reporting:i) Daily data collection report.ii) Usage exceptionsiii) VEE validations failures.iv) Physical meter events (install, remove, connect, disconnect) and meter resent report.v) Meter flags.vi) Meter inventory.vii) Defective meters.viii) Interface exception reports between MDM and other subsystems eg. billing, outage etc. |
| 74 | (Operation including Rectification of defects/ Repair/ Maintenance of AMI Infra during Defects Liabilit Period):Any operation including rectification of defects/repair/ Maintenance of AMI system, Software AMC, Changes in the Government tariff structure , 24 x 7 customer care support, Reports development, Software bug fixing, Trouble shooting and necessary actions, Software installation or upgradation, hosting on GCC server etc. for a period of 02 years during Defects Liability Period. The rate quoted against Phase I(A) shall deemed to included for operation and rectification of defects/repair/maintenance of AMI system during the Defects Liability Period. |
| 75 | Provision of Annual Maintenance for the 1st year after defect liability period. |
| 76 | Comprehensive maintenance of prepaid smart meter catered under Phase-I including vending system charge. They would include the following items:-(a) Software AMC: This would include necessary up-gradations in the software such as support to the chrome browser charges, android version charges, iOS version charges. These charges happen on frequent basis and the software would support all the charges.(b) Changes in the Government tariff structure: The Government tariff charges may require software upgrade. The same would be included in the AMC scope of work.(c) 24 x 7 customer care support: Ensuring adequate database backup, up-gradations in the operating system, anti-virus updates, data base upgrade etc.(d) Reports development: The additional reports as needed for the success of the project would be developed.(e) Software installation on any alternate/ backup server, if required.(f) The communication network monitoring and support.(g) Configuration of the repaired/ replaced hardware in the system.(h) Trouble shooting and necessary actions to run the system as required.(i) Software bug fixing as and when required. |
| 77 | Hosting the software to Government community cloud and management of supplied software application with standby server for all Smart Meters.Note:- The GCC location would as per the approved MEITY list. In case a CSP is removed from the panel, the contractor would migrate to a new supplier. |
| 78 | Provision of Annual Maintenance for the 2nd year after defect liability period. |
| 79 | Comprehensive maintenance of prepaid smart meter catered under Phase-I including vending system charge. They would include the following items:-(a) Software AMC: This would include necessary up-gradations in the software such as support to the chrome browser charges, android version charges, iOS version charges. These charges happen on frequent basis and the software would support all the charges.(b) Charges in the Government tariff structure: The Government tariff charges may require software upgrade. The same would be included in the AMC scope of work.(c) 24 x 7 customer care support: Ensuring adequate database backup, up-gradations in the operating system, anti-virus updates, data base upgrade etc.(d) Reports development: The additional reports as needed for the success of the project would be developed.(e) Software installation on any alternate/ backup server, if required.(f) The communication network monitoring and support.(g) Configuration of the repaired/ replaced hardware in the system.(h) Trouble shooting and necessary actions to run the system as required.(i) Software bug fixing as and when required. |
| 80 | Hosting the software to Government community cloud and management of supplied software application with standby server for all Smart Meters.Note:- The GCC location would as per the approved MEITY list. In case a CSP is removed from the panel, the contractor would migrate to a new supplier. |
| 81 | Note:- Schedule of credit (Sch 'A' Part- XVII) amount of Rs 6,587.00 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail