| 1 | Civil Work |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) |
| 4 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 6 | 5.1.3Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 13.1.1 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand) |
| 8 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m |
| 9 | Electrical Work |
| 10 | 90.15.1.1 Supply, installation, testing and commissioning of Octagonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter, thickness 3 mm, base plate dimensions of 200 x 200 x 16 mm, suitable for windspeed as per IS 875 Part III, fixed head frame including round arm luminary carriage suitable to install 4/6 luminaries in symmetrical arrangement including connector, foundation bolt 4 nos, existing RCC foundation and junction box etc., complete. 8 Meters height |
| 11 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising of thefollowing components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly asper form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays, indicationlamps, bus bar interconnection etc, detachable covers for bus bar chamber and cablealley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall notbe used for the fabrication of panel assembly. The measurments will be taken the areaof the complete sheets used for panel board including partitions, folding, shroudingetc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powdercoated (excluding base frame) |
| 13 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 14 | OD232780/2025-2026Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digitaltimer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 15 | OD232781/2025-2026Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-wayneutral links mountedon DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVCinsulated single core copper conductor cable. |
| 16 | OD232782/2025-2026Supply Conveyance and Installation of Surge protector device of IP 20 Mounting type: Screw, Voltage protection level (UP), Nominal voltage : 230V, UOC: 10KV, L-N:7KV , L-PE:7 KV,N-PE:7 KV, Nominal discharge current (8/20): 10KA, Totaldischarge current (8/20): 60 KA, Response time: <35 ns, Ta: -10-55 |
| 17 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |
| 18 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps |
| 19 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 20 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 21 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 22 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 23 | 90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 2.50 sq mm |
| 24 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke andsalt ) as required. |
| 25 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 26 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 27 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 28 | 90.12.1.12Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm |
| 29 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 30 | OD232783/2025-2026Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>3 X 4 sq. mm (19mm) |
| 31 | OD232779/2025-2026Fabrication ,supply, conveyance and installation of Granite name board indicating thecost involved, the commencement, completion and inauguration date etc |
| 32 | Connection charges - KSEB Please Enable Macros to View BoQ information |