| 1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2 | 1 or 2 Module (75mmX75mm) |
| 3 | 4 Moudle (125mmX75mm) |
| 4 | 6 Moudle (200mmX75mm) |
| 5 | 8 Module (125mmX125mm) |
| 6 | 12 Module (200mmX150mm) |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 8 | Group A |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 10 | 5/6 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | 15/16 A switch |
| 13 | 6 pin 15/16 A socket outlet |
| 14 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 16 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 17 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 18 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 19 | Group A |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 21 | Group A |
| 22 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 23 | 20 mm |
| 24 | 25 mm |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 26 | 2X10 sq. mm +1X 6 sq. mm earth wire |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, with MCB distribution board, 240 V,on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | 8 way, Double door |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 30 | Single pole |
| 31 | Single pole and neutral |
| 32 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 33 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 35 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 36 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m |
| 37 | All kinds of soil |
| 38 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 39 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar work |
| 40 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 41 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 42 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system underapproximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified |
| 43 | 2 mm thick flat |
| 44 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. |
| 45 | 40 mm dia nominal bore |
| 46 | 50 mm dia nominal bore |
| 47 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 48 | 40 mm nominal bore |
| 49 | 50 mm nominal bore |
| 50 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 51 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 52 | 3x2.5 sq.mm |
| 53 | 3x4 sq.mm |
| 54 | 3x6 sq.mm |
| 55 | Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 56 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm. |
| 57 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 58 | Supply, installation, testing and commissioning of 7.5 HP Open well submersible pump set of having head (16-30) meter, flow rate (3000-1200) LPM, size Suction X Delivery (80 X65) mm, Three phase, 440V, 50 Hz, making of cable termination etc completed as required,, Make Kirloskar, Cat.No-KOS-830+ or equivalent model of KSB/ Grundfos/ Mody/ Crompton/ CRI/ Beacon/ ABB/ Xylem |
| 59 | Supplying of PVC insulated and PVC sheathed copper conductor flat summersible cable of 1.1 KV grade of size 3C X 4 sqmm conforming to the IS694:2010 etc complete as required |
| 60 | Supply, installation , testing and commissioning of 1 HP , Direct on line starter with sheet steel enclosures suitable for 1-phase, 220V , complete set with contractor & OLR , start , stop push button with indicator lamps, voltmeter, ammeter, including mounting arragement of starter with all accesories etc. as required. Make Havells URJA- DOL submersible pump controller (Standard )- 1 Phase , Cat No. IHADOAJ1FD or equivalent model of crompton/BCH Electric |
| 61 | Supply, installation, testing and commissioning of 1.5 HP Borewell submersible pump suitable for 100 mm dia bore having head (145-45) meter, flow rate (0-52) LPM, single phase, 230V, 50 Hz, with control panel making of cable termination etc completed as required,, Make Kirloskar, Cat.No-KP4 Jalraaj UVA 30-1520 CP or equivalent model of KSB/ Grundfos/ Mody/ Crompton/ CRI/ Beacon/ ABB/ Xylem |
| 62 | Supply, installation, testing and commissioning of Monobloc pump set having minimum head (32-52) meter, discharge (8.6-4.5) LPS, 3 phase, 440V, 50 Hz making of cable termination etc completed as required,, Make Kiloskar, Cat.No. KDS-852++ or equivalent model of KSB/ Grundfos/ Mody/ Crompton/ CRI/ Beacon/ ABB/ Xylem. |
| 63 | Supplying and fixing of 40A/50A/63A, 10 KA rating, double pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make-Hager, Cat.No-NCN240N/NCN250N/NCN263N or equivalent model of Legrand/ABB. |
| 64 | Cleaning of borewell from all kinds of soil/sand for all depth, including liftup and laydown of pump set, pipe, lowering of cleaning tools, bailing out water, disposal of surplus soil/sand, providing and fixing of necessary structure for chain pully, detection of water leakage, replacing of nut/bolt if any etc. complete as required. |
| 65 | Providing and fixing of pump set having minimum head (12-26) meter, discharge (560-70) LPM, with suitable starter on hire basis for dewatering including making suitable arrangements for draining of water from the tank, complete with necessary electrical connections, suction and delivery pipes, and other associated valves, clamp etc. complete as required. This also includes the operation of pumpset during the hiring period. |
| 66 | Supply, installation, testing and commissioning of 7.5 HP, Direct on line starter with sheet steel enclosures suitable for 3-phase, 440V, complete set with contractor & OLR, start, stop push button with indicator lamps, voltmeter, ammeter, including mounting arrangement of starter with all accessories etc. as required. Make havells URJA-DOL submersible pump controller (standard) - 3 phase, CatNo.IHSDOAL1*A or equivalent model of Crompton / BCH Electric Limited. |
| 67 | Supplying of one number PVC insulated and PVC sheathed / XLPE copper conductor un armoured power cable of 650/1100 KV grade of size 3C x 2.5 sqmm etc as required. Please Enable Macros to View BoQ information |